arXiv:1912.12530 · Advanced Quantum Technologies

Reframing SU(1,1) Interferometry

Carlton M. Caves

Published Mar 25, 2020• 52 citations
arXivHTMLPDF

Abstract

Abstract SU(1,1) interferometry, proposed in a classic 1986 paper by Yurke, McCall, and Klauder, involves squeezing, displacing, and then unsqueezing two bosonic modes. It has, over the past decade, been implemented in a variety of experiments. Here, SU(1,1) interferometry is taken apart, to see how and why it ticks. SU(1,1) interferometry arises naturally as the two‐mode version of active‐squeezing‐enhanced, back‐action‐evading measurements aimed at detecting the phase‐space displacement of a harmonic oscillator subjected to a classical force. Truncating an SU(1,1) interferometer, by omitting the second two‐mode squeezer, leaves a prototype that uses the entanglement of two‐mode squeezing to detect and characterize a disturbance on one of the two modes from measurement statistics gathered from both modes.

DOI
10.1002/qute.201900138

Related papers

Two-mode squeezing and SU(1,1) interferometry with trapped ions

Jeremy Metzner, A. Quinn, S. Brudney +4 more

We experimentally implement circuits of one- and two-mode operations on two motional modes of a single trapped ion. This is achieved by implementing the required displacement, squeezing, two-mode squeezing, and beam-splitter operations using oscillating electric potentials applied to the trap electrodes. The resulting electric fields drive the modes resonantly or parametrically without the need for optical forces. As a demonstration, we implement SU(2) and SU(1,1) interferometers with phase sensitivities near the Cram\'er-Rao bound. We report a maximum sensitivity of a SU(2) interferometer within 0.67(5) dB of the standard quantum limit (SQL) as well as a single- and two-mode SU(1,1) sensitivity of 5.9(2) dB and 4.5(2) dB below the SQL, respectively.

arXiv:2312.10847•Physical Review A•Aug 14, 2024•18 citations

Hybrid SU(1,1) Interferometry in Optomechanics

Chao Meng, Emil Zeuthen, Polina R. Sharapova

In nondegenerate SU(1,1) interferometers, beam splitters are replaced by two-mode squeezers, enabling sub-shot-noise sensitivity without input squeezing and robustness to detection losses by quantum entanglement. We propose a hybrid implementation in optomechanics where one "arm" is a mechanical mode undergoing two consecutive, mode-matched interactions with a traveling optical field (constituting the other arm). Such engineered interactions allow for sub-shot-noise phase detection even in the presence of mechanical thermal noise and optical losses, advancing precision interferometry in hybrid systems.

arXiv:2509.22248•Physical Review Letters•Apr 23, 2026•0 citations

Active SU(1,1) atom interferometry

D Linnemann, J Schulz, W Muessel +5 more

Abstract Active interferometers use amplifying elements for beam splitting and recombination. We experimentally implement such a device by using spin exchange in a Bose–Einstein condensate. The two interferometry modes are initially empty spin states that get spontaneously populated in the process of parametric amplification. This nonlinear mechanism scatters atoms into both modes in a pairwise fashion and generates a non-classical state. Finally, a matched second period of spin exchange is performed that nonlinearly amplifies the output signal and maps the phase onto readily detectable first moments. Depending on the accumulated phase this nonlinear readout can reverse the initial dynamics and deamplify the entangled state back to empty spin states. This sequence is described in the framework of SU(1,1) mode transformations and compared to the SU(2) angular momentum description of passive interferometers.

arXiv:1711.04552•Quantum Science and Technology•Aug 30, 2017•18 citations

Pumped-Up SU(1,1) Interferometry

Stuart S. Szigeti, Robert J. Lewis-Swan, Simon A. Haine

Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: Only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled to these "side modes" is typically small, this limits the interferometer's absolute sensitivity. We propose an alternative "pumped-up" approach where all the input particles participate in the phase measurement and show how this can be implemented in spinor Bose-Einstein condensates and hybrid atom-light systems-both of which have experimentally realized SU(1,1) interferometry. We demonstrate that pumped-up schemes are capable of surpassing the shot-noise limit with respect to the total number of input particles and are never worse than conventional SU(1,1) interferometry. Finally, we show that pumped-up schemes continue to excel-both absolutely and in comparison to conventional SU(1,1) interferometry-in the presence of particle losses, poor particle-resolution detection, and noise on the relative phase difference between the two side modes. Pumped-up SU(1,1) interferometry therefore pushes the advantages of conventional SU(1,1) interferometry into the regime of high absolute sensitivity, which is a necessary condition for useful quantum-enhanced devices.

arXiv:1610.07689•Physical Review Letters•Apr 11, 2017•137 citations

PHASE MEASUREMENTS WITH A TWO-MODE SQUEEZED STATE OF LIGHT.

