Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2103.05868 · Physical Review A

Effects of losses on the sensitivity of an actively correlated Mach-Zehnder interferometer

Gao-Feng Jiao, Qiang Wang, Zhifei Yu, L. Q. Chen, Weiping Zhang, Chun-Hua Yuan

Published Jul 30, 2021• 13 citations
arXivHTMLPDF

Abstract

An actively correlated Mach-Zehnder interferometer (ACMZI) renders a number of significant advantages over a conventional Mach-Zehnder interferometer (MZI) with a squeezed vacuum state input such as an active output readout, loss tolerant detection, and multiarms for multiparameter estimation. We theoretically studied the quantum Cram\'er-Rao bound of an ACMZI, where the quantum Fisher information obtained by the phase-averaging method can give the conclusive phase-sensing sensitivity without any external phase reference. We numerically calculate the phase sensitivities with the method of homodyne detection and intensity detection in the presence of losses. Under lossless and very low loss conditions, the ACMZI is operated in a balanced case to beat the standard quantum limit (SQL). As the loss increases, the reduction in sensitivity increases. Fortunately, within a certain range, we can adjust the gain parameters of the beam recombination process to reduce the reduction in sensitivity and realize the sensitivity can continue to beat the SQL in an unbalanced situation. Our scheme provides an optimization method of phase estimation in the presence of losses.

DOI
10.1103/physreva.104.013725

Related papers

Nonlinear phase estimation enhanced by an actively correlated Mach-Zehnder interferometer

Gao-Feng Jiao, Keye Zhang, L. Q. Chen +2 more

A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.

arXiv:2009.08059•Physical Review A•Sep 21, 2020•27 citations

Enhancing phase sensitivity in a Mach-Zehnder interferometer with various detection schemes using SU(1,1) coherent states

Nour-Eddine Abouelkhir, Abdallah Slaoui, El Hassan Saidi +2 more

Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.

arXiv:2406.08007•Journal of the Optical Society of America B•Dec 23, 2024•14 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

Unbalanced beam splitters enabling enhanced phase sensitivity of a Mach-Zehnder interferometer using coherent and squeezed vacuum states

Jiandong Zhang, Shuai Wang

An optical interferometer seeded by coherent and squeezed vacuum states seems to be the most promising platform for gravitational wave detection. Prior studies regarding this estimation protocol focus on the scenario in which the transmittances of two beam splitters are $\frac{1}{2}$. In this paper, with respect to the same inputs, we analyze the phase sensitivity of an unbalanced Mach-Zehnder interferometer (MZI) followed by balanced homodyne measurement. We give the optimal transmittance and demonstrate the advantage of our scheme over a balanced MZI scheme. Additionally, when the average photon number of the coherent state is dominant, the phase sensitivity of our scheme can nearly saturate the single-parameter quantum Cram\'er-Rao bound. Our results may contribute to the development of practical quantum sensing.

Physical Review A•Apr 6, 2023•14 citations

Quantum-enhanced super-sensitivity of Mach–Zehnder interferometer using squeezed Kerr state

Dhiraj Yadav, Gaurav K. Shukla, Priyanka Sharma +1 more

We study the phase super–sensitivity of a Mach–Zehnder interferometer (MZI) with the squeezed Kerr state (SKS) and coherent state as the inputs. We discuss the lower bound in phase sensitivity by considering the quantum Fisher information and the corresponding quantum Cramér–Rao bound. With the help of single intensity detection, intensity difference detection, and homodyne detection schemes, we find that our scheme gives a better sensitivity under both lossless and lossy conditions as compared to the well–known results of the combinations of inputs, such as coherent plus vacuum, coherent plus squeezed vacuum, and double coherent states. Because of the possibility of the generation of SKS with the present available quantum optical techniques, we expect that SKS may be an alternative nonclassical resource for the improvement in the phase super–sensitivity of the MZI in realistic scenarios.

arXiv:2309.04731•APL Quantum•Feb 23, 2024•22 citations

Phase sensitivity via photon-subtraction operations inside Mach-Zehnder interferometer

Zhou, Qisi, Kang, Qinqian, Jiang, Tao +4 more

Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.

arXiv:2505.04499•May 7, 2025•0 citations
An actively correlated Mach-Zehnder interferometer (ACMZI) renders a number of significant advantages over a conventional Mach-Zehnder interferometer (MZI) with a squeezed vacuum state input such as an active output readout, loss tolerant detection, and multiarms for multiparameter estimation. We theoretically studied the quantum Cram'er-Rao bound of an ACMZI, where the quantum Fisher information obtained by the phase-averaging method can give the conclusive phase-sensing sensitivity without any external phase reference. We numerically calculate the phase sensitivities with the method of homodyne detection and intensity detection in the presence of losses. Under lossless and very low loss conditions, the ACMZI is operated in a balanced case to beat the standard quantum limit (SQL). As the loss increases, the reduction in sensitivity increases. Fortunately, within a certain range, we can adjust the gain parameters of the beam recombination process to reduce the reduction in sensitivity and realize the sensitivity can continue to beat the SQL in an unbalanced situation. Our scheme provides an optimization method of phase estimation in the presence of losses.
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.
Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
An optical interferometer seeded by coherent and squeezed vacuum states seems to be the most promising platform for gravitational wave detection. Prior studies regarding this estimation protocol focus on the scenario in which the transmittances of two beam splitters are 12\frac{1}{2}21​. In this paper, with respect to the same inputs, we analyze the phase sensitivity of an unbalanced Mach-Zehnder interferometer (MZI) followed by balanced homodyne measurement. We give the optimal transmittance and demonstrate the advantage of our scheme over a balanced MZI scheme. Additionally, when the average photon number of the coherent state is dominant, the phase sensitivity of our scheme can nearly saturate the single-parameter quantum Cram\'er-Rao bound. Our results may contribute to the development of practical quantum sensing.
We study the phase super–sensitivity of a Mach–Zehnder interferometer (MZI) with the squeezed Kerr state (SKS) and coherent state as the inputs. We discuss the lower bound in phase sensitivity by considering the quantum Fisher information and the corresponding quantum Cramér–Rao bound. With the help of single intensity detection, intensity difference detection, and homodyne detection schemes, we find that our scheme gives a better sensitivity under both lossless and lossy conditions as compared to the well–known results of the combinations of inputs, such as coherent plus vacuum, coherent plus squeezed vacuum, and double coherent states. Because of the possibility of the generation of SKS with the present available quantum optical techniques, we expect that SKS may be an alternative nonclassical resource for the improvement in the phase super–sensitivity of the MZI in realistic scenarios.
Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.