arXiv:2110.13273 · AVS Quantum Science

Testing the universality of free fall using correlated 39K–87Rb atom interferometers

B. Barrett, G. Condon, Laure Chichet, Laura Antoni‐Micollier, Romain Arguel, Martin Rabault, Célia Pelluet, Vincent Jarlaud, Arnaud Landragin, Philippe Bouyer, Baptiste Battelier

Published Feb 9, 2022• 31 citations
arXivHTMLPDF

Abstract

We demonstrate how simultaneously operated 39K–87Rb interferometers exhibiting a high level of correlation can be used to make competitive tests of the university of free fall. This work provides an overview of our experimental apparatus and data analysis procedure, including a detailed study of systematic effects. With a total interrogation time of 2T=40 ms in a compact apparatus, we reach a statistical uncertainty on the measurement of the Eötvös parameter of 7.8×10−8 after 2.4×104 s of integration. The main limitations of our measurements arise from a combination of wavefront aberrations, the quadratic Zeeman effect in 39K, parasitic interferometers in 87Rb, and the velocity sensitivity of our detection system. These systematic errors limit the accuracy of our measurement to η=0.9(1.6)×10−6. We discuss prospects for improvements using ultracold atoms at extended interrogation times.

DOI
10.1116/5.0076502

Related papers

Quantum test of the Universality of Free Fall using rubidium and potassium

Henning Albers, Alexander Herbst, Logan L. Richardson +11 more

Abstract We report on an improved test of the Universality of Free Fall using a rubidium-potassium dual-species matter wave interferometer. We describe our apparatus and detail challenges and solutions relevant when operating a potassium interferometer, as well as systematic effects affecting our measurement. Our determination of the Eötvös ratio yields ηRb,K = −1.9 × 10−7 with a combined standard uncertainty of ση = 3.2 × 10−7. Graphical abstract

arXiv:2003.00939•The European Physical Journal D•Jul 1, 2020•37 citations

Dual matter-wave inertial sensors in weightlessness

B. Barrett, Laura Antoni‐Micollier, Laure Chichet +4 more

Abstract Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the finite free-fall time of the atoms limits the precision achievable on Earth, while in space interrogation times of many seconds will lead to unprecedented sensitivity. Here we realize simultaneous 87Rb–39K interferometers capable of operating in the weightless environment produced during parabolic flight. Large vibration levels (10−2 g Hz−1/2), variations in acceleration (0–1.8 g) and rotation rates (5° s−1) onboard the aircraft present significant challenges. We demonstrate the capability of our correlated quantum system by measuring the Eötvös parameter with systematic-limited uncertainties of 1.1 × 10−3 and 3.0 × 10−4 during standard- and microgravity, respectively. This constitutes a fundamental test of the equivalence principle using quantum sensors in a free-falling vehicle. Our results are applicable to inertial navigation, and can be extended to the trajectory of a satellite for future space missions.

