Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2112.02568 · Physical Review Research

Swap-test interferometry with biased qubit noise

Ondřej Černotík, Iivari Pietikäinen, Shruti Puri, S. M. Girvin, Radim Filip

Published Jul 17, 2024• 3 citations
arXivHTMLPDF

Abstract

The Mach-Zehnder interferometer is a powerful device for detecting small phase shifts between two light beams. Simple input states, such as coherent states or single photons, can reach the standard quantum limit of phase estimation, while more complex states can be used to reach Heisenberg scaling; the latter, however, require challenging preparation and measurement strategies. The quest for highly sensitive phase estimation therefore calls for interferometers with nonlinear devices which would make the preparation of these complex states more efficient. Here, we show that the Heisenberg scaling can be recovered with simple input states (including Fock and coherent states) when the linear mirrors in the interferometer are replaced with controlled-swap gates and measurements on auxiliary qubits. These swap tests project the input Fock and coherent states onto NOON and entangled coherent states, respectively, and allow optimal or near-optimal measurements, leading to improved sensitivity to small phase shifts in one of the interferometer arms. We analyze auxiliary qubit errors in detail, showing that biasing the qubit towards phase flips offers a great advantage, and perform thorough numerical simulations of a possible implementation in circuit quantum electrodynamics with an auxiliary Kerr-cat qubit. Our results thus present a viable approach to phase estimation approaching Heisenberg-limited sensitivity and demonstrate potential advantages of using biased-noise qubits in quantum metrology. Published by the American Physical Society 2024

DOI
10.1103/physrevresearch.6.033074

Related papers

Phase sensitivity of a quantum Mach-Zehnder interferometer for a coherent state input

Taesoo Kim, Heonoh Kim

The phase sensitivity of a Mach-Zehnder interferometer utilizing quantum entanglement is analyzed for a coherent state input. The results show that the Heisenberg limit in the measurement of the phase shift is obtainable with a coherent input. Moreover, the scheme turns out to be immune to the imperfect detector efficiencies. This suggests another promising route for implementing sub-shot-noise measurement schemes.

Journal of the Optical Society of America B•Mar 12, 2009•5 citations

Phase Estimation in Linear and Nonlinear Interferometers

Sushovit Adhikari

Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.

Civil War Book Review•Feb 22, 2019•0 citations

Quantum metrology for simultaneously estimating the linear and nonlinear phase shifts

Jing Cheng

Quantum metrology allows the enhanced precision on estimating phase shifts in an optical interferometer to reach the $\ensuremath{\propto}1/N$ scaling of precision ($N$ is the mean photon number of the light field). But when $N$ is very large, the nonlinear optical effects may be nonnegligible. Here we investigate theoretically the quantum uncertainty bounds for simultaneously detecting the linear and nonlinear phase shifts. Focusing our attentions only on the linear and the nonlinear Kerr phase shifts, we find the NOON states can not be used to measure the two phase parameters. Using the entangled coherent states, the estimation precision is limited by the $1/{N}^{1/2}$ ($1/{N}^{3/2}$) scaling for the linear (nonlinear) phase. To increase the precisions and beat the standard quantum limit, we show that the entangled Schr\"odinger-cat states can be used to reach the $1/N$ scaling for the linear phase and $1/{N}^{2}$ scaling for the nonlinear phase.

Physical Review A•Dec 29, 2014•24 citations

Improved linear and Kerr nonlinear phase estimation via photon addition operations

Zekun Zhao, Qingqian Kang, Shoukang Chang +4 more

Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.

arXiv:2505.16123•Communications in Theoretical Physics•Feb 4, 2026•0 citations

Nonlinear interferometer as a resource for maximally entangled photonic states: Application to interferometry

