Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2102.00991 · Scientific Reports

Multi-loop atomic Sagnac interferometry

Christian Schubert, Sven Abend, Matthias Gersemann, Martina Gebbe, Dennis Schlippert, Peter Berg, Ernst Maria Rasel

Published Aug 9, 2021• 35 citations
arXivHTMLPDF

Abstract

The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as [Formula: see text] rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.

DOI
10.1038/s41598-021-95334-7

Related papers

Scalable Multi-Loop Cold Atom Rotation Sensor

Rühmann, Sandra, Ahlers, Holger, Deppner, Christian +2 more

Matter-wave interferometry with cold atoms offers a competitive tool for absolute measurements of acceleration and rotation. The sensitivity of atom-interferometric gyroscopes depends on the area enclosed by the interferometer. In this contribution, we present a concept for a rotation sensor, utilizing a multi-loop interferometer geometry to achieve a scalable area while maintaining a compact setup. It enables rotation measurements of a single axis on ground and can be extended to measure rotations along all three spatial axes in microgravity, for potential applications in space missions, Earth observation, and navigation systems.

•Mar 1, 2025•0 citations

Composite-Light-Pulse Technique for High-Precision Atom Interferometry

Peter Berg, Sven Abend, Gunnar Tackmann +6 more

We realize beam splitters and mirrors for atom waves by employing a sequence of light pulses rather than individual ones. In this way we can tailor atom interferometers with improved sensitivity and accuracy. We demonstrate our method of composite pulses by creating a symmetric matter-wave interferometer which combines the advantages of conventional Bragg- and Raman-type concepts. This feature leads to an interferometer with a high immunity to technical noise allowing us to devise a large-area Sagnac gyroscope yielding a phase shift of 6.5 rad due to the Earth's rotation. With this device we achieve a rotation rate precision of 120 nrad s(-1) Hz(-1/2) and determine the Earth's rotation rate with a relative uncertainty of 1.2%.

Physical Review Letters•Feb 9, 2015•195 citations

Multiloop and multiaxis atomtronic Sagnac interferometry

Saurabh Pandey, Ceren Uzun, Katarzyna Anna Krzyzanowska +1 more

We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.

arXiv:2504.20345•Physical Review Research•Jan 20, 2026•2 citations

The Sagnac effect: 20 years of development in matter-wave interferometry

B. Barrett, R. Geiger, Indranil Dutta +5 more

Since the first atom interferometry experiments in 1991, measurements of rotation through the Sagnac effect in open-area atom interferometers have been investigated. These studies have demonstrated very high sensitivity that can compete with state-of-the-art optical Sagnac interferometers. Since the early 2000s, these developments have been motivated by possible applications in inertial guidance and geophysics. Most matter-wave interferometers that have been investigated since then are based on two-photon Raman transitions for the manipulation of atomic wave packets. Results from the two most studied configurations, a space-domain interferometer with atomic beams and a time-domain interferometer with cold atoms, are presented and compared. Finally, the latest generation of cold atom interferometers and their preliminary results are presented.

arXiv:1412.0711•Comptes Rendus Physique•Nov 12, 2014•142 citations

Rotation sensing with a dual atom-interferometer Sagnac gyroscope

T. L. Gustavson, Arnaud Landragin, Mark A. Kasevich

We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.

Classical and Quantum Gravity•Jun 8, 2000•474 citations

Precision tests of the Sagnac effect with a two-axis atomic gyroscope

Leonid A. Sidorenkov, Romain Gauthier, Mohamed Guessoum +3 more

The Sagnac effect, manifest in the phase shift of a rotating interferometer proportional to its physical area and to the rotation rate of the frame, plays a crucial role in modern physics being generalized to any kind of interferometer. However, as compared to light, the accurate experimental validation of the Sagnac effect for matter-waves remains challenging. We report the accurate measurement of the Sagnac phase shift, induced by the Earth’s rotation, using a large-area cold atom interferometer. We probe the atomic Sagnac phase shift along the two orthogonal horizontal axes in various orientation of the sensor with respect to geographic north and obtain an agreement with the theoretical prediction at the 20 ppm level, improving by twenty five-fold over the previous achievements for matter waves. Our results underline the universality of the Sagnac effect and open new horizons for testing other fundamental theories, as well as for a number of technological applications in seismology, geodesy and inertial navigation systems.

Quantum Sensing and Nano Electronics and Photonics•Mar 8, 2024•0 citations
The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as [Formula: see text] rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.
Matter-wave interferometry with cold atoms offers a competitive tool for absolute measurements of acceleration and rotation. The sensitivity of atom-interferometric gyroscopes depends on the area enclosed by the interferometer. In this contribution, we present a concept for a rotation sensor, utilizing a multi-loop interferometer geometry to achieve a scalable area while maintaining a compact setup. It enables rotation measurements of a single axis on ground and can be extended to measure rotations along all three spatial axes in microgravity, for potential applications in space missions, Earth observation, and navigation systems.
We realize beam splitters and mirrors for atom waves by employing a sequence of light pulses rather than individual ones. In this way we can tailor atom interferometers with improved sensitivity and accuracy. We demonstrate our method of composite pulses by creating a symmetric matter-wave interferometer which combines the advantages of conventional Bragg- and Raman-type concepts. This feature leads to an interferometer with a high immunity to technical noise allowing us to devise a large-area Sagnac gyroscope yielding a phase shift of 6.5 rad due to the Earth's rotation. With this device we achieve a rotation rate precision of 120 nrad s(-1) Hz(-1/2) and determine the Earth's rotation rate with a relative uncertainty of 1.2%.
We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.
Since the first atom interferometry experiments in 1991, measurements of rotation through the Sagnac effect in open-area atom interferometers have been investigated. These studies have demonstrated very high sensitivity that can compete with state-of-the-art optical Sagnac interferometers. Since the early 2000s, these developments have been motivated by possible applications in inertial guidance and geophysics. Most matter-wave interferometers that have been investigated since then are based on two-photon Raman transitions for the manipulation of atomic wave packets. Results from the two most studied configurations, a space-domain interferometer with atomic beams and a time-domain interferometer with cold atoms, are presented and compared. Finally, the latest generation of cold atom interferometers and their preliminary results are presented.
We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.
The Sagnac effect, manifest in the phase shift of a rotating interferometer proportional to its physical area and to the rotation rate of the frame, plays a crucial role in modern physics being generalized to any kind of interferometer. However, as compared to light, the accurate experimental validation of the Sagnac effect for matter-waves remains challenging. We report the accurate measurement of the Sagnac phase shift, induced by the Earth’s rotation, using a large-area cold atom interferometer. We probe the atomic Sagnac phase shift along the two orthogonal horizontal axes in various orientation of the sensor with respect to geographic north and obtain an agreement with the theoretical prediction at the 20 ppm level, improving by twenty five-fold over the previous achievements for matter waves. Our results underline the universality of the Sagnac effect and open new horizons for testing other fundamental theories, as well as for a number of technological applications in seismology, geodesy and inertial navigation systems.