arXiv:2312.12256 · Physical Review Applied

Cavity-enhanced detection of spin polarization in a microfabricated atomic vapor cell

María Hernández Ruiz, Yintao Ma, Hana Medhat, Chiara Mazzinghi, Vito Giovanni Lucivero, Morgan W. Mitchell

Published Jun 6, 2024• 7 citations
arXivHTMLPDF

Abstract

We demonstrate continuous Pound-Drever-Hall (PDH) nondestructive monitoring of the electron spin polarization of an atomic vapor in a microfabricated vapor cell within an optical resonator. The two-chamber silicon and glass cell contains ${}^{87}$Rb and 1.3 amg of ${\mathrm{N}}_{2}$ buffer gas, and is placed within a planar optical resonator formed by two mirrors with dichroic dielectric coatings to resonantly enhance the coupling to phase-modulated probe light near the ${D}_{2}$ line at 780 nm. We describe the theory of signal generation in this system, including the spin-dependent complex refractive index, cavity optical transfer functions, and PDH signal response to spin polarization. We observe cavity transmission and PDH signals across approximately 200 GHz of detuning around the atomic resonance line. By resonant optical pumping on the 795-nm ${D}_{1}$ line, we observe spin-dependent cavity line shifts, in good agreement with theory. We use the saturation of the line shift versus optical pumping power to calibrate the number density and efficiency of the optical pumping. In the unresolved sideband regime, we observe quantum noise limited PDH readout of the spin polarization density, with a flat noise floor of 9\ifmmode\times\else\texttimes\fi{}${10}^{9}\phantom{\rule{0.1em}{0ex}}{\text{spins cm}}^{\ensuremath{-}3}\phantom{\rule{0.2em}{0ex}}{\text{Hz}}^{\ensuremath{-}1/2}$ for frequencies above 700 Hz. We note possible extensions of the technique.

DOI
10.1103/physrevapplied.21.064014

Related papers

Sensitivity Scaling and Limits of Cavity Enhancement in Miniaturized Optically Pumped Magnetometers

Christopher H. Kiehl, María Hernández Ruiz, Cristina Sastre Jachimska +1 more

The sensitivity of miniaturized optically pumped magnetometers (OPMs) is limited by weak atom-light coupling, which an optical cavity can enhance. In this work, we model the photon-shot-noise-limited sensitivity of cavity-enhanced OPMs in the regime of strongly collisionally broadened optical transitions, characteristic of buffer-gas-filled miniaturized vapor cells. The cavity enhancement is benchmarked against a single-pass free-induction-decay OPM employing Faraday-rotation readout, with the probe power and detuning jointly optimized using the Cramér-Rao lower bound as a figure of merit. For a Fabry-Pérot cavity, we compare side-of-fringe, homodyne, Pound-Drever-Hall, and Faraday-rotation readout. All four yield an optimal sensitivity enhancement scaling as $α\sqrt{2\mathcal{F}/π}$, where $\mathcal{F}$ is the cavity finesse and $0.5\leq α\leq 1$ is a readout-dependent prefactor. The enhancement is maximized at critical coupling, and we quantify its degradation away from this point. We further show that, despite spin-dependent absorption associated with the ensemble's vector polarizability, near-critical coupling can be maintained throughout spin precession at arbitrary finesse by exceeding a derived probe-power threshold and increasing the atomic detuning with finesse. We also establish a limit to the maximum cavity enhancement set by vector light-shift noise.

physics.atom-phCross-listedarXiv:2608.16670•Aug 18, 2026•0 citations

Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

Vinu Venkatraman, Songbai Kang, C. Affolderbach +2 more

Miniature (<few cm3) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm3 as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm3 volume) test setup based on the Mz magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.

