Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2303.02143 · Applied Physics Letters

Ablation loading of barium ions into a surface-electrode trap

Xiaoyang Shi, Susanna Todaro, Gabriel Mintzer, Colin Bruzewicz, John Chiaverini, Isaac L. Chuang

Published Jun 26, 2023• 6 citations
arXivHTMLPDF

Abstract

Trapped-ion quantum information processing may benefit from qubits encoded in isotopes that are practically available in only small quantities, e.g., due to low natural abundance or radioactivity. Laser ablation provides a method of controllably liberating neutral atoms or ions from low-volume targets, but energetic ablation products can be difficult to confine in the small ion-electrode distance, micron-scale microfabricated traps amenable to high-speed, high-fidelity manipulation of ion arrays. Here, we investigate ablation-based ion loading into surface-electrode traps of different sizes to test a model describing ion loading probability as a function of effective trap volume and other trap parameters. We characterize loading of ablated barium from a metallic source in two cryogenic surface-electrode traps with 730 and 50 μm ion-electrode distances. Our loading rate agrees with a predictive analytical model, providing insight for the confinement of limited-quantity species of interest for quantum computing, simulation, and sensing.

DOI
10.1063/5.0149778

Related papers

Microgram BaCl2 ablation targets for trapped ion experiments

Noah Greenberg, Akbar Jahangiri Jozani, Collin J. C. Epstein +3 more

Trapped ions for quantum information processing have been an area of intense study due to the extraordinarily high fidelity operations that have been reported experimentally. Specifically, barium trapped ions have been shown to have exceptional state-preparation and measurement fidelities. The 133Ba+ (I = 1/2) isotope in particular is a promising candidate for large-scale quantum computing experiments. However, a major pitfall with this isotope is that it is radioactive and is thus generally used in microgram quantities to satisfy safety regulations. We describe a new method for creating microgram barium chloride (BaCl2) ablation targets for use in trapped ion experiments and compare our procedure to previous methods. We outline two recipes for the fabrication of ablation targets that increase the production of neutral atoms for isotope-selective loading of barium ions. We show that heat-treatment of the ablation targets greatly increases the consistency at which neutral atoms can be produced, and we characterize the uniformity of these targets using trap-independent techniques such as energy dispersive x-ray spectroscopy and neutral fluorescence collection. Our comparison between fabrication techniques and the demonstration of consistent neutral fluorescence paves a path toward reliable loading of 133Ba+ in surface traps and opens opportunities for scalable quantum computing with this isotope.

Review of Scientific Instruments•Apr 1, 2024•2 citations

Isotope-selective laser ablation ion-trap loading of Ba+137 using a BaCl2 target

Brendan White, Pei Jiang Low, Yvette de Sereville +4 more

The $^{133}\mathrm{Ba}^{+}$ ion is a promising candidate as a high-fidelity qubit, and the $^{137}\mathrm{Ba}^{+}$ isotope is promising as a high-fidelity qudit $(d>2)$. Barium metal is very reactive, and $^{133}\mathrm{Ba}^{+}$ is radioactive and can only be sourced in small quantities, so the most commonly used loading method, oven heating, is less suited for barium and is currently not possible for $^{133}\mathrm{Ba}^{+}$. Pulsed laser ablation solves both of these problems by utilizing compound barium sources while also giving some distinct advantages, such as fast loading, less displaced material, and lower heat load near the ion trap. Because of the relatively low abundances of the isotopes of interest, a two-step photoionization technique is used, which gives us the ability to selectively load isotopes. Characterization of the ablation process for our ${\mathrm{BaCl}}_{2}$ targets are presented, including observation of neutral and ion ablation-fluence regimes, preparation and conditioning, lifetimes of ablation spots, and plume velocity distributions. We show that by using laser ablation on ${\mathrm{BaCl}}_{2}$ salt targets with a two-step photoionization method, we can produce and trap barium ions reliably. Furthermore, we demonstrate that with our photoionization method, we can trap $^{137}\mathrm{Ba}^{+}$ with an enhanced selectivity compared to its natural abundance.

