Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2406.01185

Driving a Josephson Traveling Wave Parametric Amplifier into chaos: effects of a non-sinusoidal current-phase relation

Claudio Guarcello, C. Barone, Giovanni Carapella, V. Granata, Giovanni Filatrella, Andrea Giachero, S. Pagano

Published Jun 3, 2024• 0 citations
arXivHTMLPDF

Abstract

In this work, we develop a comprehensive numerical analysis of the dynamic response of a Josephson Traveling Wave Parametric Amplifier (JTWPA) by varying the driving parameters, with a focus on the pathways leading to chaotic behavior. By tuning the working conditions, we capture the broad spectrum of dynamical regimes accessible to JTWPAs, delineating the settings under which transition to chaos occurs. Furthermore, we extend our investigation to device formed by junctions characterized by a non--sinusoidal current phase relation (CPR) and exploring the impact of its shape on the amplifier's performance. Through the study of gain characteristics, Poincaré sections, and Fourier spectra, we provide an in-depth understanding of how non-linearity and CPR nonsinusoidality influence the JTWPAs' operational effectiveness and stability. This investigation offers insights into optimizing the device designs for enhanced performance and robustness against chaotic disruptions, in order to establish a framework for predicting and controlling JTWPA behavior in practical applications. This effort will pave the way for the development of devices with tailored dynamic responses and for advancements in quantum computing and precision measurement technologies, where stability and high fidelity are of paramount importance.

DOI
10.48550/arxiv.2406.01185

Related papers

Driving a Josephson Traveling Wave Parametric Amplifier into chaos: Effects of a non-sinusoidal current–phase relation

Claudio Guarcello, C. Barone, Giovanni Carapella +4 more

We tackled the numerical analysis of the dynamic response of a Josephson Traveling Wave Parametric Amplifier (JTWPA) by varying the driving parameters, with a focus on the pathways leading to chaotic behavior. By tuning the working conditions, we explore the broad spectrum of dynamical regimes accessible to JTWPAs, delineating the conditions under which transition to chaos occurs. Furthermore, we extend our investigation to junctions characterized by a non-sinusoidal current phase relation (CPR) and explore the consequences on the amplifier’s performance. Through the study of gain characteristics, Poincaré sections, and Fourier spectra, we provide an in-depth understanding of how CPR nonlinearity and nonsinusoidality influence the operational effectiveness and stability of JTWPAs. This investigation offers insights into optimizing the device for enhanced performance and robustness against chaotic disruptions, in order to establish a framework for predicting and controlling JTWPA behavior in practical applications. In fact, we identify the regions in the parameter space where the input signal is maximally amplified without excessive noise or undesired harmonics. This effort paves the way for the development of devices with tailored dynamic responses and for advancements in quantum computing and precision measurement technologies, where stability and high fidelity are of paramount importance.

Chaos Solitons & Fractals•Oct 10, 2024•8 citations

Properties of Josephson Traveling Wave Parametric Amplifier With a Non-Sinusoidal Current-Phase Relation and Resonant Phase Matching

Claudio Guarcello, C. Barone, Giovanni Carapella +3 more

A comprehensive numerical analysis of the dynamical response of Josephson Traveling Wave Parametric Amplifiers (JTWPA) under varying driving conditions is presented. The primary goal is to examine the effects of a current–phase relation (CPR) incorporating a second-harmonic contribution. The analysis further investigates how parameters such as pump intensity, signal frequency, and DC bias current influence the transition to chaos. The results reveal a wide range of dynamical regimes in JTWPAs, offering insights into optimizing device performance and stability. Notably, the shape of the CPR is shown to have a significant impact on the operational effectiveness and stability of JTWPAs. To obtain results closer to real devices, numerical modeling of JTWPAs implementing Resonant Phase Matching (RPM) circuitry has been performed. We have verified that the introduction of RPM allows a significant increase in the amplifier gain also in the case of non-sinusoidal CPR. These findings may have important implications for the development of next-generation JTWPAs, which are essential components in quantum computing and precision measurement applications.

