arXiv:1912.06848 · Physical Review Applied

Pumping Dynamics of Cold-Atom Experiments in a Single Vacuum Chamber

Jean-Marc Martin, Satyanarayana Bade, William Dubosclard, Murtaza Ali Khan, Seungjin Kim, Barry M. Garraway, Carlos L. Garrido Alzar

Published Jul 18, 2019• 7 citations
arXivHTMLPDF

Abstract

Compact ultracold-atom sensors using a single vacuum chamber have their stability ultimately constrained by vacuum dynamics. To speed evacuation, the straightforward approach is to increase the pumping speed, which implies increasing pump size and sensor volume. This investigation of the dynamics of sputtered ion pumps (SIPs) describes the main physical mechanisms with a nonlinear model for ion-current pump-down in the low-pressure regime. One pumping process suggests that a structured cathode could curtail the increase in pump size, or at least maintain the trapping cross section of the electrode---a result that may be important in the design and development of miniature ion pumps.

DOI
10.1103/physrevapplied.12.014033

Related papers

Pumping dynamics of cold-atom experiments in a single vacuum chamber

Jean-Marc Martin, Satyanarayana Bade, William Dubosclard +4 more

A nonlinear analytical model for the pressure dynamics in a vacuum chamber, pumped with a sputter ion pump (SIP), is proposed, discussed and experimentally evaluated. The model describes the physics of the pumping mechanism of SIPs in the context of a cold-atom experiment. By using this model, we fit pump-down curves of our vacuum system to extract the relevant physical parameters characterizing its pressure dynamics. The aim of this investigation is the optimization of cold-atom experiments in terms of reducing the dead time for quantum sensing using atom interferometry. We develop a calibration method to improve the precision in pressure measurements via the ion current in SIPs. Our method is based on a careful analysis of the gas conductance and pumping in order to reliably link the pressure readings at the SIP with the actual pressure in the vacuum (science) chamber. Our results are in agreement with the existence of essentially two pumping regimes determined by the pressure level in the system. In particular, we find our results in agreement with the well-known fact that for a given applied voltage, at low pressures, the discharge current efficiently sputters pumping material from the pump’s electrodes. This process sets the leading pumping mechanism in this limit. At high pressures, the discharge current drops and the pumping is mainly performed by the already sputtered material.

•Jul 18, 2019•4 citations

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Bethany J. Little, Gregory W. Hoth, Justin Christensen +5 more

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

arXiv:2101.01051•AVS Quantum Science•Jul 15, 2021•39 citations

Ultra-High Vacuum Cells Realized by Miniature Ion Pump Using High-Efficiency Plasma Source

Yuichi Kurashima, Atsuhiko Maeda, Naoto Oshima +4 more

In recent years, there has been significant interest in quantum technology, characterized by the emergence of quantum computers boasting immense processing power, ultra-sensitive quantum sensors, and ultra-precise atomic clocks. Miniaturization of quantum devices using cold atoms necessitates the employment of an ultra-high vacuum miniature cell with a pressure of approximately 10−6 Pa or even lower. In this study, we developed an ultra-high vacuum cell realized by a miniature ion pump using a high-efficiency plasma source. Initially, an unsealed miniature ion pump was introduced into a vacuum chamber, after which the ion pump’s discharge current, depending on vacuum pressures, was evaluated. Subsequently, a miniature vacuum cell was fabricated by hermetically sealing the miniature vacuum pump. The cell was successfully evacuated by a miniature ion pump down to an ultra-high vacuum region, which was derived by the measured discharge current. Our findings demonstrate the feasibility of achieving an ultra-high vacuum cell necessary for the operation of miniature quantum devices.

