arXiv:2107.06819 · Optics Express

Electromagnetic induction imaging: signal detection based on tuned-dressed optical magnetometry

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva, Alessandro Fregosi, Gaetano Napoli, Antonio Vigilante

Published Sep 22, 2021• 0 citations
arXivHTMLPDF

Abstract

A recently introduced tuning-dressed scheme makes a Bell and Bloom magnetometer suited to detect weak variations of a radio-frequency (RF) magnetic field. We envisage the application of such innovative detection scheme as an alternative (or rather as a complement) to RF atomic magnetometers in electromagnetic-induction-imaging apparatuses.

DOI
10.1364/oe.437930

Related papers

Magnetic induction imaging with a cold-atom radio frequency magnetometer

Alessandro Fregosi, C. Gabbanini, S. Gozzini +3 more

The sensitive detection of either static or radio frequency (RF) magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based RF magnetometer in performing 1D and 2D imaging of small metallic objects. It is based on a cold 85Rb atomic sample and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200 pT/Hz in the 5−35 kHz bandwidth range and can resolve a 0.4 mm wide cut in a 0.8 mm thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.

arXiv:2010.04437•Applied Physics Letters•Oct 5, 2020•17 citations

Remote detection magnetometry

Simon Rochester, James Higbie, Bob J. Patton +3 more

Introduction Shortly after the inception of atomic magnetometry, alkali-vapor magnetometers were being used to measure the Earth's magnetic field to unprecedented precision. During the same era, Bell and Bloom first demonstrated all-optical atomic magnetometry through synchronous optical pumping [1] (see Chapters 1 and 6). In this approach, optical-pumping light is frequency- or amplitude-modulated at harmonics of the Larmor frequency ω L to generate a precessing spin polarization within an alkali vapor at finite magnetic field [2, 3]. Although this technique received considerable attention from the atomic physics community for its applicability to optical pumping experiments, Earth's-field alkali-vapor atomic magnetometers continued to rely on radiofrequency (RF) field excitation for several decades (see Chapter 4). Upon the advent of diode lasers addressing alkali and metastable helium transitions, synchronously pumped magnetometers experienced a revival beginning in the late 1980s. In recent years, such magnetometers have found applications in nuclear magnetic resonance detection [4] (see also Chapter 14), quantum control experiments [5], and chip-scale devices intended for spacecraft use [6] (see also Chapters 7 and 15). All-optical magnetometers possess several advantages over devices that employ RF coils. RF-driven magnetometers can suffer from cross-talk if two sensors are placed in close proximity, since the AC magnetic field driving resonance in one vapor cell can adversely affect the other. All-optical magnetometers are free from such interference. When operated in self-oscillating mode [7], RF-driven magnetometers require an added ±90° electronic phase shift in the feedback loop to counter the intrinsic phase shift between the RF field and the probe-beam modulation.

Cambridge University Press eBooks•Mar 7, 2013•0 citations

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu +2 more

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

Physical Review Letters•Aug 27, 2024•24 citations

Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva +1 more

The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.

arXiv:1807.01274•Physical Review Applied•Feb 20, 2019•12 citations

Optical magnetometry with modulated light

Derek F. Jackson Kimball, Szymon Pustelny, Valeriy V. Yashchuk +1 more

Introduction Soon after the development of optical magnetometers based on the radio-optical double resonance method (see Chapter 4), it was realized by Bell and Bloom [1] that an alternative method for optical magnetometry was to modulate the light used for optical pumping at a frequency resonant with the Larmor precession of atomic spins. In a Bell-Bloom optical magnetometer, circularly polarized light resonant with an atomic transition propagates through an atomic vapor along a direction transverse to a magnetic field B . Atomic spins immersed in B precess at the Larmor frequency Ω L , and when the light intensity is modulated at Ω m = Ω L , a resonance in the transmitted light intensity is observed. The essential ideas of the Bell–Bloom optical magnetometer are reviewed in Chapter 1 (Section 1.2), and can be summarized in terms of what Bell and Bloom termed optically driven spin precession: in analogy with a driven harmonic oscillator, in a magnetic field B atomic spins precess at a natural frequency equal to Ω L and the light acts as a driving force oscillating at the modulation frequency Ω m . From another point of view, the Bell-Bloom optical magnetometer can be described in terms of synchronous optical pumping: when Ω m = Ω L , there is a “stroboscopic” resonance in which atoms are optically pumped into a spin state stationary in the frame rotating with Ω L . Depending on the details of the atomic structure, the spin state stationary in the rotating frame can be either a dark state that does not interact with the modulated light or a bright state for which the strength of the light–atom interaction is increased.

