Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. In simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.
Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. In simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.
Bose-Einstein condensates are coherent matter waves, produced by cooling gaseous atomic clouds to ultra-low temperatures. For applications in atom interferometry and precision measurements, Bose-condensed sources present an intriguing alternative to thermal atoms. Although the current sensitivity achievable with interferometers using coherent atoms is not comparable to thermal beam machines (mainly due to the lower flux), there are promising ways to utilise the potential of Bose-condensed sources for atom interferometry. Among those is the low momentum width of Bose-Einstein condensates, which can generally be well controlled and is advantageous for increased interferometric sensitivities by implementing large momentum transfer beam splitters. As part of this thesis, experimental and theoretical investigations are presented to investigate the potential of Bose-Einstein condensates for such applications. We shall present the quantum projection noise limited performance of a Ramsey interferometer operating on the atomic clock transition of a freely expanding cloud of Bose-condensed rubidium 87 atoms. The results include Ramsey fringes of high visibility, not measurably affected by atomic interaction-induced dephasing effects. The achievement and detection of the quantum projection noise limit rely critically on the precision and accuracy of both the imaging setup and the coupling scheme in the interferometric beam splitters. The stabilisation of the beam splitters via an optical Sagnac interferometer is the basis for the quantum projection noise limited performance of the interferometer presented. For an increase of bandwidth and flux in atom interferometric measurements, it is advantageous to use a continuous atomic beam. A truly continuous coherent atom source has not been realised to date, and we present results on a pumping mechanism in this thesis, as a decisive step towards a continuous atom laser. By the investigation of different momentum resonances, we find that the pumping scheme relies on a Raman superradiance-like process. Finally, the thesis demonstrates two interaction measurements in rubidium. The strong mean field interactions due to the high densities in Bose-Einstein condensates are used to probe the potential of a rubidium 87 condensate with an atom laser. The measurement allows a determination of the scattering length between the two atomic states involved. In addition to this two-body scattering scheme, we present a measurement of three-body loss coefficients, extracted from loss curves in rubidium 85 Bose-Einstein condensates. The measurement provides new upper bounds on the three-body loss coefficients at the scattering lengths considered.
In a recent experiment (Wang et al., e-print cond-mat/0407689), it was observed that a sequence of two standing-wave square pulses can split a Bose-Einstein Condensate at rest into $\ifmmode\pm\else\textpm\fi{}2\ensuremath{\hbar}\mathbf{k}$ diffraction orders with almost 100% efficiency. By truncating the Raman-Nath equations to a two-state model, we provide an intuitive picture that explains this double-square-pulse beam-splitter scheme. We further show it is possible to optimize a standing-wave multiple-square-pulse sequence to efficiently diffract an atom at rest to a symmetric superposition of $\ifmmode\pm\else\textpm\fi{}2n\ensuremath{\hbar}\mathbf{k}$ diffraction orders with n>1. The approach is considered to be qualitatively different from the traditional light-pulse schemes in the Bragg or the Raman-Nath region, and can be extended to more complex atomic optical elements that produce various tailored output momentum states from a cold atom source.
This thesis contributes to the debate over the viability of using Bose-condensed sources to improve the sensitivity of atom interferometers. Specifically, we present theoretical investigations into (1) the effect of source momentum width on large momentum transfer (LMT) atom interferometry with Bragg pulses, and (2) the prospect of stabilising a high flux, narrow linewidth, continuously pumped atom laser via measurement-based feedback control of the BEC that forms the lasing mode of the atom laser. To begin, this thesis considers the effect of the atomic source's momentum width on the phase sensitivity of Bragg pulse atom interferometers in the Mach-Zehnder configuration. We show that an atomic cloud's momentum width places a fundamental upper bound on the maximum transfer efficiency of a Bragg mirror pulse, and furthermore limits the phase sensitivity of a Bragg pulse atom interferometer. We quantify these momentum width effects and precisely compute how mirror efficiencies and interferometer phase sensitivities vary as functions of Bragg order and source type. In particular, we show that narrow momentum width Bose-condensed sources give comparable sensitivities to broad momentum width thermal sources, even after incorporating the lower atom flux of Bose-condensed sources. Coupled with other favourable properties of Bose-condensed sources, such as their high tolerance to classical noise due to optical wavefront aberrations and the Coriolis effect, this suggests that LMT Bragg atom interferometry with Bose-condensed sources should yield improved sensitivities over current inertial sensors. Furthermore, our results and methodology allow for the efficient optimisation of Bragg pulses, which will help in the design of LMT Bragg mirrors and beamsplitters for atom-interferometer-based inertial sensors, irrespective of source type. In the second part of this thesis, we investigate the prospect of measurement-based feedback control of a BEC, with the aim of reducing density fluctuations by cooling the condensate to a stable spatial mode. Firstly, we consider the effects of experimental imperfections on the estimation-based feedback control of a weakly-interacting BEC undergoing continuous position measurement. These limitations violate the assumption that the estimator (i.e., filter) accurately models the underlying system, thus requiring a separate analysis of the system and filter dynamics. We show that the control scheme is robust to detector inefficiency, time delay, technical noise and miscalibrated parameters. These results imply that reasonable experimental imperfections do not limit the feasibility of cooling a BEC by continuous measurement and feedback. Secondly, we designed a feedback-control scheme for a trapped condensate, with interatomic interactions of any strength, based on a phase-contrast imaging setup. We derive the filtering equation for the system, and show that it gives a continuous measurement of the condensate's density. A semiclassical analysis of this control scheme shows that feedback-cooling of an interacting BEC is also possible, and that the interatomic interactions actually increase the effectiveness of the control. Therefore, measurement-based feedback control can stabilise the spatial mode of a BEC, which is a requirement for the high flux, narrow linewidth, continuously pumped atom laser sources that could potentially give inertial measurement sensitivities orders of magnitude beyond current state-of-the-art devices.
