Quantum sensing on magnetic field inspired by Avian compass

Wei-Yin Chiang, Yuan‐Chung Cheng, Min-Hsiu Hsieh

Published Feb 24, 2022• 0 citations
arXivHTMLPDF

Abstract

Magnetic measurement can be performed by various sensors, such as SQUID and Giant Magnetoresistance. This device can achieve high accuracy while losing efficiency and convenience. The model of biological magnetic sensing in avian proposes a radical pair response to the external field on the FLY results in regulating animal behaviour. Inspired by the radical pair system found in biological system, the effect of intra-radical coupling and the initial condition is studied in this simplified radical pair model as the quantum advantage results from entanglement and superposition are investigated in metrology. To identify the sensing benefit from the cooperation between the radical pairs, the inter-radical coupling is considered. We find the intra-radical coupling determines the sensing regime while the coupled radical pair system enables a new sensing scheme that provides a more general and flexible way for magnetic sensing in a broader range through a easier manipulation to the system.

DOI
10.48550/arxiv.2202.11920

Related papers

Quantum control and entanglement in an avian chemical compass

Jianming Cai, Gian Giacomo Guerreschi, Hans J. Briegel

The radical pair mechanism is one of the two main hypotheses to explain the navigability of animals in weak magnetic fields, enabling e.g. birds to see the Earth's magnetic field. It also plays an essential role in the field of spin chemistry. Here, we show how quantum control can be used to either enhance or reduce the performance of such a chemical compass, providing a new route to further study the radical pair mechanism and its applications. We study the role of quantum entanglement in this mechanism, and demonstrate intriguing connections between radical-pair entanglement and the magnetic field sensitivity of the compass. Beyond their immediate application to the radical pair mechanism, these results also demonstrate how state-of-the-art quantum technologies could potentially be used to probe and control biological functions.

•Jun 12, 2009•0 citations

A precise measure of avian magnetoreception based on quantum metrology

Li-Sha Guo, Bao-Ming Xu, Jian Zou +1 more

The radical pair (RP) mechanism, which describes the quantum dynamics of a spatially separated electron pair, is considered as one of the principal models of avian magnetoreception. Different from the conventional phenomenological approach where the sensitivity of avian magnetoreception is characterized by the singlet yield $Φ_{S}$, we introduce the quantum Fisher information (QFI), which represents the maximum information about the magnetic field's direction extracted from the RP state, to give a precise measure of sensitivity of avian compass essentially. The consistency between our results and experimental observations suggests that QFI plays a decisive role in avian magnetoreception. Besides, within the framework of quantum metrology, we can judge the feasibility of any possible measurement scheme for avian magnetoreception, and shed light on an intrinsic relevance between the singlet yield and a concrete measurement scheme of our approach. The present work allows us to understand many things about avian magnetoreception from a fully new perspective of quantum metrology, and provide a new route to establish a direct connection between quantum information and many other biological functions.

arXiv:1612.00557•Dec 2, 2016•0 citations

The rationality of radical pair mechanism in real biological systems

Xiaoyu Chen, Haibin Liu, Jianming Cai

The radical pair mechanism (RPM) in the chemical magnetic compass model is considered to be one of the most promising candidates for the avian magnetic navigation, and quantum needle phenomenon further boosts the navigation precision to a new high level. It is well known that there are also a variety of methods in the field of magnetic field sensing in laboratory, e.g. Ramsey protocol of NV centers in diamond. Here, we compare the RPM model and Ramsey-like model under laboratory conditions and under in vivo conditions respectively. The results are both surprising and reasonable. Under laboratory conditions, if we have precise control over time and a reasonably accurate prior knowledge of the magnetic field direction, the Ramsey-like model will outperform the RPM model. However, when such information is unavailable, as under in vivo conditions, the RPM model stands out. The RPM model achieves greater practicality at the cost of reduced accuracy.

