Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2011.01336 · AVS Quantum Science

Ultraprecision quantum sensing and measurement based on nonlinear hybrid optomechanical systems containing ultracold atoms or atomic Bose–Einstein condensate

Ali Motazedifard, Ali Dalafi, M. H. Naderi

Published Apr 15, 2021• 28 citations
arXivHTMLPDF

Abstract

In this review, the authors study how a hybrid optomechanical system (OMS), in which a quantum micro- or nano-mechanical oscillator is coupled to the electromagnetic radiation pressure, consisting of an ensemble of ultracold atoms or an atomic Bose–Einstein condensate, can be used as an ultraprecision quantum sensor for measuring very weak signals. As is well-known in any precise quantum measurement, the competition between the shot noise and the backaction noise of measurement executes a limitation on the measurement precision which is the so-called standard quantum limit (SQL). In the case where the intensity of the signal is even lower than the SQL, one needs to perform an ultraprecision quantum sensing to beat the SQL. For this purpose, the authors review three important methods for surpassing the SQL in a hybrid OMS: (i) the backaction evading measurement of a quantum nondemolition variable of the system, (ii) the coherent quantum backaction noise cancelation, and (iii) the so-called parametric sensing, the simultaneous signal amplification, and added noise suppression below the SQL. Furthermore, the authors have shown in this article for the first time how the classical fluctuation of the driving laser phase, the so-called laser phase noise, affects the power spectrum of the output optical field in a standard OMS and induces an additional impression noise which makes the total system noise increase above the SQL. Also, for the first time in this review it has been shown that in the standard OMSs, it is impossible to amplify the signal while suppressing the noise below the SQL simultaneously.

DOI
10.1116/5.0035952

Related papers

Force sensing based on coherent quantum noise cancellation in a hybrid optomechanical cavity with squeezed-vacuum injection

Ali Motazedifard, F. Bemani, M. H. Naderi +2 more

We propose and analyse a feasible experimental scheme for a quantum force sensor based on the elimination of backaction noise through coherent quantum noise cancellation (CQNC) in a hybrid atom-cavity optomechanical setup assisted with squeezed vacuum injection. The force detector, which allows for a continuous, broadband detection of weak forces well below the standard quantum limit (SQL), is formed by a single optical cavity simultaneously coupled to a mechanical oscillator and to an ensemble of ultracold atoms. The latter acts as a negative-mass oscillator so that atomic noise exactly cancels the backaction noise from the mechanical oscillator due to destructive quantum interference. Squeezed vacuum injection enforces this cancellation and allows sub-SQL sensitivity to be reached in a very wide frequency band, and at much lower input laser powers.

arXiv:1603.09399•New Journal of Physics•Jul 22, 2016•123 citations

Force sensing beyond the standard quantum limit in a hybrid optomechanical platform

Alolika Roy, Amarendra K. Sarma

We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation-pressure back-action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semitransparent mirror, an ensemble of quantum dots (QDs) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD-induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back-action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak-force sensing beyond the SQL.

Journal of the Optical Society of America B•Jun 15, 2026•0 citations

Overcoming the Standard Quantum Limit with Electro-Optomechanical Hybrid System for Enhanced Force Sensing

Roy, Alolika, Amarendra K. Sarma

We investigate the reduction of measurement-added noise in force sensing by analyzing its power spectral density (PSD) within a hybrid optomechanical system. The setup comprises of an optomechanical cavity equipped with a movable mirror which acts as the mechanical oscillator, a stationary semi-transparent mirror, a superconducting qubit, and an optical parametric amplifier (OPA). By utilizing the concept of coherent quantum noise cancellation (CQNC), we derive the conditions necessary for complete cancellation of back-action force, thereby enhancing force sensitivity. Furthermore, with the gradual increase in the OPA pump gains, we suppress the sensitivity beyond the standard quantum limit (SQL) at a lower value of laser power. The removal of back-action noise, along with the reduction of shot noise, improves force detection capabilities, thereby surpassing the standard quantum limit associated with weak force detection.

