Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1907.05977 · Quantum Studies Mathematics and Foundations

Diffraction-based interaction-free measurements

Spencer Rogers, Yakir Aharonov, Cyril Elouard, Andrew N. Jordan

Published Sep 14, 2019• 1 citation
arXivHTMLPDF
DOI
10.1007/s40509-019-00205-6

Related papers

Resonance interaction-free measurement

Harry Paul, Mladen Pavičić

International Journal of Theoretical Physics•Oct 1, 1996•24 citations

Loss-resilient, x ray interaction-free measurements

Ron Cohen, S. Shwartz, Eliahu Cohen

Interaction-free measurement (IFM) is a promising technique for low-dose detection and imaging, offering the unique advantage of probing an object with an overall reduced absorption of the interrogating photons. We propose an experiment to demonstrate IFM in the single x ray photon regime. The proposed scheme relies on the triple-Laue (LLL) symmetric x ray interferometer, where each Laue diffraction acts as a lossy beam splitter. In contrast to many quantum effects which are highly vulnerable to loss, we show that an experimental demonstration of this effect in the x ray regime is feasible and can achieve detection with reduced dose and high IFM efficiency even in the presence of substantial loss in the system. The latter aspect is claimed to be a general property of IFM based on our theoretical analysis. We scrutinize two suitable detection schemes that offer a dose reduction of up to half compared with direct detection. The successful demonstration of IFM with x rays promises intriguing possibilities for measurements with reduced dose, mainly advantageous for biological samples, where radiation damage is a significant limitation.

arXiv:2407.06369•Optica Quantum•Nov 27, 2024•0 citations

Interaction-free measurements with degrees of freedom of light

G. T. C. Cruz, J. A. O. Huguenin, W. F. Balthazar

Physics Letters A•Aug 20, 2026•0 citations

Efficient two-port electron beam splitter via a quantum interaction-free measurement

Yujia Yang, Chung-Soo Kim, Richard G. Hobbs +2 more

Semitransparent mirrors are standard elements in light optics for splitting light beams or creating two versions of the same image. Such mirrors do not exist in electron optics, although they could be beneficial in existing techniques such as electron interferometry and holography and could enable alternative electron imaging and spectroscopy techniques. We propose a design for an electron beam splitter using the concept of quantum interaction-free measurement (IFM). The design combines an electron resonator with a weak phase grating. Fast switching gates allow electrons to enter and exit the resonator. While in the resonator, the phase grating transfers intensity from the direct beam into one of the weakly diffracted beams at each pass. To make the beam splitter an efficient two-port splitter, the intensity in all other diffracted beams is blocked by an aperture. The IFM principle minimizes the loss of total intensity by this aperture. We use a scattering matrix method to analyze the performance of the beam splitter, including the effects of inelastic scattering in the phase grating. This design can be generalized to beam splitters for not only electrons, but also photons, neutrons, atoms, and other quantum mechanical systems.

arXiv:1808.03363•Physical Review A•Oct 17, 2018•11 citations

Experimental Realization of Interaction‐free Measurementsa

Paul G. Kwiat, Harald Weinfurter, Thomas Herzog +2 more

Annals of the New York Academy of Sciences•Apr 1, 1995•41 citations

Reduced damage in electron microscopy by using interaction-free measurement and conditional reillumination

Akshay Agarwal, Karl K. Berggren, Yuri J. van Staaden +1 more

Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.

arXiv:1901.09702•Physical Review A•Jun 5, 2019•12 citations
Interaction-free measurement (IFM) is a promising technique for low-dose detection and imaging, offering the unique advantage of probing an object with an overall reduced absorption of the interrogating photons. We propose an experiment to demonstrate IFM in the single x ray photon regime. The proposed scheme relies on the triple-Laue (LLL) symmetric x ray interferometer, where each Laue diffraction acts as a lossy beam splitter. In contrast to many quantum effects which are highly vulnerable to loss, we show that an experimental demonstration of this effect in the x ray regime is feasible and can achieve detection with reduced dose and high IFM efficiency even in the presence of substantial loss in the system. The latter aspect is claimed to be a general property of IFM based on our theoretical analysis. We scrutinize two suitable detection schemes that offer a dose reduction of up to half compared with direct detection. The successful demonstration of IFM with x rays promises intriguing possibilities for measurements with reduced dose, mainly advantageous for biological samples, where radiation damage is a significant limitation.
Semitransparent mirrors are standard elements in light optics for splitting light beams or creating two versions of the same image. Such mirrors do not exist in electron optics, although they could be beneficial in existing techniques such as electron interferometry and holography and could enable alternative electron imaging and spectroscopy techniques. We propose a design for an electron beam splitter using the concept of quantum interaction-free measurement (IFM). The design combines an electron resonator with a weak phase grating. Fast switching gates allow electrons to enter and exit the resonator. While in the resonator, the phase grating transfers intensity from the direct beam into one of the weakly diffracted beams at each pass. To make the beam splitter an efficient two-port splitter, the intensity in all other diffracted beams is blocked by an aperture. The IFM principle minimizes the loss of total intensity by this aperture. We use a scattering matrix method to analyze the performance of the beam splitter, including the effects of inelastic scattering in the phase grating. This design can be generalized to beam splitters for not only electrons, but also photons, neutrons, atoms, and other quantum mechanical systems.
Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.