arXiv:2409.16264 · Optics Letters

Deployment of a transportable Yb optical lattice clock

Tobias Bothwell, Wesley Brand, Robert Fasano, Thomas G. Akin, J. D. Whalen, Tanner Grogan, Yun-Jhih Chen, Marco Pomponio, Takuma Nakamura, Benjamin Rauf, Ignacio Baldoni, Michele Giunta, Ronald Holzwarth, Craig Nelson, Archita Hati, Franklyn Quinlan, Richard W. Fox, Steven Peil, Andrew D. Ludlow

Published Jan 14, 2025• 31 citations
arXivHTMLPDF

Abstract

We report on the first deployment of a ytterbium (Yb) transportable optical lattice clock (TOLC), commercially shipping the clock 3000 km from Boulder, Colorado, to Washington DC. The system, composed of a rigidly mounted optical reference cavity, an atomic physics package, and an optical frequency comb, fully realizes an independent frequency standard for comparisons in the optical and microwave domains. The shipped Yb TOLC was fully operational within 2 days of arrival, enabling frequency comparison with a rubidium (Rb) fountain at the United States Naval Observatory (USNO). To the best of our knowledge, this represents the first deployment of a fully independent TOLC, including the frequency comb, coherently uniting the optical stability of the Yb TOLC to the microwave output of the Rb fountain.

DOI
10.1364/ol.543310

Related papers

Optical Lattice Clock with Spin-1/2 Ytterbium Atoms

N. Lemke

An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.

•Jan 1, 2012•11 citations

Compact 780-nm Rb optical clock

Zhendong Chen, Tianyu Liu, Ruoao Yang +9 more

We demonstrate a compact 780-nm rubidium optical clock, comprising an optical-frequency standard and an optical-frequency comb, with a total optical volume of 11.6 liters. Unlike the 778-nm rubidium atomic clocks based on two-photon transitions, the laser frequency in our system was stabilized to the hyperfine transition of ${}^{87}\mathrm{Rb}$ ${5}^{2}{\mathrm{S}}_{1/2}$ (F = 2) \ensuremath{\rightarrow} ${5}^{2}{\mathrm{P}}_{3/2}$ (F\ensuremath{'} = 3) using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides higher signal-to-noise ratio and sensitivity. After correcting for systematic perturbations, the absolute frequency was measured to be 384 228 115 200.7(2.7) kHz. A nearly 300-MHz microwave signal, whose phase exactly tracked that of the optical-frequency standard, was generated via the optical-frequency comb, yielding a frequency instability of 1.91 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}13}$ at 1 s and 5.29 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}14}$ at 1000 s in the electronic domain. The reproducibility was measured to be 3.66 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ by comparing results from four independent daily measurements, each conducted following a complete system shutdown and restart. This is among the most precise frequency stabilization results for the first-excited-state transition of alkali metal atoms to date, and represents an optical clock based on this transition. This work offers a promising approach for the development of portable optical clocks.

arXiv:2501.01826•Physical Review Applied•Jan 2, 2026•6 citations

Optical frequency metrology with ytterbium and strontium optical lattice clocks

Feng-Lei Hong, Masami Yasuda, Takuya Kohno +6 more

We report on the development of an ytterbium (171Yb) and a strontium (87Sr) optical lattice clock at the National Metrology Institute of Japan (NMIJ). The result of absolute frequency measurement of the171Yb lattice clock is shown. We also report on narrow-linewidth fiber-based frequency combs that are used not only to measure the absolute frequency of the optical lattice clocks but also to servo control the frequency of the lasers for cooling and trapping Yb and Sr atoms.

URSI General Assembly and Scientific Symposium•Aug 1, 2011•0 citations

Towards a Transportable Optical Frequency Standard Based on a Single Yb+ Ion

Y. H. Zheng, Yiting Chen, S. N. Miao +8 more

SummaryThe optical clock based on trapped ions has attracted great interest due to the important significance in fundamental physics and application prospects in metrology of time and frequency. The ytterbium ion has unique advantages in developing transportable and miniaturized optical clocks because it has long storage time and its related laser system is compact. In addition, the171Yb+ion has two clock transition lines, which can perform frequency self-comparison. This paper mainly introduces the progress in the development of the transportable optical clock system based on the single171Yb+ion at Tsinghua University, China. A transportable physical package, including the vacuum system, optic system and imaging system is presented and implemented to automatically detect the presence of trapped ion.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 12, 2025•1 citation

Physics package validation and system integration for a low-SWaP, portable cold multi-ytterbium ion 12.6 GHz microwave clock