Atomic interferometry is very useful in fundamental studies of coherence, decoherence and phase shifts and for practical precision measurements, with the example of gravimeters, gyroscopes, and gradiometers (Cronin et al., 2009). Bose-Einstein Condensate (BEC) based atomic interferometry provides high contrasts, long integration times and the possible use of small devices (Baumgartner et al., 2010; Sapiro et al., 2009a; Torii et al., 2000). In such atomic interferometry, coherent momentum manipulation is very effective for splitting and recombining the condensate (Deng et al., 1999; Kozuma, Deng et al., 1999; Ovchinnikov et al., 1999), for realizing the interference. In some precision measurements, the accumulated phase is positively correlated to the atomic velocity, so that the larger the atomic momentum is, the more precise the measurements can be if the measuring time is unchanged.
Atom interferometry allows for new precision limits in measurement and a key component of it is the beam-splitter. In this thesis we look at the properties of an all optical beam-splitter, which is created by the overlap of two Gaussian laser beams,which also function as waveguides for the Bose-Einstein condensate. For this mainly the split step Fourier method is used to model the propagation of a low density Bose-Einstein condensate of atoms. The two main areas of interest are the splitting and recombination properties. \nThe splitting is studied both in two and one dimensions. For the one-dimensional case both standing and propagating waves are used to find the ideal splitting conditions of a balanced splitting and transmission. The result of these methods are in general agreement with the exception that for the propagating wave some of the atoms can become localised inside the beam-splitter. For the propagation it was found that the splitting is not perfectly coherent as the outputs are slightly deformed. However, when looking at the two-dimensional case we see that the splitting is not even close to being coherent. This is because the beam-splitter excites the incoming wave into higher transverse modes of the waveguides. To compensate for this the depth of the waveguides was lowered and the width narrowed to reduce the potential kinetic energy that the atoms could acquire and to increase the separation between the eigenstates to lower the probability of excitation into higher modes, respectively. Nonetheless, these investigations improved the splitting balance but it is still not coherent. Another method investigated was the introduction of a third laser which acts as a filling to reduce the depth of the potential well where the lasers generate the beam-splitter. This approach does not improve the splitting. \nHence instead of recombining single mode waves we used a multimode approach. For this we found that the mirror position is crucial for certain parameters as the longitudinal momentum is not necessarily the same in the reflection and transmission waveguide. Our investigations have generated interference fringes in this model \nsystem with a fractional height up to 33%.
Matter-wave interferometers show great a potential for improving inertial sensing. The absence of drifts recommends them for a variety of applications in geodesy, navigation, or fundamental physics. Here, ultracold atomic ensembles, featuring a velocity distribution well below the photon recoil velocity, open up new perspectives. In contrast to standard laser cooling methods, they allow to reach better beam-splitting efficiencies and, hence, a higher contrast as well as to reduce systematic uncertainties and biases. Presently, Bose-Einstein condensates (BECs) provide the means to achieve the lowest expansion energies of few picokelvin. Indeed, the momentum distribution of a BEC can be further narrowed after reaching the regime of ballistic expansion, where all mean field energy is converted to kinetic energy, by the application of the delta-kick collimation technique. With such ensembles, Bragg processes can be driven with an efficiency of above 95% as well as Bloch oscillations performed without large atomic losses or dephasing. Both enable efficient large momentum transfer in interferometers to enhance their sensitivity for inertial effects. In a so-called twin-lattice atom interferometers more than thousand photon recoils are used to form compact but sensitive atom interferometers. These methods not only bring in reach extremely accurate gravimeters and accelerometers but also gyroscopes. Like the Sagnac effect in ring laser or fiber gyroscopes, the sensitivity of atom interferometers to rotations increases with the space-time area enclosed by the interferometer. In the case of light interferometers, the latter can be enlarged by forming multiple fiber loops. However, the equivalent for matter-wave interferometers remains an experimental challenge. An atom interferometer with scalable area may be formed in a twin lattice combined with a relaunch mechanism to obtain multi loops as well. Due to this scalability, it offers the perspective of reaching unprecedented sensitivities for rotations in comparably compact sensor head setups. Moreover, atom-chip technologies offer the possibility to generate a BEC and perform delta-kick collimation in a fast and reliable away, paving the way for field-deployable miniaturized atomic devices. Last but not least, the extremely low expansion energies of BECs open up to extend the time atoms spend in the interferometer to tens of seconds. This brings in reach unprecedented sensitivities in space-borne applications such as satellite geodesy.