Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2405.04642

First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility

G. Bratrud, Samantha M. Lewis, K. Anyang, A. Colón Cesaní, T. A. Dyson, Hannah Magoon, D. Sabhari, Gabriel Spahn, Wagner, G., R. Gualtieri, Noah Kurinsky, R. Linehan, R. McDermott, Sara Sussman, Dylan J. Temples, Sho Uemura, C. Bathurst, Gustavo I. Cancelo, R. Chen, Aaron S. Chou, Israel Hernandez, M. Hollister, Lauren Hsu, James, C., K. T. Kennard, Rakshya Khatiwada, P. Lukens, V. Novati, N. Raha, Shovik Ray, R. Ren, Rodriguez, A., B. Schmidt, Kelly Stifter, Jaejun Yu, D. Baxter, Enectali Figueroa-Feliciano, D. Bowring

Published May 7, 2024• 0 citations
arXivHTMLPDF

Abstract

We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

DOI
10.48550/arxiv.2405.04642

Related papers

Measurement of correlated charge noise in superconducting qubits at an underground facility

G. Bratrud, Samantha M. Lewis, K. Anyang +35 more

Abstract The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4 π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $$0.1{9}_{-0.03}^{+0.04}$$ 0.1 9 − 0.03 + 0.04 mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

Nature Communications•Nov 11, 2025•2 citations

Evaluating radiation impact on transmon qubits in above and underground facilities

Francesco De Dominicis, Tanay Roy, Ambra Mariani +20 more

Abstract Superconducting qubits can be sensitive to energy deposits caused by cosmic rays and ambient radioactivity. While previous studies have explored correlated effects in time and space due to cosmic ray interactions, we present the first direct comparison of a transmon qubit’s performance measured at two distinct sites: the above-ground SQMS facility (Fermilab, US) and the deep-underground Gran Sasso Laboratory (Italy). Despite the stark difference in radiation levels, we observe a similar average qubit relaxation time of approximately 80 microseconds at both locations. To investigate radiation-induced events, we employ a fast decay detection protocol, comparing the relative rates of events between the two environments. Although intrinsic noise remains the dominant source of errors in superconducting qubits, our analysis revealed a significant excess of radiation-induced events for high-coherence transmon qubits operated above-ground. Finally, using γ -ray sources with increasing activity levels, we evaluate the qubit response in a controlled low-background environment.

EPJ Quantum Technology•Mar 13, 2026•1 citation

First Operation of Superconducting Qubits as Particle Detectors

Camilla Bonomo, Mustafa Bal, N. Casali +21 more

Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.

•Mar 20, 2026•0 citations

Real-Time Detection of Charge Jumps in Superconducting Qubits with a Convolutional Neural Network

Daniel Gaytan-Villarreal, Peter Meiring, Daniel Baxter +6 more

Ionizing radiation from cosmic rays and gammas can induce discontinuous jumps in the environmental charge of superconducting qubits (charge jumps), causing correlated errors that challenge fault-tolerant quantum computing while simultaneously providing a detection signature for quantum sensing applications. Current detection methods operate offline, introducing latency incompatible with in-the-loop qubit control. In this paper, an online detector of charge jumps for superconducting qubits, based on a dilated causal convolutional neural network (DCCNN) designed for in-the-loop deployment on the Quantum Instrumentation Control Kit (QICK) platform, is presented. The network is trained on synthetic Ramsey tomography scans generated from qubit templates measured at the Northwestern Experimental Underground Site (NEXUS) at Fermilab, and translated to FPGA firmware via hls4ml with ap_fixed$\langle 16,6 \rangle$ quantization, reaching a per-inference latency of $ 32.0 μ$s on the Zynq UltraScale+ RFSoC ZCU216. At this operating point the DCCNN matches the detection efficiency of the established offline $χ^2$ algorithm ($0.843 \pm 0.022$ vs. $0.868 \pm 0.007$ on $|Δq| \in [0.1, 0.5] e$ at matched false-positive rate), while requiring no per-qubit hyperparameter tuning. This shifts charge-jump detection from a post-hoc diagnostic to a control-loop primitive, enabling adaptive protocols that respond to radiation-induced events in situ, with applications to quantum-computing error mitigation and to the use of superconducting qubits as particle detectors.

quant-pharXiv:2607.14293•Jul 17, 2026•0 citations

Abatement of ionizing radiation for superconducting quantum devices

B. Loer, P. M. Harrington, Brian C. Archambault +15 more

Abstract Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.

arXiv:2403.01032•Journal of Instrumentation•Sep 1, 2024•11 citations

Radiopurity material assays and radiation exposure projections for superconducting qubit measurements at SNOLAB

