Josephson traveling-wave parametric amplifiers (TWPAs) enable the amplification of weak microwave signals close to the quantum limit with large bandwidth, which has a broad range of applications in superconducting quantum computing and in the operation of single-photon detectors. While the large bandwidth allows for their use in frequency-multiplexed detection architectures, an increased number of readout tones per amplifier puts more stringent requirements on the dynamic range to avoid saturation. Here, we characterize the undesired mixing processes between the different frequency-multiplexed tones applied to a Josephson TWPA, a phenomenon also known as intermodulation distortion. The effect becomes particularly significant when the amplifier is operated close to its saturation power. Furthermore, we demonstrate that intermodulation distortion can lead to significant crosstalk and reduction of fidelity for multiplexed readout of superconducting qubits. We suggest using large detunings between the pump and signal frequencies to mitigate crosstalk. Our work provides insights into the limitations of current Josephson TWPAs and highlights the importance of performing further research on these devices.
Josephson traveling-wave parametric amplifiers (TWPAs) enable the amplification of weak microwave signals close to the quantum limit with large bandwidth, which has a broad range of applications in superconducting quantum computing and in the operation of single-photon detectors. While the large bandwidth allows for their use in frequency-multiplexed detection architectures, an increased number of readout tones per amplifier puts more stringent requirements on the dynamic range to avoid saturation. Here, we characterize the undesired mixing processes between the different frequency-multiplexed tones applied to a Josephson TWPA, a phenomenon also known as intermodulation distortion. The effect becomes particularly significant when the amplifier is operated close to its saturation power. Furthermore, we demonstrate that intermodulation distortion can lead to significant crosstalk and reduction of fidelity for multiplexed readout of superconducting qubits. We suggest using large detunings between the pump and signal frequencies to mitigate crosstalk. Our work provides insights into the limitations of current Josephson TWPAs and highlights the importance of performing further research on these devices.
Superconducting traveling-wave parametric amplifiers (TWPAs) are increasingly used in various applications, including quantum computing, quantum sensing, and dark matter detection. However, one important characteristic of these amplifiers, gain compression, has not received much attention. As a result, there is a lack of comprehensive experimental exploration of this phenomenon in the existing literature. In this study, we present an experimental investigation of gain compression in a Josephson traveling-wave parametric amplifier based on a four-wave mixing process. We have implemented a novel setup to monitor the complex transmission of both the pump and signal tones, which allows us to simultaneously track pump depletion and signal amplification as functions of signal power and frequency across the entire bandwidth of the device. Our findings indicate that, while pump depletion occurs during gain compression, it is not the only mechanism involved in the saturation of a TWPA. Power-induced phase-matching processes also take place within the device. This study provides valuable insights for optimizing TWPAs for applications that require high total input power, such as multiplexed qubit readout or broadband photon emission.
Superconducting traveling-wave parametric amplifiers (TWPAs) are increasingly used in various applications, including quantum computing, quantum sensing, and dark matter detection. However, one important characteristic of these amplifiers, gain compression, has not received much attention. As a result, there is a lack of comprehensive experimental exploration of this phenomenon in the existing literature. In this study, we present an experimental investigation of gain compression in a Josephson traveling-wave parametric amplifier based on a four-wave mixing process. We have implemented a novel setup to monitor the complex transmission of both the pump and signal tones, which allows us to simultaneously track pump depletion and signal amplification as functions of signal power and frequency across the entire bandwidth of the device. Our findings indicate that, while pump depletion occurs during gain compression, it is not the only mechanism involved in the saturation of a TWPA. Power-induced phase-matching processes also take place within the device. This study provides valuable insights for optimizing TWPAs for applications that require high total input power, such as multiplexed qubit readout or broadband photon emission.
