Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2206.15440

A Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity

Scott T. Alsid, Jennifer M. Schloss, Matthew Steinecker, John F. Barry, Andrew C. Maccabe, Guoqing Wang, Paola Cappellaro, Danielle Braje

Published Jun 30, 2022• 1 citation
arXivHTMLPDF

Abstract

Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/$\sqrt{\textrm{Hz}}$. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.

DOI
10.48550/arxiv.2206.15440

Related papers

Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity

Scott T. Alsid, Jennifer M. Schloss, Matthew Steinecker +5 more

Magnetometry with diamond nitrogen-vacancy (NV) ensembles has enabled devices with picotesla sensitivity at static and low-frequency fields, but their performance at higher frequencies lags far behind. The authors solve the technical challenges and demonstrate a microwave-frequency NV magnetometer with picotesla sensitivity, by implementing a pulse scheme for noise cancellation and employing a custom-grown diamond. This sensitivity enhancement could be extended into a far broader range of frequencies using spin-locking and quantum frequency mixing. These results could lead to applications such as near-field antenna characterization and microwave circuitry imaging.

Physical Review Applied•May 31, 2023•29 citations

A Sub-10 pT·Hz –1/2 Diamond Quantum Sensor with 1/ f Noise Suppression Using 561 nm Laser Excitation

Xiao Peng, Qihui Liu, Chengyu Yang +9 more

The nitrogen–vacancy center in diamond enables highly sensitive magnetic-field measurements. In this work, we demonstrate an excellent sensitivity of 7.9 pT·Hz –1/2 in the near-DC range of 1 to 1000 Hz. This performance is achieved using a 35 mW laser power and 1 mW microwave power enabled by 561 nm laser excitation and the resonant-antenna design. By leveraging dual resonance with intrinsic π shift for real-time common-mode rejection, this technique effectively suppresses low-frequency noise and pushes the 1/ f corner frequency down to 1 Hz, with a measured sensitivity at 1 Hz of 10.6 pT·Hz –1/2 . The magnetometer also exhibits excellent capability in detecting magnetic anomalies, promoting the practical use of diamond quantum sensors in biomedical, geophysical, and other real-world applications.

ACS Photonics•Mar 24, 2026•3 citations

Highly sensitive diamond quantum sensor with large sensor volume toward magnetoencephalography

雄太 増山, Takayuki Iwasaki, 睦子 波多野 +4 more

Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.

•Dec 4, 2019•0 citations

High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles

Ronald Lee Walsworth, Zechuan Yin, Justin J. Welter +2 more

Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

•Jan 24, 2025•0 citations

High-resolution and wide-frequency-range magnetic spectroscopy with solid-state spin ensembles

Zechuan Yin, Justin J. Welter, Connor Hart +2 more

Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

npj Quantum Information•Dec 3, 2025•2 citations

Tunable double split-ring resonator for quantum sensing using nitrogen-vacancy centers in diamond

Yan Yang, Qin Wu, Yangpeng Wang +5 more

For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.

Optics Continuum•May 16, 2023•10 citations
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as ∼\sim∼1 pT/Hz\sqrt{\text{Hz}}Hz​. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/Hz\sqrt{\text{Hz}}Hz​ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/Hz\sqrt{\textrm{Hz}}Hz​. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.
Magnetometry with diamond nitrogen-vacancy (NV) ensembles has enabled devices with picotesla sensitivity at static and low-frequency fields, but their performance at higher frequencies lags far behind. The authors solve the technical challenges and demonstrate a microwave-frequency NV magnetometer with picotesla sensitivity, by implementing a pulse scheme for noise cancellation and employing a custom-grown diamond. This sensitivity enhancement could be extended into a far broader range of frequencies using spin-locking and quantum frequency mixing. These results could lead to applications such as near-field antenna characterization and microwave circuitry imaging.
The nitrogen–vacancy center in diamond enables highly sensitive magnetic-field measurements. In this work, we demonstrate an excellent sensitivity of 7.9 pT·Hz –1/2 in the near-DC range of 1 to 1000 Hz. This performance is achieved using a 35 mW laser power and 1 mW microwave power enabled by 561 nm laser excitation and the resonant-antenna design. By leveraging dual resonance with intrinsic π shift for real-time common-mode rejection, this technique effectively suppresses low-frequency noise and pushes the 1/ f corner frequency down to 1 Hz, with a measured sensitivity at 1 Hz of 10.6 pT·Hz –1/2 . The magnetometer also exhibits excellent capability in detecting magnetic anomalies, promoting the practical use of diamond quantum sensors in biomedical, geophysical, and other real-world applications.
Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.