Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2004.11344 · Physical Review Research

Long-distance continuous-variable measurement-device-independent quantum key distribution with postselection

Kieran N. Wilkinson, Panagiotis Papanastasiou, Carlo Ottaviani, Tobias Gehring, Stefano Pirandola

Published Sep 16, 2020• 17 citations
arXivHTMLPDF

Abstract

The authors introduce a protocol for measurement-device-independent quantum key distribution under a continuous-variable regime using post-selection. The scheme allows two parties to construct a secret key when communicating through an untrusted relay in the presence of an eavesdropper.
DOI
10.1103/physrevresearch.2.033424

Related papers

Continuous variable measurement device independent quantum conferencing with postselection

Alasdair I. Fletcher, Stefano Pirandola

A continuous variable (CV), measurement device independent (MDI) quantum key distribution (QKD) protocol is analyzed, enabling three parties to connect for quantum conferencing. We utilise a generalised Bell detection at an untrusted relay and a postselection procedure, in which distant parties reconcile on the signs of the displacements of the quadratures of their prepared coherent states. We derive the rate of the protocol under a collective pure-loss attack, demonstrating improved rate-distance performance compared to the equivalent non-post-selected protocol. In the symmetric configuration in which all the parties lie the same distance from the relay, we find a positive key rate over 6 km. Such postselection techniques can be used to improve the rate of multi-party quantum conferencing protocols at longer distances at the cost of reduced performance at shorter distances.

arXiv:2203.14657•Scientific Reports•Oct 15, 2022•8 citations

One-sided device-independent quantum key distribution for two independent parties

Jun Xin, Xiao-Ming Lu, Xingmin Li +1 more

Remote distribution of secret keys is a challenging task in quantum cryptography. A significant step in this direction is the measurement-device independence quantum key distribution (MDI-QKD). For two remote (or independent) parties Alice and Bob who initially no share secret information, the MDI-QKD enables them to share a secret key by the measurement of an untrusted relay. Unfortunately, the MDI-QKD yields the assumption that the devices of both Alice and Bob have to be trusted. Here, we show that QKD between two independent parties can also be realized even if the device of either Alice or Bob is untrusted. We tackle the problem by resorting to the recently developed one-sided device-independent QKD protocol. We derive conditions on the extracted secret key to be unconditionally secure against arbitary attacks in the limit of asymptotic keys. In the presence of Gaussian states and measurements, we theoretically demonstrate our scheme is feasible, which could be an attractive candidate for long distance secret communication.

Optics Express•Mar 27, 2020•14 citations

Parameter Estimation with Almost No Public Communication for Continuous-Variable Quantum Key Distribution

Cosmo Lupo, Carlo Ottaviani, Panagiotis Papanastasiou +1 more

One crucial step in any quantum key distribution (QKD) scheme is parameter estimation. In a typical QKD protocol the users have to sacrifice part of their raw data to estimate the parameters of the communication channel as, for example, the error rate. This introduces a trade-off between the secret key rate and the accuracy of parameter estimation in the finite-size regime. Here we show that continuous-variable QKD is not subject to this constraint as the whole raw keys can be used for both parameter estimation and secret key generation, without compromising the security. First, we show that this property holds for measurement-device-independent (MDI) protocols, as a consequence of the fact that in a MDI protocol the correlations between Alice and Bob are postselected by the measurement performed by an untrusted relay. This result is then extended beyond the MDI framework by exploiting the fact that MDI protocols can simulate device-dependent one-way QKD with arbitrarily high precision.

arXiv:1712.00743•Physical Review Letters•Jun 1, 2018•49 citations

Continuous-variable measurement-device-independent quantum key distribution using squeezed states

Yichen Zhang, Zhengyu Li, Song Yu +3 more

A continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol using squeezed states is proposed where the two legitimate partners send Gaussian-modulated squeezed states to an untrusted third party to realize the measurement. Security analysis shows that the protocol can not only defend all detector side channels, but also attain higher secret key rates than the coherent-state-based protocol. We also present a method to improve the squeezed-state CV-MDI QKD protocol by adding proper Gaussian noise to the reconciliation side. It is found that there is an optimal added noise to optimize the performance of the protocol in terms of both key rates and maximal transmission distances. The resulting protocol shows the potential of long-distance secure communication using the CV-MDI QKD protocol.

