Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2308.11481 · AVS Quantum Science

Guided-wave Sagnac atom interferometer with large area and multiple orbits

Marybeth Beydler, Edward Moan, Zhe Luo, Z. Chu, Charles A. Sackett

Published Jan 9, 2024• 15 citations
arXivHTMLPDF

Abstract

We describe a matter-wave Sagnac interferometer using Bose condensed atoms confined in a time-orbiting potential trap. Compared to our previous implementation [Moan et al., Phys. Rev. Lett. 124, 120403 (2020)], our new apparatus provides better thermal stability, improved optical access, and reduced trap anharmonicity. The trapping field can be adjusted to compensate for small tilts of the apparatus in gravity. These features enable operation with an effective Sagnac area of 4 mm2 per orbit, and we observe interference with 25% visibility after two orbits at a total interrogation time of 0.6 s. Long-term measurements indicate a phase stability of 0.2 rad or better.

DOI
10.1116/5.0173769

Related papers

A large-area Sagnac interferometer using atoms in a time-orbiting potential

Charles A. Sackett, Edward Moan, Zhe Luo

We describe an implementation of a Sagnac interferometer using a Bose-Einstein condensate confined in a harmonic time-orbiting potential trap. Atoms are manipulated using Bragg laser beams to produce two reciprocal interferometers, providing common-mode rejection of accelerations, trap fluctuations, and most other effects. The Sagnac rotation phase is differential. The orbit of the atoms is nearly circular, with an effective Sagnac area of about 0.5 mm2.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•2 citations

Multiloop and multiaxis atomtronic Sagnac interferometry

Saurabh Pandey, Ceren Uzun, Katarzyna Anna Krzyzanowska +1 more

We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.

arXiv:2504.20345•Physical Review Research•Jan 20, 2026•2 citations

Multi-pass guided atomic Sagnac interferometer for high-performance rotation sensing

S. Moukouri, Yonathan Japha, Mark Keil +4 more

Matter-wave interferometry with atoms propagating in a guiding potential is expected to provide compact, scalable and precise inertial sensing. However, a rotation sensing device based on the Sagnac effect with atoms guided in a ring has not yet been implemented despite continuous efforts during the last two decades. Here we discuss some intrinsic effects that limit the coherence in such a device and propose a scheme that overcomes these limitations and enables a multi-pass guiding Sagnac interferometer with a Bose-Einstein condensate (BEC) on a chip in a ring potential. We analyze crucial dephasing effects: potential roughness, phase diffusion due to atom-atom interactions and number uncertainty, and phase fluctuations. Owing to the recent progress in achieving high momentum beam splitting, creating smooth guides, and manipulating the matter-wavepacket propagation, guided interferometry can be implemented within the coherence time allowed by phase diffusion. Despite the lower particle flux in a guided Sagnac ring and the miniaturization of the interferometer, the estimated sensitivity, for reasonable and practical realizations of an atom chip-based gyroscope, is comparable to that of free-space interferometers, reaching 45 nrads^{-1}Hz^{-1/2}. A significant improvement over state-of-the-art free-space gyrocope sensitivities can be envisioned by using thermal atoms instead of a BEC, whereby the interferometer can be operated in a continuous fashion with the coherence limited by the scattering rate of the atoms with the background gas. Taking into account the sensitivity times length of the interferometer as the figure of merit which takes into account compactness, our configuration is expected to deliver a potential improvement of 2-4 orders of magnitude over state-of-the-art free-space gyroscopes for a BEC, and 4-6 orders of magnitude for thermal atoms.

arXiv:2107.03446•Jul 7, 2021•5 citations

Semiclassical Phase Analysis for a Trapped-Atom Sagnac Interferometer

Zhe Luo, Edward Moan, Charles A. Sackett

A Sagnac atom interferometer can be constructed using a Bose–Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits, with two counterpropagating interferometers allowing many sources of common-mode noise to be excluded. In a perfectly symmetric and harmonic potential, the interferometer output would depend only on the rotation rate of the apparatus. However, deviations from the ideal case can lead to spurious phase shifts. These phase shifts have been theoretically analyzed for anharmonic perturbations up to quartic in the confining potential, as well as angular deviations of the laser beams, timing deviations of the laser pulses, and motional excitations of the initial condensate. Analytical and numerical results show the leading effects of the perturbations to be second order. The scaling of the phase shifts with the number of orbits and the trap axial frequency ratio are determined. The results indicate that sensitive parameters should be controlled at the 10−5 level to accommodate a rotation sensing accuracy of 10−9 rad/s. The leading-order perturbations are suppressed in the case of perfect cylindrical symmetry, even in the presence of anharmonicity and other errors. An experimental measurement of one of the perturbation terms is presented.

arXiv:2103.13996•Atoms•Mar 27, 2021•2 citations

Multi-loop atomic Sagnac interferometry

Christian Schubert, Sven Abend, Matthias Gersemann +4 more

The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as [Formula: see text] rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.