IEEE Transactions on Applied Superconductivity•Jan 27, 2026•0 citations

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Claudio Guarcello, Felix Ahrens, Guerino Avallone +40 more

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation—effects that are not easily accommodated by simplistic linearized approaches.

arXiv:2403.01597•IEEE Transactions on Applied Superconductivity•Feb 20, 2024•6 citations

Effect of a second-harmonic current–phase relation on the behavior of a Josephson traveling-wave parametric amplifier

Claudio Guarcello, C. Barone, Giovanni Carapella +3 more

We numerically investigate the behavior of a Josephson traveling-wave parametric amplifier assuming a current–phase relation with a second-harmonic contribution. We find that varying the weight of harmonic terms in the Josephson current affects the gain profile. The analysis of gain characteristics, phase-space portraits, Poincaré sections, and Fourier spectra demonstrates that the nonsinusoidal contribution influences the operating mode and stability of the device. In particular, we identify the optimal weighting of harmonic contributions that maximizes amplification, achieving gains up to ∼13 dB in a device without dispersion engineering.

arXiv:2502.00804•Applied Physics Letters•Apr 21, 2025•4 citations

Designing Josephson Traveling-Wave Parametric Amplifiers: EM-Circuit Cosimulation and Experimental Validation

Likai Yang, Jennifer Wang, Daryoush Shiri +6 more

The development of large-scale superconducting quantum computers critically depends on the accurate readout of qubit states. To enable this, cryogenic parametric amplifiers have been proposed and developed, and have since found widespread use in small-signal detection applications. Among various amplifier architectures, Josephson traveling-wave parametric amplifiers (JTWPAs) are widely adopted due to their broad bandwidth, high saturation power, and compatibility with superconducting qubits. In this work, we present a design workflow of JTWPAs based on a co-simulation approach combining electromagnetic (EM) and circuit-level simulation. We apply this method to a uniform JTWPA, comparing our simulation results with experimental data. To mitigate the challenge of constructing lumped element circuit models usually used in conventional simulation method, we directly perform full EM analysis of the device to accurately determine its linear response. The extracted S parameters are then fed into a nonlinear harmonic balance simulator with Josephson junctions modeled as circuit elements. By doing so, the linear and gain properties of the JTWPA are extracted. Different factors that impact device performance including gain compression, phase matching, and fabrication imperfections are further investigated and modeled. A good agreement between simulation and measurements is identified, establishing the effectiveness of our approach in designing quantum parametric amplifiers.

IEEE Transactions on Applied Superconductivity•May 20, 2026•0 citations

Numerical analysis of dynamical behavior in Josephson junctions with non-sinusoidal current-phase relations

Liangliang Yang, HE Kaiyong, Genting Dai +5 more

Josephson junction, as the core nonlinear element underpinning superconducting electronics, is characterized by its current-phase relation (CPR), which fundamentally determines the dynamical properties and functional capabilities of superconducting quantum devices. Traditional Josephson junctions typically exhibit a traditional sinusoidal CPR; however, the junctions characterized by non-sinusoidal CPR have recently attracted considerable attention due to their distinctive physical properties and promising quantum device applications. In this work, a numerical model tailored specifically for junctions exhibiting non-sinusoidal CPR is developed by integrating experimentally measured current-voltage (I-V ) characteristics from Nb/Al-AlOx/Nb junctions into a resistively and capacitively shunted junction (RCSJ) framework. By leveraging this refined model, the influence of CPR skewness on Josephson junction dynamics is systematically investigated. Our results indicate that in underdamped junctions, the critical current significantly diminishes with the increase of CPR skewness, a behavior reminiscent of the adjustable critical currents typically observed in DC superconducting quantum interference devices (SQUIDs). Conversely, in overdamped junctions, the influence of CPR skewness on the I-V characteristics is found to be negligible. However, our numerical simulations under microwave irradiation indicate that nonsinusoidal CPRs readily promote the emergence of half-integer Shapiro steps in overdamped junctions, thereby establishing CPR skewness as a plausible microscopic origin for this phenomenon. In addition, the advanced design system (ADS) simulations is employed to model nonlinear resonators and DC SQUID circuits, offering a detailed investigation into how nonsinusoidal CPRs modulate the Josephson inductance and magnetic flux response. Our findings reveal that engineering the CPR of Josephson junctions provides substantial flexibility in the design of superconducting qubits, parametric amplifiers, and non-magnetic nonreciprocal devices. This tunability underscores significant opportunities for developing next-generation superconducting electronic components. The Josephson junctions with engineered CPR offer expanded functionality for superconducting quantum technologies. This study suggests that customized CPR can enhance control over the dynamical behavior of junctions, and promote the optimized designs of superconducting qubits, parametric amplifiers, and nonmagnetic nonreciprocal devices.

