arXiv:2403.08731 · Applied Physics Letters

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Pauli Kehayias, Matthew A. Delaney, Raymond A. Haltli, Susan Clark, Melissa Revelle, Andrew M. Mounce

Published Dec 16, 2024• 4 citations
arXivHTMLPDF

Abstract

As quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

DOI
10.1063/5.0234269

Related papers

Development of microfabricated ion traps for scalable microwave quantum technology

Bjoern Lekitsch

Microfabricated ion traps are an important tool in the development of scalable quantum systems. Tremendous advancements towards an ion quantum computer were made in the past decade and most requirements for a quantum computer have been fulfilled in individual experiments. Incorporating all essential capabilities in a fully scalable system will require the further advancement of established quantum information technologies and development of new trap fabrication techniques. In my thesis I will discuss the theoretical background and experimental setup required for the operation of ion traps. Measurement of the important ion trap heating rate was performed in the setup and I will discuss the results in more detail. I will give a review of microfabrication processes used for the fabrication of traps, outlining advantages, disadvantages and issues inherent to the processes. Following the review I will present my work on a concept for a scalable ion trap quantum system based on microwave quantum gates and shuttling through X-junctions. Many of the required building blocks, including ion trap structures with current-carrying wires intended to create strong magnetic field gradients for microwave gates were investigated further. A novel fabrication process was developed to combine current-carrying wires with advanced multilayered ion trap structures. Several trap designs intended for proof of principle experiments of high fidelity microwave gates, advanced detection techniques and shuttling between electrically disconnected ion traps will be presented. Also the electrode geometry of an optimized X-junction design with strongly suppressed rf barrier height will be presented. Further, I developed several modifications for the experimental setup to extend the existing capabilities. A plasma source capable of performing in-situ cleans of the trap electrode surfaces, which has been demonstrated to dramatically reduce the heating rate in ion traps, was incorporated. I will also present a vacuum system modification designed to cool ion traps with current-carrying wires and transport the generated heat out of the vacuum system. In addition a novel low-noise, high-speed, multichannel voltage control system was developed by me. The device can be used in future experiments to precisely shuttle ions from one trapping zone to another and also to shuttle ions through ion trap junctions. Lastly I will outline the process optimization and microfabrication of my ion trap designs. A novel fabrication process which makes use of the extremely high thermal conductivity of diamond substrates and combines it with thick copper tracks embedded in the substrate was developed. Large currents will be passed through the wires creating a strong and controllable magnetic field gradient. Ion trap designs with isolated electrodes connected via buried wires can be placed on top of the current-carrying wires, allowing the most advanced electrode designs to be fabricated with current-carrying wires.

•May 18, 2015•0 citations

Generation of Nitrogen-Vacancy Centers in Diamond with Ion Implantation

Jin‐Ming Cui, Xiang-Dong Chen, Lele Fan +5 more

Nitrogen-vacancy defect color centers are created in a high purity single crystal diamond by nitrogen-ion implantation. Both optical spectrum and optically detected magnetic resonance are measured for these artificial quantum emitters. Moreover, with a suitable mask, a lattice composed of nitrogen-vacancy centers is fabricated. Rabi oscillation driven by micro-waves is carried out to show the quality of the ion implantation and potential in quantum manipulation. Along with compatible standard lithography, such an implantation technique shows high potential in future to make structures with nitrogen-vacancy centers for diamond photonics and integrated photonic quantum chip.

Chinese Physics Letters•Mar 1, 2012•22 citations

Quantum Diamond Microscopy for Non-Destructive Failure Analysis of an Integrated Fan-Out Package-on-Package iPhone Chip

Bartu Bisgin, Marwa Garsi, Andreas Welscher +2 more

The increasing complexity of advanced semiconductor packages, driven by chiplet architectures and 2.5D/3D integration, challenges conventional failure localization methods such as lock-in thermography (LIT) and complicates current Failure Analysis (FA) workflows. Dense redistribution layers and buried interconnects limit the ability of established techniques to understand failure mechanisms non-destructively. In this work, we validate quantum diamond microscopy (QDM) based on nitrogen-vacancy (NV) centers in diamond as a non-destructive localization method through magnetic current path imaging at the package level. Using commercial Integrated Fan-Out Package-on- Package (InFO-PoP) devices from iPhones, we showcase a complete FA workflow that includes QDM to localize a short-type failure at an Integrated Passive Device (IPD) at the package backside. We showcase that the QDM results provide invaluable information on top of conventional techniques and can significantly enhance root-cause identification in package-level FA workflows. This work demonstrates the potential of QDM for broader integration into semiconductor chip and package analysis workflows.

quant-pharXiv:2512.07619•Dec 9, 2025

New Quantum Sensing Modalities of Nitrogen-Vacancy Centers

Qiu, Ziwei

The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.

