Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2101.00857 · The European Physical Journal D

Amplification of rotation velocity using weak measurements in Sagnac’s interferometer

Jing-Hui Huang, Xue-Ying Duan, Xiangyun Hu

Published Mar 1, 2021• 13 citations
arXivHTMLPDF
DOI
10.1140/epjd/s10053-021-00117-4

Related papers

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

박상준, 김형주, 노재우

•Sep 1, 2012•0 citations

Continuous phase amplification with a Sagnac interferometer

Nathan S. Williams, David J. Starling, P. Ben Dixon +2 more

Bulletin of the American Physical Society•Mar 24, 2011•0 citations

Rotary photon drag at the earth’s rotation rate in a Sagnac interferometer

Sana Ullah, Arif Ullah, Muhammad Imtiaz Khan +2 more

The European Physical Journal Plus•Mar 14, 2025•2 citations

Enhancing the sensitivity of amplification of rotation velocity in Sagnac's interferometer with biased weak measurement

Jing-Hui Huang, Xiangyun Hu, Xue-Ying Duan +1 more

Recently, biased weak measurement(BWM) has shown higher precision than both conventional measurement and standard weak measurement(SWM) in optical metrology. In this paper, we propose a scheme of detecting rotation velocity in Sagnac's interferometer with BWM. In particular, BWM employs an additional reduction of photons in the post-selection by introducing a pre-coupling, and the remaining photons have been shown to be extremely sensitive to the estimated parameter. In addition, our numerical results show that the scheme with BWM can obtain a higher sensitivity than the scheme with SWM.

arXiv:2110.11060•Oct 21, 2021•1 citation

Sagnac effect as viewed by a co-rotating observer

Benno H. W. Hendriks, Gerard Nienhuis

Quantum Optics Journal of the European Optical Society Part B•Jun 1, 1990•1 citation

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

Sang‐Joon Park, Hyoung Joo Kim, Jaewoo Noh

We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

Journal of the Optical Society of Korea•Sep 25, 2012•2 citations
Recently, biased weak measurement(BWM) has shown higher precision than both conventional measurement and standard weak measurement(SWM) in optical metrology. In this paper, we propose a scheme of detecting rotation velocity in Sagnac's interferometer with BWM. In particular, BWM employs an additional reduction of photons in the post-selection by introducing a pre-coupling, and the remaining photons have been shown to be extremely sensitive to the estimated parameter. In addition, our numerical results show that the scheme with BWM can obtain a higher sensitivity than the scheme with SWM.