physics.bio-phCross-listedarXiv:2512.05974•Nov 26, 2025

Quantum limits for the magnetic sensitivity of a chemical compass

Jianming Cai, Filippo Caruso, Martin Bodo Plenio

The chemical compass model, based on radical pair reactions, is an idea to explain avian magnetoreception. At present, to the best of our knowledge, questions concerning the key ingredients responsible for the high sensitivity of a chemical compass and the possible role of quantum coherence and decoherence remain unsolved. Here, we investigate the optimized hyperfine coupling for a chemical compass in order to achieve the best magnetic field sensitivity. We show that its magnetic sensitivity limit can be further extended by simple quantum control and may benefit from additional decoherence. With this, we clearly demonstrate how quantum coherence can be exploited in the functioning of a chemical compass. The present results also provide routes toward the design of a biomimetic weak magnetic field sensor.

arXiv:1108.4304•Physical Review A•Apr 11, 2012•64 citations

Quantifying Magnetic Sensitivity of Radical Pair Based Compass by Quantum Fisher Information

Li-Sha Guo, Bao-Ming Xu, Jian Zou +1 more

The radical pair (RP) based compass is considered as one of the principal models of avian magnetoreception. Different from the conventional approach where the sensitivity of RP based compass is described by the singlet yield, we introduce the quantum Fisher information (QFI), which represents the maximum information about the magnetic field's direction extracted from the RP state, to quantify the sensitivity of RP based compass. The consistency between our results and experimental observations suggests that the QFI may serve as a measure to describe the sensitivity of RP based compass. Besides, within the framework of quantum metrology, we give two specific possible measurement schemes and find that the conventional singlet yield is corresponding to the measurement of total angular momentum. Moreover, we show that the measurement of fluctuation of the total magnetic moment is much more accurate than the singlet yield measurement, and is close to the optimal measurement scheme. Finally, the effects of entanglement and decoherence are also discussed in the spirit of our approach.

Scientific Reports•Jul 13, 2017•10 citations

Quantum Control and Entanglement in a Chemical Compass

Jianming Cai, Gian Giacomo Guerreschi, Hans J. Briegel

The radical-pair mechanism is one of the two main hypotheses to explain the navigability of animals in weak magnetic fields, enabling, e.g., birds to see Earth's magnetic field. It also plays an essential role in spin chemistry. Here, we show how quantum control can be used to either enhance or reduce the performance of such a chemical compass, providing a new route to further study the radical-pair mechanism and its applications. We study the role of radical-pair entanglement in this mechanism, and demonstrate its intriguing connections with the magnetic-field sensitivity of the compass. Beyond their immediate application to the radical-pair mechanism, these results also demonstrate how state-of-the-art quantum technologies could potentially be used to probe and control biological functions.