Acta Physica Sinica•Jan 1, 2025•0 citations
In this work, we develop a comprehensive numerical analysis of the dynamic response of a Josephson Traveling Wave Parametric Amplifier (JTWPA) by varying the driving parameters, with a focus on the pathways leading to chaotic behavior. By tuning the working conditions, we capture the broad spectrum of dynamical regimes accessible to JTWPAs, delineating the settings under which transition to chaos occurs. Furthermore, we extend our investigation to device formed by junctions characterized by a non--sinusoidal current phase relation (CPR) and exploring the impact of its shape on the amplifier's performance. Through the study of gain characteristics, Poincaré sections, and Fourier spectra, we provide an in-depth understanding of how non-linearity and CPR nonsinusoidality influence the JTWPAs' operational effectiveness and stability. This investigation offers insights into optimizing the device designs for enhanced performance and robustness against chaotic disruptions, in order to establish a framework for predicting and controlling JTWPA behavior in practical applications. This effort will pave the way for the development of devices with tailored dynamic responses and for advancements in quantum computing and precision measurement technologies, where stability and high fidelity are of paramount importance.
We tackled the numerical analysis of the dynamic response of a Josephson Traveling Wave Parametric Amplifier (JTWPA) by varying the driving parameters, with a focus on the pathways leading to chaotic behavior. By tuning the working conditions, we explore the broad spectrum of dynamical regimes accessible to JTWPAs, delineating the conditions under which transition to chaos occurs. Furthermore, we extend our investigation to junctions characterized by a non-sinusoidal current phase relation (CPR) and explore the consequences on the amplifier’s performance. Through the study of gain characteristics, Poincaré sections, and Fourier spectra, we provide an in-depth understanding of how CPR nonlinearity and nonsinusoidality influence the operational effectiveness and stability of JTWPAs. This investigation offers insights into optimizing the device for enhanced performance and robustness against chaotic disruptions, in order to establish a framework for predicting and controlling JTWPA behavior in practical applications. In fact, we identify the regions in the parameter space where the input signal is maximally amplified without excessive noise or undesired harmonics. This effort paves the way for the development of devices with tailored dynamic responses and for advancements in quantum computing and precision measurement technologies, where stability and high fidelity are of paramount importance.
A comprehensive numerical analysis of the dynamical response of Josephson Traveling Wave Parametric Amplifiers (JTWPA) under varying driving conditions is presented. The primary goal is to examine the effects of a current–phase relation (CPR) incorporating a second-harmonic contribution. The analysis further investigates how parameters such as pump intensity, signal frequency, and DC bias current influence the transition to chaos. The results reveal a wide range of dynamical regimes in JTWPAs, offering insights into optimizing device performance and stability. Notably, the shape of the CPR is shown to have a significant impact on the operational effectiveness and stability of JTWPAs. To obtain results closer to real devices, numerical modeling of JTWPAs implementing Resonant Phase Matching (RPM) circuitry has been performed. We have verified that the introduction of RPM allows a significant increase in the amplifier gain also in the case of non-sinusoidal CPR. These findings may have important implications for the development of next-generation JTWPAs, which are essential components in quantum computing and precision measurement applications.
Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation—effects that are not easily accommodated by simplistic linearized approaches.