Sensors•Jun 20, 2024•4 citations

Vacuum characterization of a compact room-temperature trapped ion system

Yuhi Aikyo, Geert Vrijsen, Thomas W. Noel +3 more

We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2 cm3, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011 Torr, which is sufficient for the majority of current trapped ion experiments.

arXiv:2007.07950•Applied Physics Letters•Dec 7, 2020•12 citations

Characterization of alkali metal dispensers and non-evaporable getter pumps in ultrahigh vacuum systems for cold atomic sensors

David R. Scherer, David B. Fenner, Joel M. Hensley

A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.

arXiv:1203.1202•Journal of Vacuum Science & Technology A Vacuum Surfaces and Films•Oct 9, 2012•31 citations

Centilitre-scale vacuum chamber for compact ultracold quantum technologies

Oliver S. Burrow, Paul F. Osborn, Edward Boughton +5 more

Compact ultra-high vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centilitre-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fibre. A cold atom demonstrator based on the vacuum cell delivers $10^7$ laser-cooled $^{87}$Rb atoms per second, using minimal electrical power. With continuous Rb gas emission active pumping yields a $10^{-7}\,$mbar equilibrium pressure, and passive pumping stabilises to $3\times 10^{-6}\,$mbar, with a $17\,$day time constant. A passively-pumped vacuum cell, with no Rb dispensing, has currently kept a similar pressure for a year. The passive-pumping vacuum lifetime is several years, estimated from short-term He throughput, with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.

•Jan 19, 2021•1 citation
Compact ultracold-atom sensors using a single vacuum chamber have their stability ultimately constrained by vacuum dynamics. To speed evacuation, the straightforward approach is to increase the pumping speed, which implies increasing pump size and sensor volume. This investigation of the dynamics of sputtered ion pumps (SIPs) describes the main physical mechanisms with a nonlinear model for ion-current pump-down in the low-pressure regime. One pumping process suggests that a structured cathode could curtail the increase in pump size, or at least maintain the trapping cross section of the electrode---a result that may be important in the design and development of miniature ion pumps.
A nonlinear analytical model for the pressure dynamics in a vacuum chamber, pumped with a sputter ion pump (SIP), is proposed, discussed and experimentally evaluated. The model describes the physics of the pumping mechanism of SIPs in the context of a cold-atom experiment. By using this model, we fit pump-down curves of our vacuum system to extract the relevant physical parameters characterizing its pressure dynamics. The aim of this investigation is the optimization of cold-atom experiments in terms of reducing the dead time for quantum sensing using atom interferometry. We develop a calibration method to improve the precision in pressure measurements via the ion current in SIPs. Our method is based on a careful analysis of the gas conductance and pumping in order to reliably link the pressure readings at the SIP with the actual pressure in the vacuum (science) chamber. Our results are in agreement with the existence of essentially two pumping regimes determined by the pressure level in the system. In particular, we find our results in agreement with the well-known fact that for a given applied voltage, at low pressures, the discharge current efficiently sputters pumping material from the pump’s electrodes. This process sets the leading pumping mechanism in this limit. At high pressures, the discharge current drops and the pumping is mainly performed by the already sputtered material.
Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.
In recent years, there has been significant interest in quantum technology, characterized by the emergence of quantum computers boasting immense processing power, ultra-sensitive quantum sensors, and ultra-precise atomic clocks. Miniaturization of quantum devices using cold atoms necessitates the employment of an ultra-high vacuum miniature cell with a pressure of approximately 10−6 Pa or even lower. In this study, we developed an ultra-high vacuum cell realized by a miniature ion pump using a high-efficiency plasma source. Initially, an unsealed miniature ion pump was introduced into a vacuum chamber, after which the ion pump’s discharge current, depending on vacuum pressures, was evaluated. Subsequently, a miniature vacuum cell was fabricated by hermetically sealing the miniature vacuum pump. The cell was successfully evacuated by a miniature ion pump down to an ultra-high vacuum region, which was derived by the measured discharge current. Our findings demonstrate the feasibility of achieving an ultra-high vacuum cell necessary for the operation of miniature quantum devices.
We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2 cm3, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011 Torr, which is sufficient for the majority of current trapped ion experiments.
A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.
Compact ultra-high vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centilitre-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fibre. A cold atom demonstrator based on the vacuum cell delivers 10710^7107 laser-cooled 87^{87}87Rb atoms per second, using minimal electrical power. With continuous Rb gas emission active pumping yields a 10−7 10^{-7}\,10−7mbar equilibrium pressure, and passive pumping stabilises to 3×10−6 3\times 10^{-6}\,3×10−6mbar, with a 17 17\,17day time constant. A passively-pumped vacuum cell, with no Rb dispensing, has currently kept a similar pressure for a year. The passive-pumping vacuum lifetime is several years, estimated from short-term He throughput, with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.