arXiv:2007.00638 · PRX Quantum

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

M. Malnou, Michael R. Vissers, J.D. Wheeler, J. Aumentado, J. Hubmayr, Joel N. Ullom, J. Gao

Published Jan 5, 2021• 143 citations
arXivHTMLPDF

Abstract

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit.Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices.It consists of a 50 artificial transmission line whose dispersion allows for a controlled amplification bandwidth.We measure 16.5 +1 -1.3 dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of -63 dBm, in qualitative agreement with theory.Using a theoretical framework that accounts for the SNTJgenerated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier.This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see.This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

DOI
10.1103/prxquantum.2.010302

Related papers

Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing

Michael R. Vissers, R. P. Erickson, H. S. Ku +4 more

We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone we are able to generate parametric amplification using three-wave mixing. The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. Compared to similarly constructed four-wave mixing amplifiers, these devices operate with the RF pump at ~20 dB lower power and at frequencies far from the signal. This will permit easier integration into large scale qubit and detector applications.

arXiv:1509.09280•Applied Physics Letters•Jan 4, 2016•128 citations

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Andrea Giachero, Michael R. Vissers, Jordan Wheeler +6 more

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

arXiv:2403.11354•Journal of Low Temperature Physics•Apr 5, 2024•15 citations

Kinetic Inductance Traveling Wave Parametric Amplifiers Near the Quantum Limit: Methodology and Characterization

Logan A. Howe, Andrea Giachero, Michael R. Vissers +7 more

We present a detailed simulation and design framework for realizing traveling wave parametric amplifiers (TWPAs) using the nonlinear kinetic inductance of disordered superconductors -- in our case niobium-titanium-nitride (NbTiN). These kinetic inductance TWPAs (KITs) operate via three-wave mixing (3WM) to achieve high broadband gain and near-quantum-limited (nQL) noise. Representative fabricated devices -- realized using an inverted microstrip (IMS), dispersion-engineered, artificial transmission line -- demonstrate power gains above 25 dB, bandwidths beyond 3 GHz, and achieve ultimate system noise levels of 1.1 quanta even when operated with no magnetic shielding. These performance metrics are competitive with state-of-the-art Josephson-junction-based TWPAs but involve simpler fabrication and able to providing three orders of magnitude higher dynamic range ($IIP_1 = -68$ dBm, $IIP_3 = -55$ dBm), and high magnetic field resilience -- making KITs an attractive technology for highly multiplexed readout of quantum information and superconducting detector systems.

arXiv:2507.07706•Jul 10, 2025•0 citations

A 4–8 GHz kinetic inductance traveling-wave parametric amplifier using four-wave mixing with near quantum-limited noise performance

Farzad Faramarzi, Ryan Stephenson, Sasha Sypkens +3 more

Kinetic inductance traveling-wave parametric amplifiers (KI-TWPAs) have a wide instantaneous bandwidth with a near quantum-limited noise performance and a relatively high dynamic range. Because of this, they are suitable readout devices for cryogenic detectors and superconducting qubits and have a variety of applications in quantum sensing. This work discusses the design, fabrication, and performance of a KI-TWPA based on four-wave mixing in a NbTiN microstrip transmission line. This device amplifies a signal band from 4 to 8 GHz without contamination from image tones, which are produced in a separate higher frequency band. The 4–8 GHz band is commonly used to read out cryogenic detectors, such as microwave kinetic inductance detectors and Josephson junction-based qubits. We report a measured maximum gain of over 20 dB using four-wave mixing with a 1 dB gain compression point of −58 dBm at 15 dB of gain over that band. The bandwidth and peak gain are tunable by adjusting the pump-tone frequency and power. Using a Y-factor method, we measure an amplifier-added noise of 0.5 ≤ Nadded ≤ 1.5 photons from 4.5 to 8 GHz.

arXiv:2402.11751•APL Quantum•Jul 11, 2024•25 citations

Kinetic inductance traveling-wave amplifiers for multiplexed qubit readout

Leonardo Ranzani, Mustafa Bal, Kin Chung Fong +7 more

We describe a kinetic inductance traveling-wave (KIT) amplifier suitable for superconducting quantum information measurements and characterize its wideband scattering and noise properties. We use mechanical microwave switches to calibrate the four amplifier scattering parameters up to the device input and output connectors at the dilution refrigerator base temperature and a tunable temperature load to characterize the amplifier noise. Finally, we demonstrate the high fidelity simultaneous dispersive readout of two superconducting transmon qubits. The KIT amplifier provides low-noise amplification of both readout tones with readout fidelities of 83% and 89% and negligible effect on qubit lifetime and coherence.

