Detecting the faint signal of continuous gravitational waves (CWs) stands as a major frontier in gravitational-wave astronomy, pushing the need for detectors whose sensitivity exceeds the standard quantum limit (SQL). Here, we propose an orbital optomechanical (OOM) sensor that exploits the sensitive coupling of an orbitally squeezed $p$-orbital Bose-Einstein condensate to spacetime distortions, enabling the detection of interferometer phase shifts induced by CWs. This sensor achieves a theoretical quantum-noise-limited sensitivity 16 dB below the SQL while reducing the required laser power by five orders of magnitude. The performance arises from a novel noise trade-off: a counter-propagating readout scheme suppresses photonic shot noise, while orbital squeezing minimizes the remaining atomic projection noise. By leveraging quantum control over atomic orbital degrees of freedom, this approach establishes a new framework for interferometric sensing with direct applications to the search for CWs and ultralight dark matter.
Squeezing atomic p-orbital condensates for detecting gravitational waves
Detecting the faint signal of continuous gravitational waves (CWs) stands as a major frontier in gravitational-wave astronomy, pushing the need for detectors whose sensitivity exceeds the standard quantum limit (SQL). Here, we propose an orbital optomechanical (OOM) sensor that exploits the sensitive coupling of an orbitally squeezed p-orbital Bose-Einstein condensate to spacetime distortions, enabling the detection of interferometer phase shifts induced by CWs. This sensor achieves a theoretical quantum-noise-limited sensitivity 16 dB below the SQL while reducing the required laser power by five orders of magnitude. The performance arises from a novel noise trade-off: a counter-propagating readout scheme suppresses photonic shot noise, while orbital squeezing minimizes the remaining atomic projection noise. By leveraging quantum control over atomic orbital degrees of freedom, this approach establishes a new framework for interferometric sensing with direct applications to the search for CWs and ultralight dark matter.
Abstract Recent advances in quantum sensing—optical clocks at 5.5 × 10 − 19 systematic uncertainty, frequency-dependent squeezing below the standard quantum limit, quantum magnetometers approaching fundamental sensitivity limits—raise a natural question: can these technologies detect gravitational waves directly, or enhance existing detectors beyond current capabilities? We show that the answer is primarily determined by the coupling mechanism between the gravitational wave and the sensor. Starting from the tidal Hamiltonian in Fermi normal coordinates, we identify three physically distinct mechanisms by which a gravitational wave couples directly to a quantum system, and derive their transducer gains within linearized general relativity and non-relativistic quantum mechanics. Internal atomic coupling (tidal distortion of electronic wavefunctions) yields a transducer gain G A = 2.4 × 10 − 20 , with vanishing first-order energy shifts for all J = 0 clock states—a ∼ 10 35 deficit relative to laser interferometry that exceeds any projected quantum enhancement. Center-of-mass coupling (Doppler shifts from geodesic motion) reaches strain sensitivities of ∼ 10 − 18 , still 10 4 above LISA requirements. Light propagation coupling (phase accumulation over macroscopic baselines) provides the enormous transducer gain that makes laser interferometry—and atom interferometry—viable. For detectors exploiting this third mechanism, we quantify how much improvement quantum sensors can provide through the detector’s noise architecture: LISA’s noise budget is predominantly classical, limiting combined quantum enhancement to E ≈ 1.04 , while ground-based detectors in the shot-noise-dominated regime achieve E = 1.6 – 2.1 . Atom interferometers exploit the same light-propagation mechanism to target the 0.01–10 Hz band between the LISA and LIGO ranges.
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.
Nearly a century after Einstein first predicted the existence of gravitational waves, a global network of Earth-based gravitational wave observatories 1-4 is seeking to directly detect this faint radiation using precision laser interferometry. Photon shot noise, due to the quantum nature of light, imposes a fundamental limit on the attometre-level sensitivity of the kilometre-scale Michelson interferometers deployed for this task. Here, we inject squeezed states to improve the performance of one of the detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) beyond the quantum noise limit, most notably in the frequency region down to 150 Hz, critically important for several astrophysical sources, with no deterioration of performance observed at any frequency. With the injection of squeezed states, this LIGO detector demonstrated the best broadband sensitivity to gravitational waves ever achieved, with important implications for observing the gravitational-wave Universe with unprecedented sensitivity.
Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.
We propose an ultrasensitive displacement measurement scheme to overcome the standard quantum limit (SQL) in the unresolved sideband cavity optomechanical system with nonlinear optomechanical coupling and squeezed light injection. By introducing the optimized quantum correlation, which is enabled by suitable choices of the squeezing angle, squeezing level, power of the probe light, and measurement angle of homodyne detection, the off-resonant displacement sensitivity reaches 6 dB below the SQL in linear optomechanical coupling. In contrast, displacement sensitivities with a coherent probe plus variational readout and squeezed probe plus fixed measurement angle (phase quadrature) are 2.6 dB and 4.6 dB below the SQL, respectively. By combining linear and quadratic optomechanical coupling, we show that the displacement sensitivity can be further improved to 9.6 dB below the SQL. Our results have potential applications in gravitational-wave detectors, quantum metrology, and the search for dark matter.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.