Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2203.10815 · Physical review. D/Physical review. D.

Improving the stability of frequency-dependent squeezing with bichromatic control of filter cavity length, alignment, and incident beam pointing

Yang Zhao, E. Capocasa, M. Eisenmann, N. Aritomi, M. A. Page, Yuefan Guo, E. Polini, Koji Arai, Y. Aso, M. van Beuzekom, Y-C. Huang, Ray‐Kuang Lee, Harald Lück, O. Miyakawa, Pierre Prat, A. Shoda, Matteo Tacca, Ryutaro Takahashi, H. Vahlbruch, M. Vardaro, Chien-Ming Wu, M. Leonardi, M. Barsuglia, Raffaele Flaminio

Published Apr 26, 2022• 7 citations
arXivHTMLPDF

Abstract

Frequency-dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its line width. However, since the squeezed vacuum contains no classical amplitude, copropagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency-dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here, we report a stabilized filter cavity detuning variation of less than 10 Hz compared to the 113 Hz cavity line width. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020), such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from 11% to within 2%.

DOI
10.1103/physrevd.105.082003

Related papers

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

Yang Zhao, N. Aritomi, E. Capocasa +20 more

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

arXiv:2003.10672•Physical Review Letters•Apr 28, 2020•110 citations

Broadband quantum noise reduction via frequency dependent squeezing for Advanced Virgo Plus

E. Polini

Abstract Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.

Physica Scripta•May 7, 2021•2 citations

Frequency-Dependent Squeezing for Advanced LIGO

Lee P. McCuller, Chris Whittle, D. Ganapathy +13 more

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

arXiv:2003.13443•Physical Review Letters•Apr 28, 2020•191 citations

Broadband Quantum Noise Reduction In A Small-Scale Suspended Interferometer With Quantum Entangled Squeezed Beams

W. Ali, B. Garaventa, S. Di Pace +3 more

General relativity predicts the existence of gravitational waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, quantum noise poses a significant challenge for gravitational wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, shot noise (SN) predominates, while at lower frequencies, radiation-pressure noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. Starting from the observing run, O4 Virgo and LIGO have enhanced this method through frequency-dependent squeezing (FDS). By employing a 300-meter-long detuned filter cavity, the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. A promising alternative technique to reduce quantum noise across the entire sensitivity band uses Einstein-Podolsky-Rosen (EPR) quantum entanglement. This approach involves injecting two entangled squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a filter cavity and a gravitational wave detector. The Suspended Interferometer for Ponderomotive Squeezing (SIPS) adopts a large-scale GW detector layout, with a Michelson configuration and Fabry-Perot arm cavities. This system was initially thought to generate FDS in the GW frequency band using the ponderomotive technique. To enhance stability, a precise local control system was developed for the main optics of SIPS, which are suspended in a double pendulum configuration with monolithic fibers to reduce thermal noise. Advanced PXI-based data acquisition and position-sensitive detectors (PSDs) monitor angular and linear displacements, while real-time signal processing in LabVIEW enables corrective actuation, marking a significant step toward improved alignment and noise reduction in GW interferometry. The paper highlights the current status of SIPS, focusing on the local control strategy, underscoring its potential impact on the field.

International Journal of Environmental Sciences•Aug 4, 2025•0 citations

Control of a filter cavity with coherent control sidebands

N. Aritomi, M. Leonardi, E. Capocasa +2 more

For broadband quantum noise reduction of gravitational-wave detectors, frequency-dependent squeezed vacuum states realized using a filter cavity is a mature technique and will be implemented in Advanced LIGO and Advanced Virgo from the fourth observation run. To obtain the benefit of frequency-dependent squeezing, detuning and alignment of the filter cavity with respect to squeezed vacuum states must be controlled accurately. To this purpose, we suggest a new length and alignment control scheme, using coherent control sidebands which are already used to control the squeezing angle. Since both squeezed vacuum states and coherent control sidebands have the same mode matching conditions and almost the same frequency, detuning and alignment of the filter cavity can be controlled accurately with this scheme. In this paper, we show the principle of this scheme and its application to a gravitational-wave detector.

arXiv:2004.01400•Physical review. D/Physical review. D.•Aug 10, 2020•7 citations

Advanced techniques for squeezed-light-enhanced gravitational-wave detection

J. Gniesmer

Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.

•Jan 1, 2019•0 citations
Frequency-dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its line width. However, since the squeezed vacuum contains no classical amplitude, copropagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency-dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here, we report a stabilized filter cavity detuning variation of less than 10 Hz compared to the 113 Hz cavity line width. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020), such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from 11% to within 2%.
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
Abstract Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
General relativity predicts the existence of gravitational waves (GWs), ripples in spacetime that are now observable to highly sensitive interferometers. However, quantum noise poses a significant challenge for gravitational wave (GW) interferometers, influencing the entire bandwidth range (10-10,000 Hz) of the current GW detectors. At higher frequencies, shot noise (SN) predominates, while at lower frequencies, radiation-pressure noise (RPN) becomes the limiting factor, reducing both sensitivity and measurement precision. Squeezing techniques are implemented to address this issue by confining uncertainty within one quadrature of the light field. Starting from the observing run, O4 Virgo and LIGO have enhanced this method through frequency-dependent squeezing (FDS). By employing a 300-meter-long detuned filter cavity, the squeezing ellipse is rotated, allowing phase squeezing at high frequencies to reduce and amplitude squeezing at low frequencies to mitigate RPN, ultimately refining detection capabilities across the frequency spectrum. A promising alternative technique to reduce quantum noise across the entire sensitivity band uses Einstein-Podolsky-Rosen (EPR) quantum entanglement. This approach involves injecting two entangled squeezed beams at different frequencies into the dark port of the interferometer, enabling it to act as both a filter cavity and a gravitational wave detector. The Suspended Interferometer for Ponderomotive Squeezing (SIPS) adopts a large-scale GW detector layout, with a Michelson configuration and Fabry-Perot arm cavities. This system was initially thought to generate FDS in the GW frequency band using the ponderomotive technique. To enhance stability, a precise local control system was developed for the main optics of SIPS, which are suspended in a double pendulum configuration with monolithic fibers to reduce thermal noise. Advanced PXI-based data acquisition and position-sensitive detectors (PSDs) monitor angular and linear displacements, while real-time signal processing in LabVIEW enables corrective actuation, marking a significant step toward improved alignment and noise reduction in GW interferometry. The paper highlights the current status of SIPS, focusing on the local control strategy, underscoring its potential impact on the field.
For broadband quantum noise reduction of gravitational-wave detectors, frequency-dependent squeezed vacuum states realized using a filter cavity is a mature technique and will be implemented in Advanced LIGO and Advanced Virgo from the fourth observation run. To obtain the benefit of frequency-dependent squeezing, detuning and alignment of the filter cavity with respect to squeezed vacuum states must be controlled accurately. To this purpose, we suggest a new length and alignment control scheme, using coherent control sidebands which are already used to control the squeezing angle. Since both squeezed vacuum states and coherent control sidebands have the same mode matching conditions and almost the same frequency, detuning and alignment of the filter cavity can be controlled accurately with this scheme. In this paper, we show the principle of this scheme and its application to a gravitational-wave detector.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.