Radiopurity material assays and radiation exposure projections for superconducting qubit measurements at SNOLAB

Y. Ahmed, B. Binoy, R. Bunker, D. Chauhan, P. Delsing, R. Germond, J. Hall, Z. Hong, A. Iqbal, V. Iyer, A. Klepikova, A. Kubik, S. P. Mantry, A. C. Masuskapoe, C. C. Monk, G. Peng, P. Qin, W. Rau, T. Reynolds, M. Stukel, C. M. Wilson, B. Zatschler, S. Zatschler, A. Zuniga

physics.ins-detquant-phSubmitted Jul 17, 2026• Announced Jul 20, 2026• 0 citations
arXivHTMLPDF

Abstract

Interactions of cosmic rays and other forms of ionizing radiation pose a significant challenge to the reliable operation of state-of-the-art quantum devices and error correction in quantum computing based on superconducting circuits which are typically fabricated on semiconductor substrates. Shielded by 2 km of rock overburden, the Cryogenic Underground TEst facility (CUTE) at SNOLAB provides a unique ultra-low radiation environment to probe the performance of quantum technologies with a particular interest in quantum coherence studies. In this article, we present the findings of an extensive material assaying program in preparation for the first underground operation of superconducting qubits at SNOLAB. The radioactivity levels identified by the material assays enter a thorough Monte Carlo study based on the Geant4 particle physics tracking code. From these simulations, we estimate the rates of energy deposits from radiogenic sources expected for a quantum-device assembly operated in the CUTE facility. We further characterize the spectral components of the projected background and identify the dominant particle interaction types. Finally, we outline how crystal dynamics simulations using the G4CMP solid-state physics extension for Geant4 can inform the community-wide efforts to identify effective strategies to mitigate the effects of high-energy particle impacts.

Comments
44 pages, 11 figures, 15 tables including appendices. To be submitted to the Journal of Instrumentation

Related papers

Abatement of ionizing radiation for superconducting quantum devices

B. Loer, P. M. Harrington, Brian C. Archambault +15 more

Abstract Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.

arXiv:2403.01032•Journal of Instrumentation•Sep 1, 2024•11 citations

Evaluating Radiation Impact on Superconducting Transmon Qubits in Above and Underground Facilities

Tanay Roy, Francesco De Dominicis, Ambra Mariani +18 more

Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].

•Sep 20, 2024•0 citations

Measurement of correlated charge noise in superconducting qubits at an underground facility

G. Bratrud, Samantha M. Lewis, K. Anyang +35 more

Abstract The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4 π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $$0.1{9}_{-0.03}^{+0.04}$$ 0.1 9 − 0.03 + 0.04 mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

Nature Communications•Nov 11, 2025•2 citations

Evaluating radiation impact on transmon qubits in above and underground facilities

Francesco De Dominicis, Tanay Roy, Ambra Mariani +20 more

Abstract Superconducting qubits can be sensitive to energy deposits caused by cosmic rays and ambient radioactivity. While previous studies have explored correlated effects in time and space due to cosmic ray interactions, we present the first direct comparison of a transmon qubit’s performance measured at two distinct sites: the above-ground SQMS facility (Fermilab, US) and the deep-underground Gran Sasso Laboratory (Italy). Despite the stark difference in radiation levels, we observe a similar average qubit relaxation time of approximately 80 microseconds at both locations. To investigate radiation-induced events, we employ a fast decay detection protocol, comparing the relative rates of events between the two environments. Although intrinsic noise remains the dominant source of errors in superconducting qubits, our analysis revealed a significant excess of radiation-induced events for high-coherence transmon qubits operated above-ground. Finally, using γ -ray sources with increasing activity levels, we evaluate the qubit response in a controlled low-background environment.

EPJ Quantum Technology•Mar 13, 2026•1 citation

Disentangling the sources of ionizing radiation in superconducting qubits

L. Cardani, I. Colantoni, Angelo Cruciani +27 more

Abstract Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of radioactivity present in a typical laboratory environment (from muons, neutrons, and $$\gamma $$ γ -rays emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly and operation of state-of-the-art superconducting qubits. We present a GEANT-4 based simulation to predict the rate of impacts and the amount of energy released in a qubit chip from each of the mentioned sources. We finally propose mitigation strategies for the operation of next-generation qubits in a radio-pure environment.

arXiv:2211.13597•The European Physical Journal C•Jan 31, 2023•24 citations

First Operation of Superconducting Qubits as Particle Detectors

Camilla Bonomo, Mustafa Bal, N. Casali +21 more

Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.

•Mar 20, 2026•0 citations
Interactions of cosmic rays and other forms of ionizing radiation pose a significant challenge to the reliable operation of state-of-the-art quantum devices and error correction in quantum computing based on superconducting circuits which are typically fabricated on semiconductor substrates. Shielded by 2 km of rock overburden, the Cryogenic Underground TEst facility (CUTE) at SNOLAB provides a unique ultra-low radiation environment to probe the performance of quantum technologies with a particular interest in quantum coherence studies. In this article, we present the findings of an extensive material assaying program in preparation for the first underground operation of superconducting qubits at SNOLAB. The radioactivity levels identified by the material assays enter a thorough Monte Carlo study based on the Geant4 particle physics tracking code. From these simulations, we estimate the rates of energy deposits from radiogenic sources expected for a quantum-device assembly operated in the CUTE facility. We further characterize the spectral components of the projected background and identify the dominant particle interaction types. Finally, we outline how crystal dynamics simulations using the G4CMP solid-state physics extension for Geant4 can inform the community-wide efforts to identify effective strategies to mitigate the effects of high-energy particle impacts.
Abstract Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.
Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].
Abstract The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4 π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19−0.03+0.040.1{9}_{-0.03}^{+0.04}0.19−0.03+0.04​ 0.1 9 − 0.03 + 0.04 mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
Abstract Superconducting qubits can be sensitive to energy deposits caused by cosmic rays and ambient radioactivity. While previous studies have explored correlated effects in time and space due to cosmic ray interactions, we present the first direct comparison of a transmon qubit’s performance measured at two distinct sites: the above-ground SQMS facility (Fermilab, US) and the deep-underground Gran Sasso Laboratory (Italy). Despite the stark difference in radiation levels, we observe a similar average qubit relaxation time of approximately 80 microseconds at both locations. To investigate radiation-induced events, we employ a fast decay detection protocol, comparing the relative rates of events between the two environments. Although intrinsic noise remains the dominant source of errors in superconducting qubits, our analysis revealed a significant excess of radiation-induced events for high-coherence transmon qubits operated above-ground. Finally, using γ -ray sources with increasing activity levels, we evaluate the qubit response in a controlled low-background environment.
Abstract Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of radioactivity present in a typical laboratory environment (from muons, neutrons, and γ\gamma γ γ -rays emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly and operation of state-of-the-art superconducting qubits. We present a GEANT-4 based simulation to predict the rate of impacts and the amount of energy released in a qubit chip from each of the mentioned sources. We finally propose mitigation strategies for the operation of next-generation qubits in a radio-pure environment.
Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.