arXiv:2102.00991•Scientific Reports•Aug 9, 2021•35 citations

Controlling the dynamical scale factor in a trapped atom Sagnac interferometer

Yijia Zhou, Igor Lesanovsky, T. Fernholz +1 more

Sagnac interferometers with massive particles promise unique advantages in achieving high-precision measurements of rotation rates over their optical counterparts. Recent proposals and experiments are exploring nonballistic Sagnac interferometers where trapped atoms are transported along a closed path. This is achieved by using superpositions of internal quantum states and their control with state-dependent potentials. We address emergent questions regarding the dynamical behavior of Bose-Einstein condensates in such an interferometer and its impact on rotation sensitivity. We investigate complex dependencies on atomic interactions as well as trap geometries, rotation rates, and speed of operation. We find that temporal transport profiles obtained from a simple optimization strategy for noninteracting particles remain surprisingly robust also in the presence of interactions over a large range of realistic parameters. High sensitivities can be achieved for short interrogation times far from the adiabatic regime. This highlights a route to building fast and robust guided-ring Sagnac interferometers with fully trapped atoms.

arXiv:1811.11107•Physical Review A•Jan 29, 2020•3 citations
We describe a matter-wave Sagnac interferometer using Bose condensed atoms confined in a time-orbiting potential trap. Compared to our previous implementation [Moan et al., Phys. Rev. Lett. 124, 120403 (2020)], our new apparatus provides better thermal stability, improved optical access, and reduced trap anharmonicity. The trapping field can be adjusted to compensate for small tilts of the apparatus in gravity. These features enable operation with an effective Sagnac area of 4 mm2 per orbit, and we observe interference with 25% visibility after two orbits at a total interrogation time of 0.6 s. Long-term measurements indicate a phase stability of 0.2 rad or better.
We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.
Matter-wave interferometry with atoms propagating in a guiding potential is expected to provide compact, scalable and precise inertial sensing. However, a rotation sensing device based on the Sagnac effect with atoms guided in a ring has not yet been implemented despite continuous efforts during the last two decades. Here we discuss some intrinsic effects that limit the coherence in such a device and propose a scheme that overcomes these limitations and enables a multi-pass guiding Sagnac interferometer with a Bose-Einstein condensate (BEC) on a chip in a ring potential. We analyze crucial dephasing effects: potential roughness, phase diffusion due to atom-atom interactions and number uncertainty, and phase fluctuations. Owing to the recent progress in achieving high momentum beam splitting, creating smooth guides, and manipulating the matter-wavepacket propagation, guided interferometry can be implemented within the coherence time allowed by phase diffusion. Despite the lower particle flux in a guided Sagnac ring and the miniaturization of the interferometer, the estimated sensitivity, for reasonable and practical realizations of an atom chip-based gyroscope, is comparable to that of free-space interferometers, reaching 45 nrads^{-1}Hz^{-1/2}. A significant improvement over state-of-the-art free-space gyrocope sensitivities can be envisioned by using thermal atoms instead of a BEC, whereby the interferometer can be operated in a continuous fashion with the coherence limited by the scattering rate of the atoms with the background gas. Taking into account the sensitivity times length of the interferometer as the figure of merit which takes into account compactness, our configuration is expected to deliver a potential improvement of 2-4 orders of magnitude over state-of-the-art free-space gyroscopes for a BEC, and 4-6 orders of magnitude for thermal atoms.
A Sagnac atom interferometer can be constructed using a Bose–Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits, with two counterpropagating interferometers allowing many sources of common-mode noise to be excluded. In a perfectly symmetric and harmonic potential, the interferometer output would depend only on the rotation rate of the apparatus. However, deviations from the ideal case can lead to spurious phase shifts. These phase shifts have been theoretically analyzed for anharmonic perturbations up to quartic in the confining potential, as well as angular deviations of the laser beams, timing deviations of the laser pulses, and motional excitations of the initial condensate. Analytical and numerical results show the leading effects of the perturbations to be second order. The scaling of the phase shifts with the number of orbits and the trap axial frequency ratio are determined. The results indicate that sensitive parameters should be controlled at the 10−5 level to accommodate a rotation sensing accuracy of 10−9 rad/s. The leading-order perturbations are suppressed in the case of perfect cylindrical symmetry, even in the presence of anharmonicity and other errors. An experimental measurement of one of the perturbation terms is presented.
The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as [Formula: see text] rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.
Sagnac interferometers with massive particles promise unique advantages in achieving high-precision measurements of rotation rates over their optical counterparts. Recent proposals and experiments are exploring nonballistic Sagnac interferometers where trapped atoms are transported along a closed path. This is achieved by using superpositions of internal quantum states and their control with state-dependent potentials. We address emergent questions regarding the dynamical behavior of Bose-Einstein condensates in such an interferometer and its impact on rotation sensitivity. We investigate complex dependencies on atomic interactions as well as trap geometries, rotation rates, and speed of operation. We find that temporal transport profiles obtained from a simple optimization strategy for noninteracting particles remain surprisingly robust also in the presence of interactions over a large range of realistic parameters. High sensitivities can be achieved for short interrogation times far from the adiabatic regime. This highlights a route to building fast and robust guided-ring Sagnac interferometers with fully trapped atoms.