arXiv:2409.10694•Sep 16, 2024•0 citations

Force Sensing Beyond the Standard Quantum Limit in a Hybrid Optomechanical Platform

Alolika Roy, Amarendra K. Sarma

We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.

quant-pharXiv:2512.20081•Dec 24, 2025•0 citations

Overcoming the standard quantum limit with an electro-optomechanical hybrid system for enhanced force sensing

Alolika Roy, Amarendra K. Sarma

We investigate the reduction of measurement-added noise in force sensing by analyzing its power spectral density (PSD) within a hybrid optomechanical system. The setup is comprised of an optomechanical cavity equipped with a movable mirror which acts as the mechanical oscillator, a stationary semi-transparent mirror, a superconducting qubit, and an optical parametric amplifier (OPA). By utilizing the concept of coherent quantum noise cancellation (CQNC), we derive the conditions necessary for complete cancellation of back-action force, thereby enhancing force sensitivity. Furthermore, with the gradual increase in the OPA pump gains, we suppress the sensitivity beyond the standard quantum limit (SQL) at a lower value of laser power. The removal of back-action noise, along with the reduction of shot noise, improves force detection capabilities, thereby surpassing the standard quantum limit associated with weak force detection.

Physical Review A•Jan 9, 2025•5 citations

Quantum measurement with cavity optomechanical systems

Chen Xue, Liu Xiao-Wei, Keye Zhang +2 more

Cavity optomechanics originated from the research of interferometric detection of gravitational waves, and later became a fast-growing area of techniques and approaches ranging from the fields of atomic, molecular, and optical physics to nano-science and condensed matter physics as well. Recently, it focused on the exploration of operating mechanical oscillators deep in the quantum regime, with an interest ranging from quantum-classical interface tests to high-precision quantum metrology. In this paper, recent theoretical work of our group in the field of quantum measurement with cavity optomechanical systems is reviewed. We explore the quantum measurement theory and its applications with several unconventional cavity optomechanical schemes working in the quantum regime. This review covers the basics of quantum noises in the cavity optomechanical setups and the resulting standard quantum limit of precision displacement and force measurement. Three novel quantum measurement proposals based on the hybrid optomechanical system are introduced. First, we describe a quantum back-action insulated weak force sensor. It is realized by forming a quantum-mechanics-free subsystem with two optomechanical oscillators of reversed effective mass. Then we introduce a role-reversed atomic optomechanical system which enables the preparation and the quantum tomography of a variety of non-classical states of atoms. In this system, the cavity field acts as a mechanical oscillator driven by the radiation pressure force from an ultracold atomic field. In the end, we recommend a multimode optomechanical transducer that can detect intensities significantly below the single-photon level via adiabatic transfer of the microwave signal to the optical frequency domain. These proposals demonstrate the possible applications of optomechanical devices in understanding of quantum-classical crossover and in achieving quantum measurement limit.

