Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2303.00990

Optimizing the phase sensitivity of a Michelson interferometer with a two mode squeezed coherent input

Stav Haldar, Pratik J. Barge, Xiao-Qi Xiao, Hwang Lee

Published Mar 2, 2023• 0 citations
arXivHTMLPDF

Abstract

A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of $e^{2r}$, where $r$ is the squeezing parameter [Phys. Rev. A 102,022614 (2020)]. We show that when photon loss and noise in the two arms is asymmetric an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up to 80\%. Hence, a significant improvement can be made in several applications such as LiDAR, gyroscopes and measuring refractive indices of highly absorptive/reflective materials.

DOI
10.48550/arxiv.2303.00990

Related papers

Optimizing the phase sensitivity of Michelson interferometer with two-mode squeezed coherent input in the presence of loss and noise

Stav Haldar, Pratik J. Barge, Xiao-Qi Xiao +1 more

A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of e2r, where r is the squeezing parameter [Phys. Rev. A 102, 022614 (2020)]. We show that when photon loss and noise in the two arms are asymmetric, an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up to 80%. Hence, a significant improvement can be made in several applications such as LiDAR, gyroscopes, and measuring refractive indices of highly absorptive/reflective materials.

AVS Quantum Science•Jul 5, 2023•2 citations

Enhanced phase estimation with coherently boosted two-mode squeezed beams and its application to optical gyroscopes

Xiao-Qi Xiao, Elisha S. Matekole, Jiankang Zhao +3 more

Quantum techniques, developed in recent decades, provide new approaches to achieving high-precision measurements beyond the classical bounds. In this paper, we theoretically demonstrate a metrology method for improving the sensitivity of the interferometric optical gyroscope, robust against the loss, by using coherent-light stimulated two-mode squeezed beams as the light source. The detection protocol is based on a simple intensity measurement, and the quantum noise is far below the shot-noise limit. The enhancement factors for different coherent light fields are analyzed in detail. Additionally, the influence of loss during the propagation in the optical path is studied, and the conditions for achieving sub-shot-noise measurement sensitivity are obtained. We also find that the phase sensitivity of the proposed gyroscope scheme becomes closer to the quantum Cramér-Rao bound with increasing of the photon number of the coherent beams.

quant-pharXiv:2607.05732•Physical Review A•Jul 8, 2026•8 citations

Sub-shot-noise-limited phase estimation via single-mode inputs

Jiandong Zhang, Chenglong You, Shuai Wang

In 1981, Caves pointed out that the phase sensitivity of a Mach-Zehnder interferometer with single-mode inputs is bounded by the shot-noise limit. The quantum Fisher information analysis shows that this statement holds true for the scenario where two antisymmetric phase shifts occur in two arms, but it is invalid for the scenario where an unknown phase is embedded in one of two arms. In this paper, we focus on the phase sensitivity directed against the latter scenario. The optimal single-mode input is discussed by analyzing common states, including displaced squeezed states, displaced number states, squeezed number states, Schrödinger cat states and completely mixed states. We find that the best choice is a squeezed vacuum state and show the specific measurement scheme which is capable of saturating the corresponding phase sensitivity limit. In addition, we study the effects of several realistic factors-anti-squeezing noise, photon loss and dark counts-on the phase sensitivity. Our results suggest that sub-shot-noise-limited phase sensitivity is attainable with low noise or loss, which paves the way for practical metrology.

Optics Express•Oct 24, 2022•2 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

High sensitivity quantum Michelson interferometer

Zuo Xiao-Jie, Sun Ying-Rong, Yan Zhi-Hui +1 more

Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.

Acta Physica Sinica•Jan 1, 2018•3 citations

Quantum limit of precision for phase estimation in squeezing-enhanced interferometry with a single-mode readout

Dmitri B. Horoshko, Fedor Jelezko

We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We find the ultimate limit of precision for such an interferometer by calculating the quantum Fisher information of the mixed quantum state in one of the interferometer's outputs about the difference phase. We show that, in the vicinity of the black fringe, this information is asymptotically close to the quantum Fisher information about this phase for the two-mode readout. We conclude that the single-mode readout is optimal for phase estimation in squeezing-enhanced interferometry and allows for the Heisenberg scaling of precision. We also show that the optimal local measurement in the vicinity of the black fringe consists of amplifying the output field in a phase-sensitive way and measuring its photon number.

quant-pharXiv:2603.07556•Mar 10, 2026•0 citations
A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of e2re^{2r}e2r, where rrr is the squeezing parameter [Phys. Rev. A 102,022614 (2020)]. We show that when photon loss and noise in the two arms is asymmetric an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up to 80%. Hence, a significant improvement can be made in several applications such as LiDAR, gyroscopes and measuring refractive indices of highly absorptive/reflective materials.
A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of e2r, where r is the squeezing parameter [Phys. Rev. A 102, 022614 (2020)]. We show that when photon loss and noise in the two arms are asymmetric, an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up to 80%. Hence, a significant improvement can be made in several applications such as LiDAR, gyroscopes, and measuring refractive indices of highly absorptive/reflective materials.
Quantum techniques, developed in recent decades, provide new approaches to achieving high-precision measurements beyond the classical bounds. In this paper, we theoretically demonstrate a metrology method for improving the sensitivity of the interferometric optical gyroscope, robust against the loss, by using coherent-light stimulated two-mode squeezed beams as the light source. The detection protocol is based on a simple intensity measurement, and the quantum noise is far below the shot-noise limit. The enhancement factors for different coherent light fields are analyzed in detail. Additionally, the influence of loss during the propagation in the optical path is studied, and the conditions for achieving sub-shot-noise measurement sensitivity are obtained. We also find that the phase sensitivity of the proposed gyroscope scheme becomes closer to the quantum Cramér-Rao bound with increasing of the photon number of the coherent beams.
In 1981, Caves pointed out that the phase sensitivity of a Mach-Zehnder interferometer with single-mode inputs is bounded by the shot-noise limit. The quantum Fisher information analysis shows that this statement holds true for the scenario where two antisymmetric phase shifts occur in two arms, but it is invalid for the scenario where an unknown phase is embedded in one of two arms. In this paper, we focus on the phase sensitivity directed against the latter scenario. The optimal single-mode input is discussed by analyzing common states, including displaced squeezed states, displaced number states, squeezed number states, Schrödinger cat states and completely mixed states. We find that the best choice is a squeezed vacuum state and show the specific measurement scheme which is capable of saturating the corresponding phase sensitivity limit. In addition, we study the effects of several realistic factors-anti-squeezing noise, photon loss and dark counts-on the phase sensitivity. Our results suggest that sub-shot-noise-limited phase sensitivity is attainable with low noise or loss, which paves the way for practical metrology.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.
We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We find the ultimate limit of precision for such an interferometer by calculating the quantum Fisher information of the mixed quantum state in one of the interferometer's outputs about the difference phase. We show that, in the vicinity of the black fringe, this information is asymptotically close to the quantum Fisher information about this phase for the two-mode readout. We conclude that the single-mode readout is optimal for phase estimation in squeezing-enhanced interferometry and allows for the Heisenberg scaling of precision. We also show that the optimal local measurement in the vicinity of the black fringe consists of amplifying the output field in a phase-sensitive way and measuring its photon number.