arXiv:1406.0973•Physical Review A•Nov 18, 2014•115 citations

Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

Yijia Zhao, Yichen Zhang, Bingjie Xu +2 more

The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

arXiv:1711.04225•Physical Review A•Apr 17, 2018•62 citations

Continuous-variable measurement-device-independent quantum key distribution

Zhengyu Li, Yichen Zhang, Feihu Xu +2 more

We propose a continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, in which detection is conducted by an untrusted third party. Our protocol can defend all detector side channels, which seriously threaten the security of a practical CV QKD system. Its security analysis against arbitrary collective attacks is derived based on the fact that the entanglement-based scheme of CV-MDI QKD is equivalent to the conventional CV QKD with coherent states and heterodyne detection. We find that the maximal total transmission distance is achieved by setting the untrusted third party close to one of the legitimate users. Furthermore, an alternate detection scheme, a special application of CV-MDI QKD, is proposed to enhance the security of the standard CV QKD system.

arXiv:1312.4655•Physical Review A•May 7, 2014•224 citations
A continuous variable (CV), measurement device independent (MDI) quantum key distribution (QKD) protocol is analyzed, enabling three parties to connect for quantum conferencing. We utilise a generalised Bell detection at an untrusted relay and a postselection procedure, in which distant parties reconcile on the signs of the displacements of the quadratures of their prepared coherent states. We derive the rate of the protocol under a collective pure-loss attack, demonstrating improved rate-distance performance compared to the equivalent non-post-selected protocol. In the symmetric configuration in which all the parties lie the same distance from the relay, we find a positive key rate over 6 km. Such postselection techniques can be used to improve the rate of multi-party quantum conferencing protocols at longer distances at the cost of reduced performance at shorter distances.
Remote distribution of secret keys is a challenging task in quantum cryptography. A significant step in this direction is the measurement-device independence quantum key distribution (MDI-QKD). For two remote (or independent) parties Alice and Bob who initially no share secret information, the MDI-QKD enables them to share a secret key by the measurement of an untrusted relay. Unfortunately, the MDI-QKD yields the assumption that the devices of both Alice and Bob have to be trusted. Here, we show that QKD between two independent parties can also be realized even if the device of either Alice or Bob is untrusted. We tackle the problem by resorting to the recently developed one-sided device-independent QKD protocol. We derive conditions on the extracted secret key to be unconditionally secure against arbitary attacks in the limit of asymptotic keys. In the presence of Gaussian states and measurements, we theoretically demonstrate our scheme is feasible, which could be an attractive candidate for long distance secret communication.
One crucial step in any quantum key distribution (QKD) scheme is parameter estimation. In a typical QKD protocol the users have to sacrifice part of their raw data to estimate the parameters of the communication channel as, for example, the error rate. This introduces a trade-off between the secret key rate and the accuracy of parameter estimation in the finite-size regime. Here we show that continuous-variable QKD is not subject to this constraint as the whole raw keys can be used for both parameter estimation and secret key generation, without compromising the security. First, we show that this property holds for measurement-device-independent (MDI) protocols, as a consequence of the fact that in a MDI protocol the correlations between Alice and Bob are postselected by the measurement performed by an untrusted relay. This result is then extended beyond the MDI framework by exploiting the fact that MDI protocols can simulate device-dependent one-way QKD with arbitrarily high precision.
A continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol using squeezed states is proposed where the two legitimate partners send Gaussian-modulated squeezed states to an untrusted third party to realize the measurement. Security analysis shows that the protocol can not only defend all detector side channels, but also attain higher secret key rates than the coherent-state-based protocol. We also present a method to improve the squeezed-state CV-MDI QKD protocol by adding proper Gaussian noise to the reconciliation side. It is found that there is an optimal added noise to optimize the performance of the protocol in terms of both key rates and maximal transmission distances. The resulting protocol shows the potential of long-distance secure communication using the CV-MDI QKD protocol.
The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.
We propose a continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, in which detection is conducted by an untrusted third party. Our protocol can defend all detector side channels, which seriously threaten the security of a practical CV QKD system. Its security analysis against arbitrary collective attacks is derived based on the fact that the entanglement-based scheme of CV-MDI QKD is equivalent to the conventional CV QKD with coherent states and heterodyne detection. We find that the maximal total transmission distance is achieved by setting the untrusted third party close to one of the legitimate users. Furthermore, an alternate detection scheme, a special application of CV-MDI QKD, is proposed to enhance the security of the standard CV QKD system.