arXiv:2110.08456•Physical Review A•Mar 9, 2022•15 citations

Efficient isotope-selective pulsed laser ablation loading of 174Yb+ ions in a surface electrode trap

Geert Vrijsen, Yuhi Aikyo, Robert Spivey +2 more

ions in a surface electrode ion trap by using single pulses from a Q-switched Nd:YAG laser to ablate neutral atoms, combined with a two-photon photo-ionization process. The method is three orders of magnitude faster to load a single ion as compared to traditional resistively heated sources and can load large collections of ions in seconds. The negligible thermal load of this method enables the use of this ablation-based loading scheme in ion traps operating under cryogenic conditions.

Optics Express•Nov 5, 2019•24 citations

Microgram $\mathrm{BaCl}_2$ Ablation Targets for Trapped Ion Experiments

Greenberg, Noah, Akbar Jahangiri Jozani, Collin J. C. Epstein +3 more

Trapped ions for quantum information processing has been an area of intense study due to the extraordinarily high fidelity operations that have been reported experimentally. Specifically, barium trapped ions have been shown to have exceptional state-preparation and measurement (SPAM) fidelities. The $^{133}\mathrm{Ba}^+$ ($I = 1/2$) isotope in particular is a promising candidate for large-scale quantum computing experiments. However, a major pitfall with this isotope is that it is radioactive and is thus generally used in microgram quantities to satisfy safety regulations. We describe a new method for creating microgram barium chloride ($\mathrm{BaCl}_2$) ablation targets for use in trapped ion experiments and compare our procedure to previous methods. We outline two recipes for fabrication of ablation targets that increase the production of neutral atoms for isotope-selective loading of barium ions. We show that heat-treatment of the ablation targets greatly increases the consistency at which neutral atoms can be produced and we characterize the uniformity of these targets using trap-independent techniques such as energy dispersive x-ray spectroscopy (EDS) and neutral fluorescence collection. Our comparison between fabrication techniques and demonstration of consistent neutral fluorescence paves a path towards reliable loading of $^{133}\mathrm{Ba}^+$ in surface traps and opens opportunities for scalable quantum computing with this isotope.

arXiv:2402.06632•Jan 16, 2024•0 citations

Loading of a surface-electrode ion trap from a remote, precooled source

Jeremy Sage, Andrew J. Kerman, John Chiaverini

We demonstrate loading of ions into a surface-electrode trap (SET) from a remote, laser-cooled source of neutral atoms. We first cool and load $\ensuremath{\sim}$${10}^{6}$ neutral ${}^{88}$Sr atoms into a magneto-optical trap from an oven that has no line of sight with the SET. The cold atoms are then pushed with a resonant laser into the trap region where they are subsequently photoionized and trapped in an SET operated at a cryogenic temperature of 4.6 K. We present studies of the loading process and show that our technique achieves ion loading into a shallow (15 meV depth) trap at rates as high as 125 ions/s while drastically reducing the amount of metal deposition on the trap surface as compared with direct loading from a hot vapor. Furthermore, we note that due to multiple stages of isotopic filtering in our loading process, this technique has the potential for enhanced isotopic selectivity over other loading methods. Rapid loading from a clean, isotopically pure, and precooled source may enable scalable quantum-information processing with trapped ions in large, low-depth surface-trap arrays that are not amenable to loading from a hot atomic beam.

arXiv:1205.6379•Physical Review A•Jul 20, 2012•48 citations

Deterministic loading of a single strontium ion into a surface electrode trap using pulsed laser ablation