arXiv:1609.03598•Nature Communications•Dec 12, 2016•214 citations

Inertial ultra-cold atom sensors in weightlessness

Baptiste Battelier, Philippe Bouyer, Arnaud Landragin +3 more

Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the best precision achievable on Earth is limited by the free-fall time of the atoms, and their full potential can only be realized in Space where interrogation times of many seconds will lead to unprecedented sensitivity. Various mission scenarios are presently being pursued, which plan to implement matter-waves inertial sensors to detect gravitational waves, to measure the Earth gravity field or to test fundamental physics such as the Equivalence Principle.We developed a cold atom sensor experiment adapted to microgravity platforms, especially the ZERO-G plane. To achieve a test of the Universality of Free Fall, we realize the first onboard operation of simultaneous ^{87}Rb - ^{39}K interferometers in the weightlessness environment produced during parabolic flight. The large vibration levels (10 ^{-2} g/Hz ^{1/2}), acceleration range and rotation rates (5 deg/s) during flight present significant technical challenges for atom interferometers. By hybridizing each atomic sensor with a common mechanical accelerometer, we achieve a sensitivity of 3.4 10 ^{-5} g per shot-more than 1600 times below the ambient vibration level onboard the aircraft. We demonstrate the capability of our dual-quantum sensor by measuring the Eötvös parameter with systematic-limited uncertainties of 3.0 10 ^{-4} during micro-gravity. This constitutes the first quantum test of the equivalence principle in a free falling vehicle. Our results can be extended to the trajectory of a satellite for future Space missions. We also achieved a simultaneous ^{87}Rb- ^{39}K interferometer on ground with a long term stability on the differential acceleration measurement around 5 10 ^{-8}g, limited by the fall of the atom clouds. To increase the interrogation time and the sensitivity, a ZERO-G simulator has been installed in our laboratory and allows our experiment to be in free fall during 500 ms every 12 seconds, to achieve highly repeatable measurements in microgravity. We expect to increase our short-term sensitivity by two orders of magnitude, and consequently reach a long-term measurement of the Eötvös parameter at the level of 10 ^{-11}.To benefit from the free fall of the experiment completely, it is necessary to produce atoms clouds with a reduced velocity dispersion. To reach this goal, we put ^{87}Rb atoms in an optical dipole trap supplied by a compact fiber laser compliant with onboard applications and decrease the optical power on a very controlled way to obtain evaporative cooling. Preliminary results of ultra-fast evaporative cooling (less than a few seconds) onboard the ZERO-G plane allowed us to reach a regime of temperature compliant with an interrogation time of the order of one second. This method and technology will be tested on the ZERO-G simulator as well.

•Jul 14, 2018•0 citations

Testing the Universality of Free Fall by Comparing the Atoms in Different Hyperfine States with Bragg Diffraction*

Ke Zhang, Min-Kang Zhou, Yuan Sheng Cheng +6 more

We perform a precision atom interferometry experiment to test the universality of free fall. Our experiment employs the Bragg atom interferometer with 87Rb atoms either in hyperfine state F = 1 , m F = 0 or F = 2 , m F = 0 , and the wave packets in these two states are diffracted by one pair of Bragg beams alternatively, which is helpful for suppressing common-mode systematic errors. We obtain an Eötvös ratio η 1 − 2 = 0.9 ± 2.7 × 10 − 10 , and set a new record on the precision with improvement of nearly 5 times. This measurement also provides constraint on the difference of the diagonal terms of the mass-energy operator.

Chinese Physics Letters•Apr 1, 2020•30 citations

Quantum tests of the universality of free fall

Dennis Schlippert

Quantum Tests of the Universality of Free FallIn the process of formulating a "theory of everything" that aims to provide a self-contained model of modern physics by unifying all four fundamental interactions, two theoretical frameworks have yielded important contributions: quantum mechanics, which can explain the nature of physics at the most microscopic length scales such as the origin of spectra of electrons bound in atomic systems, and Einstein's general relativity, that conveys our understanding of gravity over the largest distances across the universe.Although no theory of "quantum gravity", that is consistent over all energy scales, exists to date, certain modifications may enable a reconciliation of quantum mechanics and general relativity.These approaches allow for violations of the universality of free fall (UFF), that among Lorentz invariance and local position invariance constitute Einstein's equivalence principle.The UFF states that all bodies, located at the same space-time point, experience the same acceleration in a gravitational field independently of their composition.Because of its central role in modern physics the UFF has been tested extensively in many experiments, most of which utilized classical test masses.Quantum mechanical tests of the UFF differ from classical ones in various aspects such as the coherence length and spin polarization of the test masses.In this thesis, the first inertial-sensitive matter wave interferometer comparing the free fall of two different elements, 87 Rb and 39 K, was realized.This quantum test of the UFF yielded an Eötvös ratio 𝜂 Rb,K = (0.3 ± 5.4) × 10 -7 , and was limited by statistical uncertainty.In this work, an existing apparatus for rubidium interferometry was extended to the use of potassium and the first inertial-sensitive potassium matter wave interferometer with a resolution to gravitational acceleration of 𝜎 K = 3 × 10 -6 m/s 2 after 4096 s integration has been demonstrated.A description of the experiment including the technical realization and the techniques used is provided.Specifically, the challenges imposed by the use of potassium, which in comparison to rubidium has a smaller mass and lower hyperfine energy splitting, are examined.The thesis furthermore discusses an assessment of the systematic effects influencing the dual species measurement and presents future strategies to further improve the performance of the apparatus.As a preliminary result, it was possible to improve the potassium short-term sensitivity to gravitational acceleration to 𝜎 K = 2.1 × 10 -5 m/s 2 / √ Hz.The results of this thesis pave the way for exciting future experiments to be performed in large-scale apparatuses and in space.