Gupta, Prasoon

Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.

•Jan 1, 2019•0 citations

SU(1,1) interferometry via four-wave mixing in Rb

Travis Horrom, Brian E. Anderson, Prasoon Gupta +1 more

Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].

•Jan 1, 2015•3 citations
Abstract SU(1,1) interferometry, proposed in a classic 1986 paper by Yurke, McCall, and Klauder, involves squeezing, displacing, and then unsqueezing two bosonic modes. It has, over the past decade, been implemented in a variety of experiments. Here, SU(1,1) interferometry is taken apart, to see how and why it ticks. SU(1,1) interferometry arises naturally as the two‐mode version of active‐squeezing‐enhanced, back‐action‐evading measurements aimed at detecting the phase‐space displacement of a harmonic oscillator subjected to a classical force. Truncating an SU(1,1) interferometer, by omitting the second two‐mode squeezer, leaves a prototype that uses the entanglement of two‐mode squeezing to detect and characterize a disturbance on one of the two modes from measurement statistics gathered from both modes.
We experimentally implement circuits of one- and two-mode operations on two motional modes of a single trapped ion. This is achieved by implementing the required displacement, squeezing, two-mode squeezing, and beam-splitter operations using oscillating electric potentials applied to the trap electrodes. The resulting electric fields drive the modes resonantly or parametrically without the need for optical forces. As a demonstration, we implement SU(2) and SU(1,1) interferometers with phase sensitivities near the Cram\'er-Rao bound. We report a maximum sensitivity of a SU(2) interferometer within 0.67(5) dB of the standard quantum limit (SQL) as well as a single- and two-mode SU(1,1) sensitivity of 5.9(2) dB and 4.5(2) dB below the SQL, respectively.
In nondegenerate SU(1,1) interferometers, beam splitters are replaced by two-mode squeezers, enabling sub-shot-noise sensitivity without input squeezing and robustness to detection losses by quantum entanglement. We propose a hybrid implementation in optomechanics where one "arm" is a mechanical mode undergoing two consecutive, mode-matched interactions with a traveling optical field (constituting the other arm). Such engineered interactions allow for sub-shot-noise phase detection even in the presence of mechanical thermal noise and optical losses, advancing precision interferometry in hybrid systems.
Abstract Active interferometers use amplifying elements for beam splitting and recombination. We experimentally implement such a device by using spin exchange in a Bose–Einstein condensate. The two interferometry modes are initially empty spin states that get spontaneously populated in the process of parametric amplification. This nonlinear mechanism scatters atoms into both modes in a pairwise fashion and generates a non-classical state. Finally, a matched second period of spin exchange is performed that nonlinearly amplifies the output signal and maps the phase onto readily detectable first moments. Depending on the accumulated phase this nonlinear readout can reverse the initial dynamics and deamplify the entangled state back to empty spin states. This sequence is described in the framework of SU(1,1) mode transformations and compared to the SU(2) angular momentum description of passive interferometers.
Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: Only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled to these "side modes" is typically small, this limits the interferometer's absolute sensitivity. We propose an alternative "pumped-up" approach where all the input particles participate in the phase measurement and show how this can be implemented in spinor Bose-Einstein condensates and hybrid atom-light systems-both of which have experimentally realized SU(1,1) interferometry. We demonstrate that pumped-up schemes are capable of surpassing the shot-noise limit with respect to the total number of input particles and are never worse than conventional SU(1,1) interferometry. Finally, we show that pumped-up schemes continue to excel-both absolutely and in comparison to conventional SU(1,1) interferometry-in the presence of particle losses, poor particle-resolution detection, and noise on the relative phase difference between the two side modes. Pumped-up SU(1,1) interferometry therefore pushes the advantages of conventional SU(1,1) interferometry into the regime of high absolute sensitivity, which is a necessary condition for useful quantum-enhanced devices.
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.
Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].