Alto Osada, Atsushi Noguchi

Abstract Trapped-ion quantum technologies have been developed for decades toward applications such as precision measurement, quantum communication and quantum computation. Coherent manipulation of ions’ oscillatory motions in an ion trap is important for quantum information processing by ions, however, unwanted decoherence caused by fluctuating electric-field environment often hinders stable and high-fidelity operations. One way to avoid this is to adopt pulsed laser ablation for ion loading, a loading method with significantly reduced pollution and heat production. Despite the usefulness of the ablation loading such as the compatibility with cryogenic environment, randomness of the number of loaded ions is still problematic in realistic applications where definite number of ions are preferably loaded with high probability. In this paper, we demonstrate an efficient loading of a single strontium ion into a surface electrode trap generated by laser ablation and successive photoionization. The probability of single-ion loading into a surface electrode trap is measured to be 82%, and such a deterministic single-ion loading allows for loading ions into the trap one-by-one. Our results open up a way to develop more functional ion-trap quantum devices by the clean, stable, and deterministic ion loading.

arXiv:2109.04965•Journal of Physics Communications•Jan 1, 2022•7 citations
Trapped-ion quantum information processing may benefit from qubits encoded in isotopes that are practically available in only small quantities, e.g., due to low natural abundance or radioactivity. Laser ablation provides a method of controllably liberating neutral atoms or ions from low-volume targets, but energetic ablation products can be difficult to confine in the small ion-electrode distance, micron-scale microfabricated traps amenable to high-speed, high-fidelity manipulation of ion arrays. Here, we investigate ablation-based ion loading into surface-electrode traps of different sizes to test a model describing ion loading probability as a function of effective trap volume and other trap parameters. We characterize loading of ablated barium from a metallic source in two cryogenic surface-electrode traps with 730 and 50 μm ion-electrode distances. Our loading rate agrees with a predictive analytical model, providing insight for the confinement of limited-quantity species of interest for quantum computing, simulation, and sensing.
Trapped ions for quantum information processing have been an area of intense study due to the extraordinarily high fidelity operations that have been reported experimentally. Specifically, barium trapped ions have been shown to have exceptional state-preparation and measurement fidelities. The 133Ba+ (I = 1/2) isotope in particular is a promising candidate for large-scale quantum computing experiments. However, a major pitfall with this isotope is that it is radioactive and is thus generally used in microgram quantities to satisfy safety regulations. We describe a new method for creating microgram barium chloride (BaCl2) ablation targets for use in trapped ion experiments and compare our procedure to previous methods. We outline two recipes for the fabrication of ablation targets that increase the production of neutral atoms for isotope-selective loading of barium ions. We show that heat-treatment of the ablation targets greatly increases the consistency at which neutral atoms can be produced, and we characterize the uniformity of these targets using trap-independent techniques such as energy dispersive x-ray spectroscopy and neutral fluorescence collection. Our comparison between fabrication techniques and the demonstration of consistent neutral fluorescence paves a path toward reliable loading of 133Ba+ in surface traps and opens opportunities for scalable quantum computing with this isotope.
The 133Ba+^{133}\mathrm{Ba}^{+}133Ba+ ion is a promising candidate as a high-fidelity qubit, and the 137Ba+^{137}\mathrm{Ba}^{+}137Ba+ isotope is promising as a high-fidelity qudit (d>2)(d>2)(d>2). Barium metal is very reactive, and 133Ba+^{133}\mathrm{Ba}^{+}133Ba+ is radioactive and can only be sourced in small quantities, so the most commonly used loading method, oven heating, is less suited for barium and is currently not possible for 133Ba+^{133}\mathrm{Ba}^{+}133Ba+. Pulsed laser ablation solves both of these problems by utilizing compound barium sources while also giving some distinct advantages, such as fast loading, less displaced material, and lower heat load near the ion trap. Because of the relatively low abundances of the isotopes of interest, a two-step photoionization technique is used, which gives us the ability to selectively load isotopes. Characterization of the ablation process for our BaCl2{\mathrm{BaCl}}_{2}BaCl2​ targets are presented, including observation of neutral and ion ablation-fluence regimes, preparation and conditioning, lifetimes of ablation spots, and plume velocity distributions. We show that by using laser ablation on BaCl2{\mathrm{BaCl}}_{2}BaCl2​ salt targets with a two-step photoionization method, we can produce and trap barium ions reliably. Furthermore, we demonstrate that with our photoionization method, we can trap 137Ba+^{137}\mathrm{Ba}^{+}137Ba+ with an enhanced selectivity compared to its natural abundance.