Bulletin of the American Physical Society•Jan 1, 2014•3 citations

Improving the accuracy of atom interferometers with ultracold sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.

arXiv:1804.04909•New Journal of Physics•Nov 13, 2018•123 citations
We demonstrate how simultaneously operated 39K–87Rb interferometers exhibiting a high level of correlation can be used to make competitive tests of the university of free fall. This work provides an overview of our experimental apparatus and data analysis procedure, including a detailed study of systematic effects. With a total interrogation time of 2T=40 ms in a compact apparatus, we reach a statistical uncertainty on the measurement of the Eötvös parameter of 7.8×10−8 after 2.4×104 s of integration. The main limitations of our measurements arise from a combination of wavefront aberrations, the quadratic Zeeman effect in 39K, parasitic interferometers in 87Rb, and the velocity sensitivity of our detection system. These systematic errors limit the accuracy of our measurement to η=0.9(1.6)×10−6. We discuss prospects for improvements using ultracold atoms at extended interrogation times.
Abstract Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the finite free-fall time of the atoms limits the precision achievable on Earth, while in space interrogation times of many seconds will lead to unprecedented sensitivity. Here we realize simultaneous 87Rb–39K interferometers capable of operating in the weightless environment produced during parabolic flight. Large vibration levels (10−2 g Hz−1/2), variations in acceleration (0–1.8 g) and rotation rates (5° s−1) onboard the aircraft present significant challenges. We demonstrate the capability of our correlated quantum system by measuring the Eötvös parameter with systematic-limited uncertainties of 1.1 × 10−3 and 3.0 × 10−4 during standard- and microgravity, respectively. This constitutes a fundamental test of the equivalence principle using quantum sensors in a free-falling vehicle. Our results are applicable to inertial navigation, and can be extended to the trajectory of a satellite for future space missions.
Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the best precision achievable on Earth is limited by the free-fall time of the atoms, and their full potential can only be realized in Space where interrogation times of many seconds will lead to unprecedented sensitivity. Various mission scenarios are presently being pursued, which plan to implement matter-waves inertial sensors to detect gravitational waves, to measure the Earth gravity field or to test fundamental physics such as the Equivalence Principle.We developed a cold atom sensor experiment adapted to microgravity platforms, especially the ZERO-G plane. To achieve a test of the Universality of Free Fall, we realize the first onboard operation of simultaneous ^{87}Rb - ^{39}K interferometers in the weightlessness environment produced during parabolic flight. The large vibration levels (10 ^{-2} g/Hz ^{1/2}), acceleration range and rotation rates (5 deg/s) during flight present significant technical challenges for atom interferometers. By hybridizing each atomic sensor with a common mechanical accelerometer, we achieve a sensitivity of 3.4 10 ^{-5} g per shot-more than 1600 times below the ambient vibration level onboard the aircraft. We demonstrate the capability of our dual-quantum sensor by measuring the Eötvös parameter with systematic-limited uncertainties of 3.0 10 ^{-4} during micro-gravity. This constitutes the first quantum test of the equivalence principle in a free falling vehicle. Our results can be extended to the trajectory of a satellite for future Space missions. We also achieved a simultaneous ^{87}Rb- ^{39}K interferometer on ground with a long term stability on the differential acceleration measurement around 5 10 ^{-8}g, limited by the fall of the atom clouds. To increase the interrogation time and the sensitivity, a ZERO-G simulator has been installed in our laboratory and allows our experiment to be in free fall during 500 ms every 12 seconds, to achieve highly repeatable measurements in microgravity. We expect to increase our short-term