Applied Physics Letters•Feb 3, 2014•15 citations

Cavity-enhanced absorption sensing based on Pound-Drever-Hall sideband locking

Fernanda Cristina Rodrigues Machado

We present a cavity-enhanced optical absorption measurement technique based on high-bandwidth Pound-Drever-Hall (PDH) sideband locking, which naturally provides a real-time, resonant amplitude quadrature readout that can be mapped onto the cavity’s internal loss rate. Cavity-enhancement is widely used in the detection of small signals -- an optical cavity traps photons between two highly reflective mirrors, thereby enhancing the effective path length through the absorber [Romanini et al., 2014]. Most of the available techniques, however, probe transmission signals and/or do not provide the stability required for the detection of fast signals.To ensure optimal enhancement of absorption sensitivity, probe light must be locked on resonance with the cavity. PDH locking relies on phase modulation of a laser beam, creating two sidebands on the original carrier frequency [Black, 2001]. Upon reflection from a cavity, this modulated light produces a heterodyne signal (beat note) that can be detected and demodulated. We use the phase quadrature of the beat note to lock the cavity on resonance with one of the sidebands, achieving a locking bandwidth in the MHz range that keeps cavity and probe light resonant for hours [Reinhardt et al., 2017]. Simultaneously, we monitor the amplitude quadrature, which provides a continuous, real-time, heterodyne-amplified readout of the cavity’s internal absorption. Our PDH sideband cavity-enhanced absorption readout technique (SideCAR) ensures high sensitivity without reaching saturation limits in the intracavity medium by keeping a relatively low intracavity power, since only one of the sidebands is allowed to enter the cavity, but the signal is boosted above the detector noise by heterodyne detection (using the carrier as a local oscillator).This thesis presents the theoretical formulation of the sensing technique together with the expressions for the sensitivity limit (ultimately given by the laser quantum noise), and the experimental results from a test cavity setup. Probing a proof-of-concept 5-cm-long Fabry-Perot cavity with a coupled power of 160 uW, we measure an absorption sensitivity of 7*10^(-11) cm^(-1)/sqrt(Hz) at 100 kHz (roughly the cavity bandwidth), a factor of 11 from the shot-noise limit. This technique allows the detection of small, transient signals against absorptive backgrounds with sensitivity close to the shot noise limit using a reflection-based measurement in a fairly simple setup, opening the possibility of developing new microscopic single-port real-world sensors for transients, for example using micron-scale optical fiber cavities

•Jan 1, 2022•0 citations

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

Optics Express•Dec 9, 2010•183 citations

Pound-Drever-Hall locking of four-mirror optical cavity for cold atom interferometry

shaojun gao, guodong xin, qufei wang +2 more

Atom interferometers, as precision gravity sensors, encounter inherent miniaturization challenges due to constraints like interference time and laser pulse intensity. Optical cavities address these limitations through wavefront purification, spatial mode filtering, and resonance-enhanced amplification, significantly enhancing interferometer stability and performance for compact quantum sensing applications. This study develops a fiber-integrated four-mirror cavity locking system based on the Pound-Drever-Hall (PDH) technique combined with modulation transfer spectroscopy (MTS), designed for cavityenhanced Raman resonance control in atom interferometry. The system utilizes a fiber-based electro-optic modulator (EOM) for red-detuned frequency shifting, with MTS stabilization applied to lock the cavity to the +1st-order sideband while maintaining the carrier as the locking beam. A fiber-optic circulator architecture in the PDH feedback loop eliminates environmental disturbances (stray light and vibrations) on dispersion-based error signals. Experimental implementation demonstrates continuous cavity locking for over 2 hours with transmitted power fluctuations below 2%. Validation using pulsed Raman beams (400μs duration) confirms the scheme's compatibility with cavity-enhanced atom interferometry, establishing a methodological framework for multi-beam quantum interference experiments in optical cavity.

International Conference on Laser, Optics and Optoelectronic Technology (LOPET)•Aug 20, 2025•0 citations