•Jan 1, 2022•0 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications

Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3 more

Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.

quant-pharXiv:2609.04733•Sep 7, 2026
As quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.
Microfabricated ion traps are an important tool in the development of scalable quantum systems. Tremendous advancements towards an ion quantum computer were made in the past decade and most requirements for a quantum computer have been fulfilled in individual experiments. Incorporating all essential capabilities in a fully scalable system will require the further advancement of established quantum information technologies and development of new trap fabrication techniques. In my thesis I will discuss the theoretical background and experimental setup required for the operation of ion traps. Measurement of the important ion trap heating rate was performed in the setup and I will discuss the results in more detail. I will give a review of microfabrication processes used for the fabrication of traps, outlining advantages, disadvantages and issues inherent to the processes. Following the review I will present my work on a concept for a scalable ion trap quantum system based on microwave quantum gates and shuttling through X-junctions. Many of the required building blocks, including ion trap structures with current-carrying wires intended to create strong magnetic field gradients for microwave gates were investigated further. A novel fabrication process was developed to combine current-carrying wires with advanced multilayered ion trap structures. Several trap designs intended for proof of principle experiments of high fidelity microwave gates, advanced detection techniques and shuttling between electrically disconnected ion traps will be presented. Also the electrode geometry of an optimized X-junction design with strongly suppressed rf barrier height will be presented. Further, I developed several modifications for the experimental setup to extend the existing capabilities. A plasma source capable of performing in-situ cleans of the trap electrode surfaces, which has been demonstrated to dramatically reduce the heating rate in ion traps, was incorporated. I will also present a vacuum system modification designed to cool ion traps with current-carrying wires and transport the generated heat out of the vacuum system. In addition a novel low-noise, high-speed, multichannel voltage control system was developed by me. The device can be used in future experiments to precisely shuttle ions from one trapping zone to another and also to shuttle ions through ion trap junctions. Lastly I will outline the process optimization and microfabrication of my ion trap designs. A novel fabrication process which makes use of the extremely high thermal conductivity of diamond substrates and combines it with thick copper tracks embedded in the substrate was developed. Large currents will be passed through the wires creating a strong and controllable magnetic field gradient. Ion trap designs with isolated electrodes connected via buried wires can be placed on top of the current-carrying wires, allowing the most advanced electrode designs to be fabricated with current-carrying wires.
Nitrogen-vacancy defect color centers are created in a high purity single crystal diamond by nitrogen-ion implantation. Both optical spectrum and optically detected magnetic resonance are measured for these artificial quantum emitters. Moreover, with a suitable mask, a lattice composed of nitrogen-vacancy centers is fabricated. Rabi oscillation driven by micro-waves is carried out to show the quality of the ion implantation and potential in quantum manipulation. Along with compatible standard lithography, such an implantation technique shows high potential in future to make structures with nitrogen-vacancy centers for diamond photonics and integrated photonic quantum chip.
The increasing complexity of advanced semiconductor packages, driven by chiplet architectures and 2.5D/3D integration, challenges conventional failure localization methods such as lock-in thermography (LIT) and complicates current Failure Analysis (FA) workflows. Dense redistribution layers and buried interconnects limit the ability of established techniques to understand failure mechanisms non-destructively. In this work, we validate quantum diamond microscopy (QDM) based on nitrogen-vacancy (NV) centers in diamond as a non-destructive localization method through magnetic current path imaging at the package level. Using commercial Integrated Fan-Out Package-on- Package (InFO-PoP) devices from iPhones, we showcase a complete FA workflow that includes QDM to localize a short-type failure at an Integrated Passive Device (IPD) at the package backside. We showcase that the QDM results provide invaluable information on top of conventional techniques and can significantly enhance root-cause identification in package-level FA workflows. This work demonstrates the potential of QDM for broader integration into semiconductor chip and package analysis workflows.
The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.