We numerically investigate the behavior of a Josephson traveling-wave parametric amplifier assuming a current–phase relation with a second-harmonic contribution. We find that varying the weight of harmonic terms in the Josephson current affects the gain profile. The analysis of gain characteristics, phase-space portraits, Poincaré sections, and Fourier spectra demonstrates that the nonsinusoidal contribution influences the operating mode and stability of the device. In particular, we identify the optimal weighting of harmonic contributions that maximizes amplification, achieving gains up to ∼13 dB in a device without dispersion engineering.
The development of large-scale superconducting quantum computers critically depends on the accurate readout of qubit states. To enable this, cryogenic parametric amplifiers have been proposed and developed, and have since found widespread use in small-signal detection applications. Among various amplifier architectures, Josephson traveling-wave parametric amplifiers (JTWPAs) are widely adopted due to their broad bandwidth, high saturation power, and compatibility with superconducting qubits. In this work, we present a design workflow of JTWPAs based on a co-simulation approach combining electromagnetic (EM) and circuit-level simulation. We apply this method to a uniform JTWPA, comparing our simulation results with experimental data. To mitigate the challenge of constructing lumped element circuit models usually used in conventional simulation method, we directly perform full EM analysis of the device to accurately determine its linear response. The extracted S parameters are then fed into a nonlinear harmonic balance simulator with Josephson junctions modeled as circuit elements. By doing so, the linear and gain properties of the JTWPA are extracted. Different factors that impact device performance including gain compression, phase matching, and fabrication imperfections are further investigated and modeled. A good agreement between simulation and measurements is identified, establishing the effectiveness of our approach in designing quantum parametric amplifiers.
Josephson junction, as the core nonlinear element underpinning superconducting electronics, is characterized by its current-phase relation (CPR), which fundamentally determines the dynamical properties and functional capabilities of superconducting quantum devices. Traditional Josephson junctions typically exhibit a traditional sinusoidal CPR; however, the junctions characterized by non-sinusoidal CPR have recently attracted considerable attention due to their distinctive physical properties and promising quantum device applications. In this work, a numerical model tailored specifically for junctions exhibiting non-sinusoidal CPR is developed by integrating experimentally measured current-voltage (I-V ) characteristics from Nb/Al-AlOx/Nb junctions into a resistively and capacitively shunted junction (RCSJ) framework. By leveraging this refined model, the influence of CPR skewness on Josephson junction dynamics is systematically investigated. Our results indicate that in underdamped junctions, the critical current significantly diminishes with the increase of CPR skewness, a behavior reminiscent of the adjustable critical currents typically observed in DC superconducting quantum interference devices (SQUIDs). Conversely, in overdamped junctions, the influence of CPR skewness on the I-V characteristics is found to be negligible. However, our numerical simulations under microwave irradiation indicate that nonsinusoidal CPRs readily promote the emergence of half-integer Shapiro steps in overdamped junctions, thereby establishing CPR skewness as a plausible microscopic origin for this phenomenon. In addition, the advanced design system (ADS) simulations is employed to model nonlinear resonators and DC SQUID circuits, offering a detailed investigation into how nonsinusoidal CPRs modulate the Josephson inductance and magnetic flux response. Our findings reveal that engineering the CPR of Josephson junctions provides substantial flexibility in the design of superconducting qubits, parametric amplifiers, and non-magnetic nonreciprocal devices. This tunability underscores significant opportunities for developing next-generation superconducting electronic components. The Josephson junctions with engineered CPR offer expanded functionality for superconducting quantum technologies. This study suggests that customized CPR can enhance control over the dynamical behavior of junctions, and promote the optimized designs of superconducting qubits, parametric amplifiers, and nonmagnetic nonreciprocal devices.