Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2202.09746

Ultrasensitive refractive index sensor with rotatory biased weak measurement

Chongqi Zhou, Yang Xu, Xiaonan Zhang, Zhangyan Li, Tian Guan, Yonghong He, Ji, Yanhong

Published Feb 20, 2022• 0 citations
arXivHTMLPDF

Abstract

A modified weak measurement scheme, rotatory biased weak measurement, is proposed to significantly improve the sensitivity and resolution of the refractive index sensor on a total reflection structure. This method introduces an additional phase in the post-selected procedure and generates an extinction point in the spectrum distribution. The biased post-selection makes smaller coupling strength available, which leads to an enhancement of phase sensitivity and refractive index sensitivity. In rotatory biased weak measurement, we achieve an enhanced refractive index sensitivity of 13605 nm/RIU compared to 1644 nm/RIU in standard weak measurement. The performance of sensors with different sensitivity is analyzed, and we find the optimal refractive index resolution of sensors increases with sensitivity. In this work, we demonstrate an optimal refractive index resolution of $4\times10^{-7}$ RIU on a total reflection structure. The rabbit anti-mouse IgG and mouse IgG binding reaction experiments demonstrate that our system has a high response to the concentration of IgG in a wide range and the limit of detection is 15 ng/mL. The improvements in this work are helpful to the optimizations of other optical sensors with weak measurement.

DOI
10.48550/arxiv.2202.09746

Related papers

Improving the precision of optical metrology by detecting fewer photons with biased weak measurement

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.

Light Science & Applications•May 17, 2021•43 citations

Improving the Precision of Optical Metrology by Detecting Fewer Photons

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to circumvent detector saturation effect with low-cost apparatuses.

arXiv:2103.12373•Mar 23, 2021•0 citations

Enhancing sensitivity of ultrasmall rotation velocity measurements with biased quantum weak measurement

Guangjun Wang, Xue-Ying Duan, Jing-Hui Huang +1 more

Recently, biased quantum weak measurement has shown higher precision than both conventional measurement and standard quantum weak measurement in optical metrology. In this work, a scheme of detecting the ultrasmall rotation velocity in Sagnac's interferometer with biased quantum weak measurement is proposed. In biased quantum weak measurement, additional progress of pre-coupling is introduced in standard quantum weak measurement to enhance the sensitivity for the estimated parameter, and the cost of the reduction of photons in the post-selection by pre-coupling may not impact the measurement because eliminating the saturation effect of the detector response. In addition, our numerical results show that the scheme with biased quantum weak measurement can obtain a higher sensitivity for rotation velocity measurement than the scheme with standard quantum weak measurement.

Chinese Control Conference (CCC)•Jul 25, 2022•0 citations

Trough-Shift Pointer for Weak Measurement with Large Range and High Spectral Resolution

Wenzhao Huang, Zifu Su, Weiqian Zhao +3 more

Weak measurement enables the amplification of weak physical effects via post-selection and has become an important tool in precision optical metrology; however, conventional schemes based on mean-pointer shifts suffer from response saturation, limited linear range, and stringent stability requirements. Here, we propose and experimentally demonstrate a weak-measurement scheme based on spectral-interference trough shifts, where the zero-intensity points of the post-selected spectrum act as the measurement pointer, establishing an analytical mapping between the trough displacement and the target phase or time delay. Theoretical analysis shows that, under detector resolution limits, the measurement resolution depends solely on the frequency of extinction point and is independent of weak-value singular amplification or bias-phase modulation, thereby maintaining high sensitivity while avoiding pointer saturation. Experiments demonstrate that the trough-shift scheme achieves significantly better agreement between measured and theoretical sensitivities than biased weak measurement and provides a stable linear response without additional bias-compensation structures, reaching a minimum resolvable phase variation at the 10−7 level. Moreover, the approach intrinsically supports multi-period traceable measurements and exhibits strong robustness against intensity fluctuations and spectral distortions, offering a promising route toward high-sensitivity, large-dynamic-range, and stable weak measurement-based optical sensing.

Photonics•Mar 30, 2026•0 citations

Measuring angular rotation via the rotatory dispersion effect

Chongqi Zhou, Suyi Zhong, Kaijie Ma +3 more

We propose a scheme for an ultrasensitive weak measurement system with an ultrasmall rotatory dispersion effect to measure angular rotation. Estimation of angular rotation is obtained by the shift of the center wavelength. In our scheme, we obtain a continuously adjustable coupling strength and show that our system provides a 13 times higher sensitivity of 38 840 nm/rad compared with previous work. Here we demonstrate that our scheme may offer an optimal weak value ${A}_{w}$ in practice and outperforms conventional measurements in the presence of technical noise. The precision achieved by optimized weak value amplification (WVA) is about three times higher than that of a polarimeter. Our work extends the working regime of WVA. Its simplicity and robustness clear the way for widespread use of WVA involving measurements with commercial cameras and small signals.

