The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics, and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

DOI
10.48550/arxiv.2311.05714

Related papers

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

Jonah Glick, Z. Chen, Tejas Deshpande +2 more

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

AVS Quantum Science•Jan 10, 2024•13 citations

Coriolis compensation via gravity in a matter-wave interferometer

Yaakov Y. Fein, Filip Kiałka, Philipp Geyer +2 more

Abstract Matter-wave interferometry offers insights into fundamental physics and provides a precise tool for sensing. Improving the sensitivity of such experiments requires increasing the time particles spend in the interferometer, which can lead to dephasing in the presence of velocity-dependent phase shifts such as those produced by the Earth’s rotation. Here we present a technique to passively compensate for the Coriolis effect using gravity, without the need for any moving components. We demonstrate the technique with fullerenes in a long-baseline molecule interferometer by measuring the gravitational and Coriolis phase shifts and obtaining the maximum visibility one would expect in the absence of the Coriolis effect.

New Journal of Physics•Feb 7, 2020•11 citations

Influence of the Coriolis Force in Atom Interferometry

Shau-Yu Lan, Pei-Chen Kuan, Brian Estey +2 more

In a light-pulse atom interferometer, we use a tip-tilt mirror to remove the influence of the Coriolis force from Earth's rotation and to characterize configuration space wave packets. For interferometers with a large momentum transfer and large pulse separation time, we improve the contrast by up to 350% and suppress systematic effects. We also reach what is to our knowledge the largest space-time area enclosed in any atom interferometer to date. We discuss implications for future high-performance instruments.

arXiv:1110.6910•Physical Review Letters•Feb 27, 2012•173 citations

An atom interferometer for measuring horizontal accelerations

Jimmy Stammers

Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.

•Nov 1, 2018•6 citations

Coriolis effect due to laser beam tilting in an atom interferometer

Li Li, Lele Chen, Qin Luo +3 more

The Coriolis effect can introduce significant systematic errors in atom interferometers. This study examines the coupling effect between the Coriolis effect and the Raman beams–orientation in a fountain atomic gravimeter. Theoretical analysis indicates that the Coriolis effect is correlated with the orientation of the Raman beams, and tilt modulation experiments were conducted to substantiate this correlation. Furthermore, by aligning the orientations of the atomic fountain, the vacuum chamber, and the Raman mirror, we achieved simultaneous suppression of both the Coriolis effect and the tilt effect to sub- μ Gal levels in a high-precision atomic gravimeter. This work offers guidance on assessing systematic errors in high-precision atomic gravimeters.

Optics Express•Dec 17, 2024•3 citations

Laser system for the 100-meter-tall MAGIS-100 atom interferometer

Kenneth DeRose

MAGIS-100 is a 100-meter atom interferometer currently being built at Fermilab and will be the worlds largest atom fountain. It will leverage modern atom optics techniques to search for dark matter, perform quantum atomic experiments, and detect gravitational waves at frequencies inaccessible to LIGO and LISA. Generation and precise control of meter-separated quantum atomic superpositions within the interferometer requires an agile laser system able to rapidly shift the optical frequency up to a rate of 100 GHz/s while maintaining a phase lock to our static frequency comb. To meet the power requirement of the experiment, the two interferometry lasers are coherently locked and must be robust to rapid frequency shifts. The interferometry laser's spatial mode is cleaned through fiber coupling and long free space propagation in vacuum with frequency noise introduced by the fiber suppressed by a PID lock. In addition to the scientific and technical hurdles in this experiment, there are complex laser safety issues. There are a total of twenty-four lasers and seven wavelengths ranging from 50mW to 100W, all within the same LCA.

International Laser Safety Conference (ILSC)•Mar 1, 2023•0 citations
The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics, and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.
The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.
Abstract Matter-wave interferometry offers insights into fundamental physics and provides a precise tool for sensing. Improving the sensitivity of such experiments requires increasing the time particles spend in the interferometer, which can lead to dephasing in the presence of velocity-dependent phase shifts such as those produced by the Earth’s rotation. Here we present a technique to passively compensate for the Coriolis effect using gravity, without the need for any moving components. We demonstrate the technique with fullerenes in a long-baseline molecule interferometer by measuring the gravitational and Coriolis phase shifts and obtaining the maximum visibility one would expect in the absence of the Coriolis effect.
In a light-pulse atom interferometer, we use a tip-tilt mirror to remove the influence of the Coriolis force from Earth's rotation and to characterize configuration space wave packets. For interferometers with a large momentum transfer and large pulse separation time, we improve the contrast by up to 350% and suppress systematic effects. We also reach what is to our knowledge the largest space-time area enclosed in any atom interferometer to date. We discuss implications for future high-performance instruments.
Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.
The Coriolis effect can introduce significant systematic errors in atom interferometers. This study examines the coupling effect between the Coriolis effect and the Raman beams–orientation in a fountain atomic gravimeter. Theoretical analysis indicates that the Coriolis effect is correlated with the orientation of the Raman beams, and tilt modulation experiments were conducted to substantiate this correlation. Furthermore, by aligning the orientations of the atomic fountain, the vacuum chamber, and the Raman mirror, we achieved simultaneous suppression of both the Coriolis effect and the tilt effect to sub- μ Gal levels in a high-precision atomic gravimeter. This work offers guidance on assessing systematic errors in high-precision atomic gravimeters.
MAGIS-100 is a 100-meter atom interferometer currently being built at Fermilab and will be the worlds largest atom fountain. It will leverage modern atom optics techniques to search for dark matter, perform quantum atomic experiments, and detect gravitational waves at frequencies inaccessible to LIGO and LISA. Generation and precise control of meter-separated quantum atomic superpositions within the interferometer requires an agile laser system able to rapidly shift the optical frequency up to a rate of 100 GHz/s while maintaining a phase lock to our static frequency comb. To meet the power requirement of the experiment, the two interferometry lasers are coherently locked and must be robust to rapid frequency shifts. The interferometry laser's spatial mode is cleaned through fiber coupling and long free space propagation in vacuum with frequency noise introduced by the fiber suppressed by a PID lock. In addition to the scientific and technical hurdles in this experiment, there are complex laser safety issues. There are a total of twenty-four lasers and seven wavelengths ranging from 50mW to 100W, all within the same LCA.