Y. Ahmed, B. Binoy, R. Bunker +21 more

Interactions of cosmic rays and other forms of ionizing radiation pose a significant challenge to the reliable operation of state-of-the-art quantum devices and error correction in quantum computing based on superconducting circuits which are typically fabricated on semiconductor substrates. Shielded by 2 km of rock overburden, the Cryogenic Underground TEst facility (CUTE) at SNOLAB provides a unique ultra-low radiation environment to probe the performance of quantum technologies with a particular interest in quantum coherence studies. In this article, we present the findings of an extensive material assaying program in preparation for the first underground operation of superconducting qubits at SNOLAB. The radioactivity levels identified by the material assays enter a thorough Monte Carlo study based on the Geant4 particle physics tracking code. From these simulations, we estimate the rates of energy deposits from radiogenic sources expected for a quantum-device assembly operated in the CUTE facility. We further characterize the spectral components of the projected background and identify the dominant particle interaction types. Finally, we outline how crystal dynamics simulations using the G4CMP solid-state physics extension for Geant4 can inform the community-wide efforts to identify effective strategies to mitigate the effects of high-energy particle impacts.

physics.ins-detCross-listedarXiv:2607.16151•Jul 20, 2026•0 citations
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4πππ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19−0.03+0.04^{+0.04}_{-0.03}−0.03+0.04​ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
Abstract The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4 π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19−0.03+0.040.1{9}_{-0.03}^{+0.04}0.19−0.03+0.04​ 0.1 9 − 0.03 + 0.04 mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
Abstract Superconducting qubits can be sensitive to energy deposits caused by cosmic rays and ambient radioactivity. While previous studies have explored correlated effects in time and space due to cosmic ray interactions, we present the first direct comparison of a transmon qubit’s performance measured at two distinct sites: the above-ground SQMS facility (Fermilab, US) and the deep-underground Gran Sasso Laboratory (Italy). Despite the stark difference in radiation levels, we observe a similar average qubit relaxation time of approximately 80 microseconds at both locations. To investigate radiation-induced events, we employ a fast decay detection protocol, comparing the relative rates of events between the two environments. Although intrinsic noise remains the dominant source of errors in superconducting qubits, our analysis revealed a significant excess of radiation-induced events for high-coherence transmon qubits operated above-ground. Finally, using γ -ray sources with increasing activity levels, we evaluate the qubit response in a controlled low-background environment.
Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.
Ionizing radiation from cosmic rays and gammas can induce discontinuous jumps in the environmental charge of superconducting qubits (charge jumps), causing correlated errors that challenge fault-tolerant quantum computing while simultaneously providing a detection signature for quantum sensing applications. Current detection methods operate offline, introducing latency incompatible with in-the-loop qubit control. In this paper, an online detector of charge jumps for superconducting qubits, based on a dilated causal convolutional neural network (DCCNN) designed for in-the-loop deployment on the Quantum Instrumentation Control Kit (QICK) platform, is presented. The network is trained on synthetic Ramsey tomography scans generated from qubit templates measured at the Northwestern Experimental Underground Site (NEXUS) at Fermilab, and translated to FPGA firmware via hls4ml with ap_fixed⟨16,6⟩\langle 16,6 \rangle⟨16,6⟩ quantization, reaching a per-inference latency of $ 32.0 μ$s on the Zynq UltraScale+ RFSoC ZCU216. At this operating point the DCCNN matches the detection efficiency of the established offline χ2χ^2χ2 algorithm (0.843±0.0220.843 \pm 0.0220.843±0.022 vs. 0.868±0.0070.868 \pm 0.0070.868±0.007 on ∣Δq∣∈[0.1,0.5]e|Δq| \in [0.1, 0.5] e∣Δq∣∈[0.1,0.5]e at matched false-positive rate), while requiring no per-qubit hyperparameter tuning. This shifts charge-jump detection from a post-hoc diagnostic to a control-loop primitive, enabling adaptive protocols that respond to radiation-induced events in situ, with applications to quantum-computing error mitigation and to the use of superconducting qubits as particle detectors.
Abstract Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.
Interactions of cosmic rays and other forms of ionizing radiation pose a significant challenge to the reliable operation of state-of-the-art quantum devices and error correction in quantum computing based on superconducting circuits which are typically fabricated on semiconductor substrates. Shielded by 2 km of rock overburden, the Cryogenic Underground TEst facility (CUTE) at SNOLAB provides a unique ultra-low radiation environment to probe the performance of quantum technologies with a particular interest in quantum coherence studies. In this article, we present the findings of an extensive material assaying program in preparation for the first underground operation of superconducting qubits at SNOLAB. The radioactivity levels identified by the material assays enter a thorough Monte Carlo study based on the Geant4 particle physics tracking code. From these simulations, we estimate the rates of energy deposits from radiogenic sources expected for a quantum-device assembly operated in the CUTE facility. We further characterize the spectral components of the projected background and identify the dominant particle interaction types. Finally, we outline how crystal dynamics simulations using the G4CMP solid-state physics extension for Geant4 can inform the community-wide efforts to identify effective strategies to mitigate the effects of high-energy particle impacts.