arXiv:1809.11048•Applied Physics Letters•Dec 10, 2018•50 citations

Compact Superconducting Kinetic Inductance Traveling Wave Parametric Amplifiers With On-Chip rf Components

Logan A. Howe, Andrea Giachero, Michael R. Vissers +4 more

Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components – cabling interconnects, bias tees, directional couplers, and diplexers – increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.

arXiv:2503.03608•IEEE Transactions on Applied Superconductivity•Mar 21, 2025•8 citations
We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit.Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices.It consists of a 50 artificial transmission line whose dispersion allows for a controlled amplification bandwidth.We measure 16.5 +1 -1.3 dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of -63 dBm, in qualitative agreement with theory.Using a theoretical framework that accounts for the SNTJgenerated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier.This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see.This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.
We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone we are able to generate parametric amplification using three-wave mixing. The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. Compared to similarly constructed four-wave mixing amplifiers, these devices operate with the RF pump at ~20 dB lower power and at frequencies far from the signal. This will permit easier integration into large scale qubit and detector applications.
Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.
We present a detailed simulation and design framework for realizing traveling wave parametric amplifiers (TWPAs) using the nonlinear kinetic inductance of disordered superconductors -- in our case niobium-titanium-nitride (NbTiN). These kinetic inductance TWPAs (KITs) operate via three-wave mixing (3WM) to achieve high broadband gain and near-quantum-limited (nQL) noise. Representative fabricated devices -- realized using an inverted microstrip (IMS), dispersion-engineered, artificial transmission line -- demonstrate power gains above 25 dB, bandwidths beyond 3 GHz, and achieve ultimate system noise levels of 1.1 quanta even when operated with no magnetic shielding. These performance metrics are competitive with state-of-the-art Josephson-junction-based TWPAs but involve simpler fabrication and able to providing three orders of magnitude higher dynamic range (IIP1=−68IIP_1 = -68IIP1​=−68 dBm, IIP3=−55IIP_3 = -55IIP3​=−55 dBm), and high magnetic field resilience -- making KITs an attractive technology for highly multiplexed readout of quantum information and superconducting detector systems.
Kinetic inductance traveling-wave parametric amplifiers (KI-TWPAs) have a wide instantaneous bandwidth with a near quantum-limited noise performance and a relatively high dynamic range. Because of this, they are suitable readout devices for cryogenic detectors and superconducting qubits and have a variety of applications in quantum sensing. This work discusses the design, fabrication, and performance of a KI-TWPA based on four-wave mixing in a NbTiN microstrip transmission line. This device amplifies a signal band from 4 to 8 GHz without contamination from image tones, which are produced in a separate higher frequency band. The 4–8 GHz band is commonly used to read out cryogenic detectors, such as microwave kinetic inductance detectors and Josephson junction-based qubits. We report a measured maximum gain of over 20 dB using four-wave mixing with a 1 dB gain compression point of −58 dBm at 15 dB of gain over that band. The bandwidth and peak gain are tunable by adjusting the pump-tone frequency and power. Using a Y-factor method, we measure an amplifier-added noise of 0.5 ≤ Nadded ≤ 1.5 photons from 4.5 to 8 GHz.
We describe a kinetic inductance traveling-wave (KIT) amplifier suitable for superconducting quantum information measurements and characterize its wideband scattering and noise properties. We use mechanical microwave switches to calibrate the four amplifier scattering parameters up to the device input and output connectors at the dilution refrigerator base temperature and a tunable temperature load to characterize the amplifier noise. Finally, we demonstrate the high fidelity simultaneous dispersive readout of two superconducting transmon qubits. The KIT amplifier provides low-noise amplification of both readout tones with readout fidelities of 83% and 89% and negligible effect on qubit lifetime and coherence.
Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components – cabling interconnects, bias tees, directional couplers, and diplexers – increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.