Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2001.07353

Fiber-based narrowband bright squeezed light generation by double-pass parametric amplification

Tan, Tianyi, Changsheng Yang, Qilai Zhao, Chengzi Huang, Xianchao Guan, Zhongmin Yang, Shanhui Xu

Published Jan 21, 2020• 1 citation
arXivHTMLPDF

Abstract

The squeezed states of light become more and more important in the fields of quantum enhanced precision measurement and quantum information. To get this vital continuous variable quantum resource, the generation of squeezed states of light becomes a key factor. In this paper, a compact telecom fiber-based bright squeezed light (BSL) generator is demonstrated. To our knowledge, this is the first time that BSL has been reported in a fiber-based system to date. To obtain the BSL, a double-pass parametric amplifier based on surface-coated lithium niobate waveguide is employed. When the 1550 nm seed laser of the parametric amplifier is blocked, a stable 1.85 dB squeezed vacuum is obtained. With injected seed power of 80 μW, an output power of 18 μW and a squeezing value of 1.04 dB are achieved of the BSL at 1550 nm. Due to the good mode matching in the fiber and the absence of the resonant cavity, this flexible and compact BSL generator has the potential to be useful in out-of-the-laboratory quantum technologies. Moreover, the BSL has a narrow spectral width of 30 kHz, which is inherited from a narrow-linewidth single-frequency seed laser. In addition to being free from the wavelength-dependent losses, the narrowband BSL is also beneficial to improve the signal-to-noise ratio of quantum-enhanced precision measurement.

DOI
10.48550/arxiv.2001.07353

Related papers

Generation of bright squeezed light at 1.5 m telecommunication band and its Wigner function reconstruction

孙志妮 SUN Zhi-ni, Feng Jin-Xia, Wan Zhen-Ju +1 more

The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.

Acta Physica Sinica•Jan 1, 2016•4 citations

Generation of audio-band frequency squeezed light at 1.34 μm

Feng Jin-Xia, 杜京师 DU Jing-shi, Jin Xiao-Li +2 more

Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.

Acta Physica Sinica•Jan 1, 2018•2 citations

Generation of a squeezed state at 1.55 μm with periodically poled LiNbO 3

Qin Liu, Jinxia Feng, Hong Li +2 more

We report on the generation of a squeezing vacuum at 1.55 μm using an optical parametric amplifier based on periodically poled LiNbO 3 . Using three specifically designed narrow linewidth mode cleaners as the spatial mode and noise filter of the laser at 1.55 μm and 775 nm, the squeezed vacuum of up to 3.0 dB below the shot noise level at 1.55 μm is experimentally obtained. This system is compatible with standard telecommunication optical fibers, and will be useful for continuous variable long-distance quantum communication and distributed quantum computing.

Chinese Physics B•Oct 1, 2012•5 citations

Compact fiber-coupled narrowband two-mode squeezed light source

Umang Jain, Jae Woong Choi, Christopher Hull +1 more

Quantum correlated states of light, such as squeezed states, are a fundamental resource for the development of quantum technologies, as they are needed for applications in quantum metrology, quantum computation, and quantum communications. It is thus critical to develop compact, efficient, and robust sources to generate such states. Here, we report on a compact, narrowband, fiber-coupled source of two-mode squeezed states of light at 795 nm based on four-wave mixing (FWM) in an 85Rb atomic vapor. The source is designed in a small modular form factor, with two input fiber-coupled beams, the seed and pump beams required for the FWM, and two output fibers, one for each of the modes of the squeezed state. The system is optimized for low pump power (135 mW) to achieve a maximum intensity-difference squeezing of 4.4 dB after the output of fibers at an analysis frequency of 1 MHz. The narrowband nature of the source makes it ideal for atomic-based quantum sensing and quantum networking configurations that rely on atomic quantum memories. Such a source paves the way for a versatile and portable platform for applications in quantum information science.

arXiv:2507.03755•Optics Letters•Jul 17, 2025•0 citations

Generation of 10-dB squeezed light from a broadband waveguide optical parametric amplifier with improved phase locking method