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

APS•Mar 1, 2010•0 citations
We demonstrate continuous Pound-Drever-Hall (PDH) nondestructive monitoring of the electron spin polarization of an atomic vapor in a microfabricated vapor cell within an optical resonator. The two-chamber silicon and glass cell contains 87{}^{87}87Rb and 1.3 amg of N2{\mathrm{N}}_{2}N2​ buffer gas, and is placed within a planar optical resonator formed by two mirrors with dichroic dielectric coatings to resonantly enhance the coupling to phase-modulated probe light near the D2{D}_{2}D2​ line at 780 nm. We describe the theory of signal generation in this system, including the spin-dependent complex refractive index, cavity optical transfer functions, and PDH signal response to spin polarization. We observe cavity transmission and PDH signals across approximately 200 GHz of detuning around the atomic resonance line. By resonant optical pumping on the 795-nm D1{D}_{1}D1​ line, we observe spin-dependent cavity line shifts, in good agreement with theory. We use the saturation of the line shift versus optical pumping power to calibrate the number density and efficiency of the optical pumping. In the unresolved sideband regime, we observe quantum noise limited PDH readout of the spin polarization density, with a flat noise floor of 9\ifmmode\times\else\texttimes\fi{}109spins cm\ensuremath−3Hz\ensuremath−1/2{10}^{9}\phantom{\rule{0.1em}{0ex}}{\text{spins cm}}^{\ensuremath{-}3}\phantom{\rule{0.2em}{0ex}}{\text{Hz}}^{\ensuremath{-}1/2}109spins cm\ensuremath−3Hz\ensuremath−1/2 for frequencies above 700 Hz. We note possible extensions of the technique.
The sensitivity of miniaturized optically pumped magnetometers (OPMs) is limited by weak atom-light coupling, which an optical cavity can enhance. In this work, we model the photon-shot-noise-limited sensitivity of cavity-enhanced OPMs in the regime of strongly collisionally broadened optical transitions, characteristic of buffer-gas-filled miniaturized vapor cells. The cavity enhancement is benchmarked against a single-pass free-induction-decay OPM employing Faraday-rotation readout, with the probe power and detuning jointly optimized using the Cramér-Rao lower bound as a figure of merit. For a Fabry-Pérot cavity, we compare side-of-fringe, homodyne, Pound-Drever-Hall, and Faraday-rotation readout. All four yield an optimal sensitivity enhancement scaling as α2F/πα\sqrt{2\mathcal{F}/π}α2F/π​, where F\mathcal{F}F is the cavity finesse and 0.5≤α≤10.5\leq α\leq 10.5≤α≤1 is a readout-dependent prefactor. The enhancement is maximized at critical coupling, and we quantify its degradation away from this point. We further show that, despite spin-dependent absorption associated with the ensemble's vector polarizability, near-critical coupling can be maintained throughout spin precession at arbitrary finesse by exceeding a derived probe-power threshold and increasing the atomic detuning with finesse. We also establish a limit to the maximum cavity enhancement set by vector light-shift noise.
Miniature (<few cm3) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm3 as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm3 volume) test setup based on the Mz magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.
We present a cavity-enhanced optical absorption measurement technique based on high-bandwidth Pound-Drever-Hall (PDH) sideband locking, which naturally provides a real-time, resonant amplitude quadrature readout that can be mapped onto the cavity’s internal loss rate. Cavity-enhancement is widely used in the detection of small signals -- an optical cavity traps photons between two highly reflective mirrors, thereby enhancing the effective path length through the absorber [Romanini et al., 2014]. Most of the available techniques, however, probe transmission signals and/or do not provide the stability required for the detection of fast signals.To ensure optimal enhancement of absorption sensitivity, probe light must be locked on resonance with the cavity. PDH locking relies on phase modulation of a laser beam, creating two sidebands on the original carrier frequency [Black, 2001]. Upon reflection from a cavity, this modulated light produces a heterodyne signal (beat note) that can be detected and demodulated. We use the phase quadrature of the beat note to lock the cavity on resonance with one of the sidebands, achieving a locking bandwidth in the MHz range that keeps cavity and probe light resonant for hours [Reinhardt et al., 2017]. Simultaneously, we monitor the amplitude quadrature, which provides a continuous, real-time, heterodyne-amplified readout of the cavity’s internal absorption. Our PDH sideband cavity-enhanced absorption readout technique (SideCAR) ensures high sensitivity without reaching saturation limits in the intracavity medium by keeping a relatively low intracavity power, since only one of the sidebands is allowed to enter the cavity, but the signal is boosted above the detector noise by heterodyne detection (using the carrier as a local oscillator).This thesis presents the theoretical formulation of the sensing technique together with the expressions for the sensitivity limit (ultimately given by the laser quantum noise), and the experimental results from a test cavity setup. Probing a proof-of-concept 5-cm-long Fabry-Perot cavity with a coupled power of 160 uW, we measure an absorption sensitivity of 7*10^(-11) cm^(-1)/sqrt(Hz) at 100 kHz (roughly the cavity bandwidth), a factor of 11 from the shot-noise limit. This technique allows the detection of small, transient signals against absorptive backgrounds with sensitivity close to the shot noise limit using a reflection-based measurement in a fairly simple setup, opening the possibility of developing new microscopic single-port real-world sensors for transients, for example using micron-scale optical fiber cavities
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.
Atom interferometers, as precision gravity sensors, encounter inherent miniaturization challenges due to constraints like interference time and laser pulse intensity. Optical cavities address these limitations through wavefront purification, spatial mode filtering, and resonance-enhanced amplification, significantly enhancing interferometer stability and performance for compact quantum sensing applications. This study develops a fiber-integrated four-mirror cavity locking system based on the Pound-Drever-Hall (PDH) technique combined with modulation transfer spectroscopy (MTS), designed for cavityenhanced Raman resonance control in atom interferometry. The system utilizes a fiber-based electro-optic modulator (EOM) for red-detuned frequency shifting, with MTS stabilization applied to lock the cavity to the +1st-order sideband while maintaining the carrier as the locking beam. A fiber-optic circulator architecture in the PDH feedback loop eliminates environmental disturbances (stray light and vibrations) on dispersion-based error signals. Experimental implementation demonstrates continuous cavity locking for over 2 hours with transmitted power fluctuations below 2%. Validation using pulsed Raman beams (400μs duration) confirms the scheme's compatibility with cavity-enhanced atom interferometry, establishing a methodological framework for multi-beam quantum interference experiments in optical cavity.
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.