Microgram BaCl2\mathrm{BaCl}_2BaCl2​ Ablation Targets for Trapped Ion Experiments
Trapped ions for quantum information processing has been an area of intense study due to the extraordinarily high fidelity operations that have been reported experimentally. Specifically, barium trapped ions have been shown to have exceptional state-preparation and measurement (SPAM) fidelities. The 133Ba+^{133}\mathrm{Ba}^+133Ba+ (I=1/2I = 1/2I=1/2) isotope in particular is a promising candidate for large-scale quantum computing experiments. However, a major pitfall with this isotope is that it is radioactive and is thus generally used in microgram quantities to satisfy safety regulations. We describe a new method for creating microgram barium chloride (BaCl2\mathrm{BaCl}_2BaCl2​) ablation targets for use in trapped ion experiments and compare our procedure to previous methods. We outline two recipes for fabrication of ablation targets that increase the production of neutral atoms for isotope-selective loading of barium ions. We show that heat-treatment of the ablation targets greatly increases the consistency at which neutral atoms can be produced and we characterize the uniformity of these targets using trap-independent techniques such as energy dispersive x-ray spectroscopy (EDS) and neutral fluorescence collection. Our comparison between fabrication techniques and demonstration of consistent neutral fluorescence paves a path towards reliable loading of 133Ba+^{133}\mathrm{Ba}^+133Ba+ in surface traps and opens opportunities for scalable quantum computing with this isotope.
We demonstrate loading of ions into a surface-electrode trap (SET) from a remote, laser-cooled source of neutral atoms. We first cool and load $\ensuremath{\sim}$106{10}^{6}106 neutral 88{}^{88}88Sr atoms into a magneto-optical trap from an oven that has no line of sight with the SET. The cold atoms are then pushed with a resonant laser into the trap region where they are subsequently photoionized and trapped in an SET operated at a cryogenic temperature of 4.6 K. We present studies of the loading process and show that our technique achieves ion loading into a shallow (15 meV depth) trap at rates as high as 125 ions/s while drastically reducing the amount of metal deposition on the trap surface as compared with direct loading from a hot vapor. Furthermore, we note that due to multiple stages of isotopic filtering in our loading process, this technique has the potential for enhanced isotopic selectivity over other loading methods. Rapid loading from a clean, isotopically pure, and precooled source may enable scalable quantum-information processing with trapped ions in large, low-depth surface-trap arrays that are not amenable to loading from a hot atomic beam.
Abstract Trapped-ion quantum technologies have been developed for decades toward applications such as precision measurement, quantum communication and quantum computation. Coherent manipulation of ions’ oscillatory motions in an ion trap is important for quantum information processing by ions, however, unwanted decoherence caused by fluctuating electric-field environment often hinders stable and high-fidelity operations. One way to avoid this is to adopt pulsed laser ablation for ion loading, a loading method with significantly reduced pollution and heat production. Despite the usefulness of the ablation loading such as the compatibility with cryogenic environment, randomness of the number of loaded ions is still problematic in realistic applications where definite number of ions are preferably loaded with high probability. In this paper, we demonstrate an efficient loading of a single strontium ion into a surface electrode trap generated by laser ablation and successive photoionization. The probability of single-ion loading into a surface electrode trap is measured to be 82%, and such a deterministic single-ion loading allows for loading ions into the trap one-by-one. Our results open up a way to develop more functional ion-trap quantum devices by the clean, stable, and deterministic ion loading.