Kazuki Hirota, Takahiro Kashiwazaki, Gyeongmin Ha +10 more

We report generation of 10.1\pm0.2-dB squeezed light from a broadband periodically poled lithium niobate (PPLN) waveguide optical parametric amplifier (OPA). Based on our previous report where a similar PPLN waveguide shows 8.3-dB squeezing [T. Kashiwazaki et al., Appl. Phys. Lett. 122, 234003 (2023)], we reduce phase fluctuations and overall optical losses in the measurement system. In particular, we introduce a novel phase detection technique that does not require tapping a part of the squeezed light to get a phase locking signal. We use a phase-detection OPA seeded by a tapped probe and pump light before a squeezer OPA. This configuration breaks the conventional trade-off between generating a phase-locking signal with high-signal-to-noise ratio and suppressing degradation of squeezing level caused by optical tapping. With all these improvements, the phase fluctuation angle is reduced from 14 mrad to 9 mrad, and the total optical loss from 12\% to 8\%. Achieving more than 10 dB of squeezing by the broadband waveguide OPA is a significant step towards realization of fault-tolerant ultra-fast universal optical quantum computation.

quant-pharXiv:2511.15082•Nov 20, 2025•1 citation

A Bright Squeezed Light Source for Quantum Sensing

Wenhai Yang, Wenting Diao, Chunxiao Cai +8 more

The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.

Chemosensors•Dec 25, 2022•13 citations
The squeezed states of light become more and more important in the fields of quantum enhanced precision measurement and quantum information. To get this vital continuous variable quantum resource, the generation of squeezed states of light becomes a key factor. In this paper, a compact telecom fiber-based bright squeezed light (BSL) generator is demonstrated. To our knowledge, this is the first time that BSL has been reported in a fiber-based system to date. To obtain the BSL, a double-pass parametric amplifier based on surface-coated lithium niobate waveguide is employed. When the 1550 nm seed laser of the parametric amplifier is blocked, a stable 1.85 dB squeezed vacuum is obtained. With injected seed power of 80 μW, an output power of 18 μW and a squeezing value of 1.04 dB are achieved of the BSL at 1550 nm. Due to the good mode matching in the fiber and the absence of the resonant cavity, this flexible and compact BSL generator has the potential to be useful in out-of-the-laboratory quantum technologies. Moreover, the BSL has a narrow spectral width of 30 kHz, which is inherited from a narrow-linewidth single-frequency seed laser. In addition to being free from the wavelength-dependent losses, the narrowband BSL is also beneficial to improve the signal-to-noise ratio of quantum-enhanced precision measurement.
The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.
Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.
We report on the generation of a squeezing vacuum at 1.55 μm using an optical parametric amplifier based on periodically poled LiNbO 3 . Using three specifically designed narrow linewidth mode cleaners as the spatial mode and noise filter of the laser at 1.55 μm and 775 nm, the squeezed vacuum of up to 3.0 dB below the shot noise level at 1.55 μm is experimentally obtained. This system is compatible with standard telecommunication optical fibers, and will be useful for continuous variable long-distance quantum communication and distributed quantum computing.
Quantum correlated states of light, such as squeezed states, are a fundamental resource for the development of quantum technologies, as they are needed for applications in quantum metrology, quantum computation, and quantum communications. It is thus critical to develop compact, efficient, and robust sources to generate such states. Here, we report on a compact, narrowband, fiber-coupled source of two-mode squeezed states of light at 795 nm based on four-wave mixing (FWM) in an 85Rb atomic vapor. The source is designed in a small modular form factor, with two input fiber-coupled beams, the seed and pump beams required for the FWM, and two output fibers, one for each of the modes of the squeezed state. The system is optimized for low pump power (135 mW) to achieve a maximum intensity-difference squeezing of 4.4 dB after the output of fibers at an analysis frequency of 1 MHz. The narrowband nature of the source makes it ideal for atomic-based quantum sensing and quantum networking configurations that rely on atomic quantum memories. Such a source paves the way for a versatile and portable platform for applications in quantum information science.
We report generation of 10.1\pm0.2-dB squeezed light from a broadband periodically poled lithium niobate (PPLN) waveguide optical parametric amplifier (OPA). Based on our previous report where a similar PPLN waveguide shows 8.3-dB squeezing [T. Kashiwazaki et al., Appl. Phys. Lett. 122, 234003 (2023)], we reduce phase fluctuations and overall optical losses in the measurement system. In particular, we introduce a novel phase detection technique that does not require tapping a part of the squeezed light to get a phase locking signal. We use a phase-detection OPA seeded by a tapped probe and pump light before a squeezer OPA. This configuration breaks the conventional trade-off between generating a phase-locking signal with high-signal-to-noise ratio and suppressing degradation of squeezing level caused by optical tapping. With all these improvements, the phase fluctuation angle is reduced from 14 mrad to 9 mrad, and the total optical loss from 12\% to 8\%. Achieving more than 10 dB of squeezing by the broadband waveguide OPA is a significant step towards realization of fault-tolerant ultra-fast universal optical quantum computation.
The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.