Cambridge University Press eBooks•Mar 7, 2013•6 citations

Free Induction Decay Optically Pumped Magnetometers: A Review

Jiarui Liu, Xiao Liu, Yuantian Lu +4 more

Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.

Sensors•Sep 26, 2026•0 citations
A recently introduced tuning-dressed scheme makes a Bell and Bloom magnetometer suited to detect weak variations of a radio-frequency (RF) magnetic field. We envisage the application of such innovative detection scheme as an alternative (or rather as a complement) to RF atomic magnetometers in electromagnetic-induction-imaging apparatuses.
The sensitive detection of either static or radio frequency (RF) magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based RF magnetometer in performing 1D and 2D imaging of small metallic objects. It is based on a cold 85Rb atomic sample and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200 pT/Hz in the 5−35 kHz bandwidth range and can resolve a 0.4 mm wide cut in a 0.8 mm thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.
Introduction Shortly after the inception of atomic magnetometry, alkali-vapor magnetometers were being used to measure the Earth's magnetic field to unprecedented precision. During the same era, Bell and Bloom first demonstrated all-optical atomic magnetometry through synchronous optical pumping [1] (see Chapters 1 and 6). In this approach, optical-pumping light is frequency- or amplitude-modulated at harmonics of the Larmor frequency ω L to generate a precessing spin polarization within an alkali vapor at finite magnetic field [2, 3]. Although this technique received considerable attention from the atomic physics community for its applicability to optical pumping experiments, Earth's-field alkali-vapor atomic magnetometers continued to rely on radiofrequency (RF) field excitation for several decades (see Chapter 4). Upon the advent of diode lasers addressing alkali and metastable helium transitions, synchronously pumped magnetometers experienced a revival beginning in the late 1980s. In recent years, such magnetometers have found applications in nuclear magnetic resonance detection [4] (see also Chapter 14), quantum control experiments [5], and chip-scale devices intended for spacecraft use [6] (see also Chapters 7 and 15). All-optical magnetometers possess several advantages over devices that employ RF coils. RF-driven magnetometers can suffer from cross-talk if two sensors are placed in close proximity, since the AC magnetic field driving resonance in one vapor cell can adversely affect the other. All-optical magnetometers are free from such interference. When operated in self-oscillating mode [7], RF-driven magnetometers require an added ±90° electronic phase shift in the feedback loop to counter the intrinsic phase shift between the RF field and the probe-beam modulation.
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.
The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.
Introduction Soon after the development of optical magnetometers based on the radio-optical double resonance method (see Chapter 4), it was realized by Bell and Bloom [1] that an alternative method for optical magnetometry was to modulate the light used for optical pumping at a frequency resonant with the Larmor precession of atomic spins. In a Bell-Bloom optical magnetometer, circularly polarized light resonant with an atomic transition propagates through an atomic vapor along a direction transverse to a magnetic field B . Atomic spins immersed in B precess at the Larmor frequency Ω L , and when the light intensity is modulated at Ω m = Ω L , a resonance in the transmitted light intensity is observed. The essential ideas of the Bell–Bloom optical magnetometer are reviewed in Chapter 1 (Section 1.2), and can be summarized in terms of what Bell and Bloom termed optically driven spin precession: in analogy with a driven harmonic oscillator, in a magnetic field B atomic spins precess at a natural frequency equal to Ω L and the light acts as a driving force oscillating at the modulation frequency Ω m . From another point of view, the Bell-Bloom optical magnetometer can be described in terms of synchronous optical pumping: when Ω m = Ω L , there is a “stroboscopic” resonance in which atoms are optically pumped into a spin state stationary in the frame rotating with Ω L . Depending on the details of the atomic structure, the spin state stationary in the rotating frame can be either a dark state that does not interact with the modulated light or a bright state for which the strength of the light–atom interaction is increased.
Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.