arXiv:0906.2383•Physical Review Letters•Jun 4, 2010•184 citations
Magnetic measurement can be performed by various sensors, such as SQUID and Giant Magnetoresistance. This device can achieve high accuracy while losing efficiency and convenience. The model of biological magnetic sensing in avian proposes a radical pair response to the external field on the FLY results in regulating animal behaviour. Inspired by the radical pair system found in biological system, the effect of intra-radical coupling and the initial condition is studied in this simplified radical pair model as the quantum advantage results from entanglement and superposition are investigated in metrology. To identify the sensing benefit from the cooperation between the radical pairs, the inter-radical coupling is considered. We find the intra-radical coupling determines the sensing regime while the coupled radical pair system enables a new sensing scheme that provides a more general and flexible way for magnetic sensing in a broader range through a easier manipulation to the system.
The radical pair mechanism is one of the two main hypotheses to explain the navigability of animals in weak magnetic fields, enabling e.g. birds to see the Earth's magnetic field. It also plays an essential role in the field of spin chemistry. Here, we show how quantum control can be used to either enhance or reduce the performance of such a chemical compass, providing a new route to further study the radical pair mechanism and its applications. We study the role of quantum entanglement in this mechanism, and demonstrate intriguing connections between radical-pair entanglement and the magnetic field sensitivity of the compass. Beyond their immediate application to the radical pair mechanism, these results also demonstrate how state-of-the-art quantum technologies could potentially be used to probe and control biological functions.
The radical pair (RP) mechanism, which describes the quantum dynamics of a spatially separated electron pair, is considered as one of the principal models of avian magnetoreception. Different from the conventional phenomenological approach where the sensitivity of avian magnetoreception is characterized by the singlet yield ΦSΦ_{S}ΦS​, we introduce the quantum Fisher information (QFI), which represents the maximum information about the magnetic field's direction extracted from the RP state, to give a precise measure of sensitivity of avian compass essentially. The consistency between our results and experimental observations suggests that QFI plays a decisive role in avian magnetoreception. Besides, within the framework of quantum metrology, we can judge the feasibility of any possible measurement scheme for avian magnetoreception, and shed light on an intrinsic relevance between the singlet yield and a concrete measurement scheme of our approach. The present work allows us to understand many things about avian magnetoreception from a fully new perspective of quantum metrology, and provide a new route to establish a direct connection between quantum information and many other biological functions.
The radical pair mechanism (RPM) in the chemical magnetic compass model is considered to be one of the most promising candidates for the avian magnetic navigation, and quantum needle phenomenon further boosts the navigation precision to a new high level. It is well known that there are also a variety of methods in the field of magnetic field sensing in laboratory, e.g. Ramsey protocol of NV centers in diamond. Here, we compare the RPM model and Ramsey-like model under laboratory conditions and under in vivo conditions respectively. The results are both surprising and reasonable. Under laboratory conditions, if we have precise control over time and a reasonably accurate prior knowledge of the magnetic field direction, the Ramsey-like model will outperform the RPM model. However, when such information is unavailable, as under in vivo conditions, the RPM model stands out. The RPM model achieves greater practicality at the cost of reduced accuracy.
The chemical compass model, based on radical pair reactions, is an idea to explain avian magnetoreception. At present, to the best of our knowledge, questions concerning the key ingredients responsible for the high sensitivity of a chemical compass and the possible role of quantum coherence and decoherence remain unsolved. Here, we investigate the optimized hyperfine coupling for a chemical compass in order to achieve the best magnetic field sensitivity. We show that its magnetic sensitivity limit can be further extended by simple quantum control and may benefit from additional decoherence. With this, we clearly demonstrate how quantum coherence can be exploited in the functioning of a chemical compass. The present results also provide routes toward the design of a biomimetic weak magnetic field sensor.
The radical pair (RP) based compass is considered as one of the principal models of avian magnetoreception. Different from the conventional approach where the sensitivity of RP based compass is described by the singlet yield, we introduce the quantum Fisher information (QFI), which represents the maximum information about the magnetic field's direction extracted from the RP state, to quantify the sensitivity of RP based compass. The consistency between our results and experimental observations suggests that the QFI may serve as a measure to describe the sensitivity of RP based compass. Besides, within the framework of quantum metrology, we give two specific possible measurement schemes and find that the conventional singlet yield is corresponding to the measurement of total angular momentum. Moreover, we show that the measurement of fluctuation of the total magnetic moment is much more accurate than the singlet yield measurement, and is close to the optimal measurement scheme. Finally, the effects of entanglement and decoherence are also discussed in the spirit of our approach.
The radical-pair mechanism is one of the two main hypotheses to explain the navigability of animals in weak magnetic fields, enabling, e.g., birds to see Earth's magnetic field. It also plays an essential role in spin chemistry. Here, we show how quantum control can be used to either enhance or reduce the performance of such a chemical compass, providing a new route to further study the radical-pair mechanism and its applications. We study the role of radical-pair entanglement in this mechanism, and demonstrate its intriguing connections with the magnetic-field sensitivity of the compass. Beyond their immediate application to the radical-pair mechanism, these results also demonstrate how state-of-the-art quantum technologies could potentially be used to probe and control biological functions.