Acta Physica Sinica•Jan 1, 2015•15 citations
In this review, the authors study how a hybrid optomechanical system (OMS), in which a quantum micro- or nano-mechanical oscillator is coupled to the electromagnetic radiation pressure, consisting of an ensemble of ultracold atoms or an atomic Bose–Einstein condensate, can be used as an ultraprecision quantum sensor for measuring very weak signals. As is well-known in any precise quantum measurement, the competition between the shot noise and the backaction noise of measurement executes a limitation on the measurement precision which is the so-called standard quantum limit (SQL). In the case where the intensity of the signal is even lower than the SQL, one needs to perform an ultraprecision quantum sensing to beat the SQL. For this purpose, the authors review three important methods for surpassing the SQL in a hybrid OMS: (i) the backaction evading measurement of a quantum nondemolition variable of the system, (ii) the coherent quantum backaction noise cancelation, and (iii) the so-called parametric sensing, the simultaneous signal amplification, and added noise suppression below the SQL. Furthermore, the authors have shown in this article for the first time how the classical fluctuation of the driving laser phase, the so-called laser phase noise, affects the power spectrum of the output optical field in a standard OMS and induces an additional impression noise which makes the total system noise increase above the SQL. Also, for the first time in this review it has been shown that in the standard OMSs, it is impossible to amplify the signal while suppressing the noise below the SQL simultaneously.
We propose and analyse a feasible experimental scheme for a quantum force sensor based on the elimination of backaction noise through coherent quantum noise cancellation (CQNC) in a hybrid atom-cavity optomechanical setup assisted with squeezed vacuum injection. The force detector, which allows for a continuous, broadband detection of weak forces well below the standard quantum limit (SQL), is formed by a single optical cavity simultaneously coupled to a mechanical oscillator and to an ensemble of ultracold atoms. The latter acts as a negative-mass oscillator so that atomic noise exactly cancels the backaction noise from the mechanical oscillator due to destructive quantum interference. Squeezed vacuum injection enforces this cancellation and allows sub-SQL sensitivity to be reached in a very wide frequency band, and at much lower input laser powers.
We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation-pressure back-action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semitransparent mirror, an ensemble of quantum dots (QDs) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD-induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back-action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak-force sensing beyond the SQL.
We investigate the reduction of measurement-added noise in force sensing by analyzing its power spectral density (PSD) within a hybrid optomechanical system. The setup comprises of an optomechanical cavity equipped with a movable mirror which acts as the mechanical oscillator, a stationary semi-transparent mirror, a superconducting qubit, and an optical parametric amplifier (OPA). By utilizing the concept of coherent quantum noise cancellation (CQNC), we derive the conditions necessary for complete cancellation of back-action force, thereby enhancing force sensitivity. Furthermore, with the gradual increase in the OPA pump gains, we suppress the sensitivity beyond the standard quantum limit (SQL) at a lower value of laser power. The removal of back-action noise, along with the reduction of shot noise, improves force detection capabilities, thereby surpassing the standard quantum limit associated with weak force detection.
We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.
We investigate the reduction of measurement-added noise in force sensing by analyzing its power spectral density (PSD) within a hybrid optomechanical system. The setup is comprised of an optomechanical cavity equipped with a movable mirror which acts as the mechanical oscillator, a stationary semi-transparent mirror, a superconducting qubit, and an optical parametric amplifier (OPA). By utilizing the concept of coherent quantum noise cancellation (CQNC), we derive the conditions necessary for complete cancellation of back-action force, thereby enhancing force sensitivity. Furthermore, with the gradual increase in the OPA pump gains, we suppress the sensitivity beyond the standard quantum limit (SQL) at a lower value of laser power. The removal of back-action noise, along with the reduction of shot noise, improves force detection capabilities, thereby surpassing the standard quantum limit associated with weak force detection.
Cavity optomechanics originated from the research of interferometric detection of gravitational waves, and later became a fast-growing area of techniques and approaches ranging from the fields of atomic, molecular, and optical physics to nano-science and condensed matter physics as well. Recently, it focused on the exploration of operating mechanical oscillators deep in the quantum regime, with an interest ranging from quantum-classical interface tests to high-precision quantum metrology. In this paper, recent theoretical work of our group in the field of quantum measurement with cavity optomechanical systems is reviewed. We explore the quantum measurement theory and its applications with several unconventional cavity optomechanical schemes working in the quantum regime. This review covers the basics of quantum noises in the cavity optomechanical setups and the resulting standard quantum limit of precision displacement and force measurement. Three novel quantum measurement proposals based on the hybrid optomechanical system are introduced. First, we describe a quantum back-action insulated weak force sensor. It is realized by forming a quantum-mechanics-free subsystem with two optomechanical oscillators of reversed effective mass. Then we introduce a role-reversed atomic optomechanical system which enables the preparation and the quantum tomography of a variety of non-classical states of atoms. In this system, the cavity field acts as a mechanical oscillator driven by the radiation pressure force from an ultracold atomic field. In the end, we recommend a multimode optomechanical transducer that can detect intensities significantly below the single-photon level via adiabatic transfer of the microwave signal to the optical frequency domain. These proposals demonstrate the possible applications of optomechanical devices in understanding of quantum-classical crossover and in achieving quantum measurement limit.