Physical Review A•Dec 22, 2020•12 citations

Optical weak measurement for the precise thickness determination of an ultra-thin film

Jing-Ru Zhao, Zhenjie Wu, Guiqiang Wang +3 more

A total internal reflection system based on the weak value amplification principle is set up for the precise measurement of the thickness of an ultra-thin film. In this system, the film thickness is derived from the change of the double-peak pointer caused by the effective refractive index of the film, which is correlated to its thickness. The sensitivity and resolution of this system reached 2727.21 nm/RIU and 7.2 × 10 − 6 R I U , respectively, determined by using a sodium chloride solution with a refractive index of 1.331911. The growth process of TA/Fe(III) assembled films with thicknesses in the few nanometers range is monitored using the as-set-up system, and the experimental results are consistent with a theoretical calculation based on the Maxwell Garnett effective medium. Additionally, we theoretically calculated the detection limit for the thickness measurement of the film as 22 pm. We clearly provide a potential method for the precise measurement of the thickness of an ultra-thin film.

Applied Optics•Nov 3, 2022•4 citations
A modified weak measurement scheme, rotatory biased weak measurement, is proposed to significantly improve the sensitivity and resolution of the refractive index sensor on a total reflection structure. This method introduces an additional phase in the post-selected procedure and generates an extinction point in the spectrum distribution. The biased post-selection makes smaller coupling strength available, which leads to an enhancement of phase sensitivity and refractive index sensitivity. In rotatory biased weak measurement, we achieve an enhanced refractive index sensitivity of 13605 nm/RIU compared to 1644 nm/RIU in standard weak measurement. The performance of sensors with different sensitivity is analyzed, and we find the optimal refractive index resolution of sensors increases with sensitivity. In this work, we demonstrate an optimal refractive index resolution of 4×10−74\times10^{-7}4×10−7 RIU on a total reflection structure. The rabbit anti-mouse IgG and mouse IgG binding reaction experiments demonstrate that our system has a high response to the concentration of IgG in a wide range and the limit of detection is 15 ng/mL. The improvements in this work are helpful to the optimizations of other optical sensors with weak measurement.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to circumvent detector saturation effect with low-cost apparatuses.
Recently, biased quantum weak measurement has shown higher precision than both conventional measurement and standard quantum weak measurement in optical metrology. In this work, a scheme of detecting the ultrasmall rotation velocity in Sagnac's interferometer with biased quantum weak measurement is proposed. In biased quantum weak measurement, additional progress of pre-coupling is introduced in standard quantum weak measurement to enhance the sensitivity for the estimated parameter, and the cost of the reduction of photons in the post-selection by pre-coupling may not impact the measurement because eliminating the saturation effect of the detector response. In addition, our numerical results show that the scheme with biased quantum weak measurement can obtain a higher sensitivity for rotation velocity measurement than the scheme with standard quantum weak measurement.
Weak measurement enables the amplification of weak physical effects via post-selection and has become an important tool in precision optical metrology; however, conventional schemes based on mean-pointer shifts suffer from response saturation, limited linear range, and stringent stability requirements. Here, we propose and experimentally demonstrate a weak-measurement scheme based on spectral-interference trough shifts, where the zero-intensity points of the post-selected spectrum act as the measurement pointer, establishing an analytical mapping between the trough displacement and the target phase or time delay. Theoretical analysis shows that, under detector resolution limits, the measurement resolution depends solely on the frequency of extinction point and is independent of weak-value singular amplification or bias-phase modulation, thereby maintaining high sensitivity while avoiding pointer saturation. Experiments demonstrate that the trough-shift scheme achieves significantly better agreement between measured and theoretical sensitivities than biased weak measurement and provides a stable linear response without additional bias-compensation structures, reaching a minimum resolvable phase variation at the 10−7 level. Moreover, the approach intrinsically supports multi-period traceable measurements and exhibits strong robustness against intensity fluctuations and spectral distortions, offering a promising route toward high-sensitivity, large-dynamic-range, and stable weak measurement-based optical sensing.
We propose a scheme for an ultrasensitive weak measurement system with an ultrasmall rotatory dispersion effect to measure angular rotation. Estimation of angular rotation is obtained by the shift of the center wavelength. In our scheme, we obtain a continuously adjustable coupling strength and show that our system provides a 13 times higher sensitivity of 38 840 nm/rad compared with previous work. Here we demonstrate that our scheme may offer an optimal weak value Aw{A}_{w}Aw​ in practice and outperforms conventional measurements in the presence of technical noise. The precision achieved by optimized weak value amplification (WVA) is about three times higher than that of a polarimeter. Our work extends the working regime of WVA. Its simplicity and robustness clear the way for widespread use of WVA involving measurements with commercial cameras and small signals.
A total internal reflection system based on the weak value amplification principle is set up for the precise measurement of the thickness of an ultra-thin film. In this system, the film thickness is derived from the change of the double-peak pointer caused by the effective refractive index of the film, which is correlated to its thickness. The sensitivity and resolution of this system reached 2727.21 nm/RIU and 7.2 × 10 − 6 R I U , respectively, determined by using a sodium chloride solution with a refractive index of 1.331911. The growth process of TA/Fe(III) assembled films with thicknesses in the few nanometers range is monitored using the as-set-up system, and the experimental results are consistent with a theoretical calculation based on the Maxwell Garnett effective medium. Additionally, we theoretically calculated the detection limit for the thickness measurement of the film as 22 pm. We clearly provide a potential method for the precise measurement of the thickness of an ultra-thin film.