Christopher C. Gerry, Adil Benmoussa, Richard A. Campos

Nonlinear interferometers are Mach-Zehnder interferometers with Kerr media in either one or both arms. We refer to these devices, respectively, as the asymmetric and symmetric nonlinear interferometers. In the asymmetric case, with one input mode in the vacuum, it is possible to generate maximally entangled photonic states or superpositions of such states. We consider the device as a resource of entangled states for applications to Heisenberg-limited interferometry. Interferometry with the maximally entangled states cannot be performed by simply subtracting the output photocounts as in standard interferometry. Instead, one must perform parity measurements on only one of the output beams. We show that the symmetric nonlinear interferometer, with one input mode in the vacuum, may be used to perform such parity measurements. The same device is shown to produce, with an input coherent state and upon projective measurements, even or odd coherent states, examples of the Schr\"odinger-cat states.

Physical Review A•Jul 11, 2002•106 citations

Nonlinear phase estimation enhanced by an actively correlated Mach-Zehnder interferometer

Gao-Feng Jiao, Keye Zhang, L. Q. Chen +2 more

A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.

arXiv:2009.08059•Physical Review A•Sep 21, 2020•27 citations
The Mach-Zehnder interferometer is a powerful device for detecting small phase shifts between two light beams. Simple input states, such as coherent states or single photons, can reach the standard quantum limit of phase estimation, while more complex states can be used to reach Heisenberg scaling; the latter, however, require challenging preparation and measurement strategies. The quest for highly sensitive phase estimation therefore calls for interferometers with nonlinear devices which would make the preparation of these complex states more efficient. Here, we show that the Heisenberg scaling can be recovered with simple input states (including Fock and coherent states) when the linear mirrors in the interferometer are replaced with controlled-swap gates and measurements on auxiliary qubits. These swap tests project the input Fock and coherent states onto NOON and entangled coherent states, respectively, and allow optimal or near-optimal measurements, leading to improved sensitivity to small phase shifts in one of the interferometer arms. We analyze auxiliary qubit errors in detail, showing that biasing the qubit towards phase flips offers a great advantage, and perform thorough numerical simulations of a possible implementation in circuit quantum electrodynamics with an auxiliary Kerr-cat qubit. Our results thus present a viable approach to phase estimation approaching Heisenberg-limited sensitivity and demonstrate potential advantages of using biased-noise qubits in quantum metrology. Published by the American Physical Society 2024
Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.
Quantum metrology allows the enhanced precision on estimating phase shifts in an optical interferometer to reach the $\ensuremath{\propto}1/N$ scaling of precision (NNN is the mean photon number of the light field). But when NNN is very large, the nonlinear optical effects may be nonnegligible. Here we investigate theoretically the quantum uncertainty bounds for simultaneously detecting the linear and nonlinear phase shifts. Focusing our attentions only on the linear and the nonlinear Kerr phase shifts, we find the NOON states can not be used to measure the two phase parameters. Using the entangled coherent states, the estimation precision is limited by the 1/N1/21/{N}^{1/2}1/N1/2 (1/N3/21/{N}^{3/2}1/N3/2) scaling for the linear (nonlinear) phase. To increase the precisions and beat the standard quantum limit, we show that the entangled Schr\"odinger-cat states can be used to reach the 1/N1/N1/N scaling for the linear phase and 1/N21/{N}^{2}1/N2 scaling for the nonlinear phase.
Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.
Nonlinear interferometers are Mach-Zehnder interferometers with Kerr media in either one or both arms. We refer to these devices, respectively, as the asymmetric and symmetric nonlinear interferometers. In the asymmetric case, with one input mode in the vacuum, it is possible to generate maximally entangled photonic states or superpositions of such states. We consider the device as a resource of entangled states for applications to Heisenberg-limited interferometry. Interferometry with the maximally entangled states cannot be performed by simply subtracting the output photocounts as in standard interferometry. Instead, one must perform parity measurements on only one of the output beams. We show that the symmetric nonlinear interferometer, with one input mode in the vacuum, may be used to perform such parity measurements. The same device is shown to produce, with an input coherent state and upon projective measurements, even or odd coherent states, examples of the Schr\"odinger-cat states.
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.