Bringing signals from quantum to classical, from few-photon to many-photon levels for further processing, is a common challenge in rising quantum technologies. These include quantum computing, quantum communication, quantum sensing, radio astronomy, and dark matter searches, typically operating at microwave frequencies and millikelvin temperatures. Superconducting parametric amplifiers, as the first piece in the readout chain, have become a cornerstone of these technologies, since they offer unrivaled noise performance near the quantum-mechanical limit and high gain to surpass the noise of subsequent amplifiers. A notable implementation is the Josephson traveling-wave parametric amplifier (TWPA), which stands out due to its bandwidth of several Gigahertz and high saturation power, often larger than -100 dBm. These key properties come at the cost of complexity in design and fabrication: TWPA metamaterials often contain several thousands of Josephson junctions. Designing high-gain TWPAs involves three major challenges: ensuring impedance-matching, phase-matching of parametric amplification, and suppressing unwanted processes, all achievable through sub-wavelength dispersion engineering. This thesis covers the circuit design and analysis, implementation, and experimental characterization of a dispersion-engineered TWPA based on radio-frequency superconducting interference devices (rf-SQUIDs). It focuses on a detailed investigation of dispersion-engineering techniques and their effects on amplifier performance, particularly through the use of time-domain circuit simulations to analyze the multimode dynamics of the circuit. The experimentally realized device features 18 dB of gain, an instantaneous bandwidth spanning from 2.2 to 6.7 GHz, a system noise of 2.5 quanta, and a saturation power of (−86.5 ± 4.0) dBm. With these characteristics, it is suitable for frequency-multiplexed readout of detector arrays or qubits. Its high saturation power, about 10 dB higher than other reported Josephson-junction-based TWPAs, allows increasing the number of qubits per readout line, or decreasing the intermodulation between frequency-multiplexed qubits, both crucial for scaling up quantum computation.
Abstract A Josephson traveling-wave parametric amplifier (JTWPA) is indispensable for the high-fidelity readout of superconducting qubits, owing to its broadband gain and near-quantum-limited noise performance. Conventional JTWPAs implemented with 0-Josephson junctions (0-JTWPAs) avoid magnetic-flux bias but rely on Kerr nonlinearity, which leads to pump-power-dependent phase mismatch, gain ripple, and a limited dynamic range. More recently, three-wave-mixing (3WM) JTWPAs employing flux-biased rf-SQUIDs have been proposed to suppress Kerr effects. However, these designs require a significant external flux bias per unit cell, which complicates cryogenic hardware, introduces sensitivity to flux noise, and limits scalability in large arrays. In this study, we propose and analyze a π -junction-based JTWPA ( π -JTWPA) in which the intrinsic π phase shift of the junction effectively displaces the operating point of the current–phase relation. This approach aims to realize 3WM-type nonlinearity with reduced flux bias while preserving broadband amplification, thereby simplifying flux-bias distribution, enhancing robustness against flux noise, and providing a pathway toward scalable, multiplexed quantum readout architectures. In addition, we examine the potential applicability of the π -JTWPA in four-wave-mixing (4WM) operation.
In order to build a large-scale quantum computer, one of the requirements is high-fidelity
multiplexed qubit readout, which in turn relies on the use of ultralow-noise
amplifiers. While Josephson Parametric Amplifiers (JPAs), using a cavity with
few Josephson junctions, have shown promising results for single qubit readout,
they have limitations such as low saturation power and a gain-bandwidth product
restriction. This makes them less suited for frequency multiplexed qubit readout. A
current-pumped Josephson Travelling-Wave Parametric Amplifier (JTWPA), using
4-wave mixing in a lumped-element transmission line, features both high saturation
power as well as no restriction on large bandwidth and high gain. This is possible
due to multiple junctions and the lack of a cavity. However, also this current pumped
JTWPA has an inherent problem, namely phase mismatch between the pump and
the signal. This prevents exponential gain. In this thesis, a current pumped JTWPA
using the resonant phase matching (RPM) technique to reduce the phase mismatch
problem is studied and characterised. The JTWPA shows high gain, high saturation
power and a large signal-to-noise ratio improvement. The JTWPA is also used for
qubit readout, for which it clearly improves the readout fidelity.
The recent developments in quantum technologies, as well as advanced detection experiments, have raised the need to detect extremely weak signals in the microwave frequency spectrum. To this aim, the Josephson travelling wave parametric amplifier, a device capable of reaching the quantum noise limit while providing a wide bandwidth, has been proposed as a suitable cryogenic front-end amplifier. This work deals with the numerical study of a Josephson travelling wave parametric amplifier, without approximations regarding the nonlinearity of the key elements. In particular, we focus on the investigation of the system of coupled nonlinear differential equations representing all the cells of the Josephson travelling wave parametric amplifier, with proper input and output signals at the boundaries. The investigation of the output signals generated by the parametric amplification process explores the phase-space and the Fourier spectral analysis of the output voltage, as a function of the parameters describing the pump and signal tones that excite the device. Beside the expected behavior, i.e., the signal amplification, we show that, depending on the system operation, unwanted effects (such as pump tone harmonics, incommensurate frequency generation, and noise rise), which are not accounted for in simple linearized approaches, can be generated in the whole nonlinear system.