sensitivity by two orders of magnitude, and consequently reach a long-term measurement of the Eötvös parameter at the level of 10 ^{-11}.To benefit from the free fall of the experiment completely, it is necessary to produce atoms clouds with a reduced velocity dispersion. To reach this goal, we put ^{87}Rb atoms in an optical dipole trap supplied by a compact fiber laser compliant with onboard applications and decrease the optical power on a very controlled way to obtain evaporative cooling. Preliminary results of ultra-fast evaporative cooling (less than a few seconds) onboard the ZERO-G plane allowed us to reach a regime of temperature compliant with an interrogation time of the order of one second. This method and technology will be tested on the ZERO-G simulator as well.
We perform a precision atom interferometry experiment to test the universality of free fall. Our experiment employs the Bragg atom interferometer with 87Rb atoms either in hyperfine state F = 1 , m F = 0 or F = 2 , m F = 0 , and the wave packets in these two states are diffracted by one pair of Bragg beams alternatively, which is helpful for suppressing common-mode systematic errors. We obtain an Eötvös ratio η 1 − 2 = 0.9 ± 2.7 × 10 − 10 , and set a new record on the precision with improvement of nearly 5 times. This measurement also provides constraint on the difference of the diagonal terms of the mass-energy operator.
Quantum Tests of the Universality of Free FallIn the process of formulating a "theory of everything" that aims to provide a self-contained model of modern physics by unifying all four fundamental interactions, two theoretical frameworks have yielded important contributions: quantum mechanics, which can explain the nature of physics at the most microscopic length scales such as the origin of spectra of electrons bound in atomic systems, and Einstein's general relativity, that conveys our understanding of gravity over the largest distances across the universe.Although no theory of "quantum gravity", that is consistent over all energy scales, exists to date, certain modifications may enable a reconciliation of quantum mechanics and general relativity.These approaches allow for violations of the universality of free fall (UFF), that among Lorentz invariance and local position invariance constitute Einstein's equivalence principle.The UFF states that all bodies, located at the same space-time point, experience the same acceleration in a gravitational field independently of their composition.Because of its central role in modern physics the UFF has been tested extensively in many experiments, most of which utilized classical test masses.Quantum mechanical tests of the UFF differ from classical ones in various aspects such as the coherence length and spin polarization of the test masses.In this thesis, the first inertial-sensitive matter wave interferometer comparing the free fall of two different elements, 87 Rb and 39 K, was realized.This quantum test of the UFF yielded an Eötvös ratio 𝜂 Rb,K = (0.3 ± 5.4) × 10 -7 , and was limited by statistical uncertainty.In this work, an existing apparatus for rubidium interferometry was extended to the use of potassium and the first inertial-sensitive potassium matter wave interferometer with a resolution to gravitational acceleration of 𝜎 K = 3 × 10 -6 m/s 2 after 4096 s integration has been demonstrated.A description of the experiment including the technical realization and the techniques used is provided.Specifically, the challenges imposed by the use of potassium, which in comparison to rubidium has a smaller mass and lower hyperfine energy splitting, are examined.The thesis furthermore discusses an assessment of the systematic effects influencing the dual species measurement and presents future strategies to further improve the performance of the apparatus.As a preliminary result, it was possible to improve the potassium short-term sensitivity to gravitational acceleration to 𝜎 K = 2.1 × 10 -5 m/s 2 / √ Hz.The results of this thesis pave the way for exciting future experiments to be performed in large-scale apparatuses and in space.
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.