M. A. Trigatzis, Ulas Sabahattin Gokay, Martin Knapp +6 more

Compact atomic clocks provide the stable, traceable timing required for 5G/6G telecom networks, for resilient operation of critical infrastructure including power grids, data centres and financial systems, and for maintaining accurate synchronisation during GNSS interruptions or outages. Microwave clocks based on caesium beam tubes have been the industry-standard rack-mounted clock for many years but are now outperformed in short-to-midterm instability by emerging technologies. Vapour cell clocks suffer from long-term drift which must be calibrated out periodically and on startup. This limits their use for long-term holdover and in applications where the device needs to operate after a cold start. Additionally, optical clocks require a narrow-linewidth clock laser and optical frequency comb. The ytterbium ion microwave clock developed at the National Physical Laboratory (NPL) does not require these subsystems and combines this relative simplicity with the benefits of laser cooling (long-term stability, accuracy). In this paper, we describe an ion trap physics package design where its functionality has been evaluated in a benchtop clock and forms the basis of a new design for a compact, transportable clock. We describe the operation and performance of the benchtop clock, demonstrating a short-term fractional frequency instability of 1.4 × 10 − 12 /√τ. The design for a new transportable clock based on this new physics package is detailed, as are the validation tests of other key subsystems.

•Jun 18, 2026•0 citations

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•3 citations
We report on the first deployment of a ytterbium (Yb) transportable optical lattice clock (TOLC), commercially shipping the clock 3000 km from Boulder, Colorado, to Washington DC. The system, composed of a rigidly mounted optical reference cavity, an atomic physics package, and an optical frequency comb, fully realizes an independent frequency standard for comparisons in the optical and microwave domains. The shipped Yb TOLC was fully operational within 2 days of arrival, enabling frequency comparison with a rubidium (Rb) fountain at the United States Naval Observatory (USNO). To the best of our knowledge, this represents the first deployment of a fully independent TOLC, including the frequency comb, coherently uniting the optical stability of the Yb TOLC to the microwave output of the Rb fountain.
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.
We demonstrate a compact 780-nm rubidium optical clock, comprising an optical-frequency standard and an optical-frequency comb, with a total optical volume of 11.6 liters. Unlike the 778-nm rubidium atomic clocks based on two-photon transitions, the laser frequency in our system was stabilized to the hyperfine transition of 87Rb{}^{87}\mathrm{Rb}87Rb 52S1/2{5}^{2}{\mathrm{S}}_{1/2}52S1/2​ (F = 2) \ensuremath{\rightarrow} 52P3/2{5}^{2}{\mathrm{P}}_{3/2}52P3/2​ (F\ensuremath{'} = 3) using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides higher signal-to-noise ratio and sensitivity. After correcting for systematic perturbations, the absolute frequency was measured to be 384 228 115 200.7(2.7) kHz. A nearly 300-MHz microwave signal, whose phase exactly tracked that of the optical-frequency standard, was generated via the optical-frequency comb, yielding a frequency instability of 1.91 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}13}$ at 1 s and 5.29 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}14}$ at 1000 s in the electronic domain. The reproducibility was measured to be 3.66 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ by comparing results from four independent daily measurements, each conducted following a complete system shutdown and restart. This is among the most precise frequency stabilization results for the first-excited-state transition of alkali metal atoms to date, and represents an optical clock based on this transition. This work offers a promising approach for the development of portable optical clocks.
SummaryThe optical clock based on trapped ions has attracted great interest due to the important significance in fundamental physics and application prospects in metrology of time and frequency. The ytterbium ion has unique advantages in developing transportable and miniaturized optical clocks because it has long storage time and its related laser system is compact. In addition, the171Yb+ion has two clock transition lines, which can perform frequency self-comparison. This paper mainly introduces the progress in the development of the transportable optical clock system based on the single171Yb+ion at Tsinghua University, China. A transportable physical package, including the vacuum system, optic system and imaging system is presented and implemented to automatically detect the presence of trapped ion.
Compact atomic clocks provide the stable, traceable timing required for 5G/6G telecom networks, for resilient operation of critical infrastructure including power grids, data centres and financial systems, and for maintaining accurate synchronisation during GNSS interruptions or outages. Microwave clocks based on caesium beam tubes have been the industry-standard rack-mounted clock for many years but are now outperformed in short-to-midterm instability by emerging technologies. Vapour cell clocks suffer from long-term drift which must be calibrated out periodically and on startup. This limits their use for long-term holdover and in applications where the device needs to operate after a cold start. Additionally, optical clocks require a narrow-linewidth clock laser and optical frequency comb. The ytterbium ion microwave clock developed at the National Physical Laboratory (NPL) does not require these subsystems and combines this relative simplicity with the benefits of laser cooling (long-term stability, accuracy). In this paper, we describe an ion trap physics package design where its functionality has been evaluated in a benchtop clock and forms the basis of a new design for a compact, transportable clock. We describe the operation and performance of the benchtop clock, demonstrating a short-term fractional frequency instability of 1.4 × 10 − 12 /√τ. The design for a new transportable clock based on this new physics package is detailed, as are the validation tests of other key subsystems.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.