Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1905.03143 · Optica

Wide-field SU(1,1) interferometer

G. Frascella, Eugeniy E. Mikhailov, Naoto Takanashi, Roman V. Zakharov, O. V. Tikhonova, M. V. Chekhova

Published Sep 12, 2019• 63 citations
arXivHTMLPDF

Abstract

An ${\rm SU(1,1)}$ interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field ${\rm SU(1,1)}$ interferometer, where the use of a focusing element enables spatially multimode operation within a broad angle. Over this angle, the interference phase is found to be flat. This property is important for the high sensitivity to the phase front disturbance. Further, $-4.3\pm0.7$ dB quadrature squeezing, an essential requirement to the high sensitivity, is experimentally demonstrated for plane-wave modes inside the interferometer. Such an interferometer is useful not only for quantum metrology, but also in remote sensing, enhanced sub-shot-noise imaging, and quantum information processing.

DOI
10.1364/optica.6.001233

Related papers

Wide-field SU(1,1) interferometer

Gaetano Frascella, Eugeniy E. Mikhailov, Naoto Takanashi +3 more

An SU(1,1) interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field SU(1,1) interferometer, where the use of a focusing element enables spatially multimode operation within a broad angle. Over this angle, the interference phase is found to be flat. This property is important for the high sensitivity to the phase front disturbance. Further, -4.3 +/- 0.7 dB quadrature squeezing, an essential requirement to the high sensitivity, is experimentally demonstrated for plane-wave modes inside the interferometer. Such an interferometer is useful not only for quantum metrology, but also in remote sensing, enhanced sub-shot-noise imaging, and quantum information processing. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

•Sep 20, 2019•13 citations

Phase sensitivity of spatially broadband high-gain SU(1,1) interferometers

D. Scharwald, T. Meier, Polina R. Sharapova

Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the light generated in these interferometers results in the destruction of their phase sensitivity, requiring advanced interferometric configurations for multimode light. Moreover, in contrast to the single-mode case, time-ordering effects play an important role for the high-gain regime in the multimode scenario and must be taken into account for a correct estimation of the phase sensitivity. In this paper, we present a theoretical description of spatially multimode $\mathrm{SU}(1,1)$ interferometers operating at low and high parametric gains. Our approach is based on a step-by-step solution of a system of integro-differential equations for each nonlinear interaction region. We focus on interferometers with diffraction compensation, where focusing elements such as a parabolic mirror are used to compensate for the divergence of the light. We investigate plane-wave and Gaussian pumping and show that for any parametric gain, there exists a region of phases for which the phase sensitivity surpasses the standard shot-noise scaling and discuss the regimes where it approaches the Heisenberg scale. Finally, we arrive at insightful analytical expressions for the phase sensitivity that are valid for both low and high parametric gain and demonstrate how it depends on the number of spatial modes of the system.

arXiv:2307.01723•Physical Review Research•Nov 16, 2023•13 citations

Experimental reconstruction of spatial Schmidt modes for a wide-field SU(1,1) interferometer

Gaetano Frascella, Roman V. Zakharov, Olga V. Tikhonova +1 more

Abstract We study the spatial mode content at the output of a wide-field interferometer, i.e. a nonlinear interferometer comprising two coherently-pumped spatially-multimode optical parametric amplifiers placed in sequence with a focusing element in between. This device is expected to provide a phase sensitivity below the shot-noise limit for multiple modes over a broad angular range. To reconstruct the spatial modes and their weights, we implement a simple method based on the acquisition of only intensity distributions. The eigenmode decomposition of the field is obtained through the measurement of the covariance of intensities at different spatial points. We investigate both the radial and azimuthal (orbital angular momentum) modes and show that their total number is large enough to enable applications of the interferometer in spatially-resolved phase measurements.

arXiv:1909.05026•Laser Physics•Oct 30, 2019•8 citations

Quantum Interferometer Combining Squeezing and Parametric Amplification

Xiaojie Zuo, Zhihui Yan, Yanni Feng +4 more

High precision interferometers are the building blocks of precision metrology and the ultimate interferometric sensitivity is limited by the quantum noise. Here, we propose and experimentally demonstrate a compact quantum interferometer involving two optical parametric amplifiers and the squeezed states generated within the interferometer are directly used for the phase-sensing quantum state. By both squeezing shot noise and amplifying phase-sensing intensity the sensitivity improvement of 4.86±0.24 dB beyond the standard quantum limit is deterministically realized and a minimum detectable phase smaller than that of all present interferometers under the same phase-sensing intensity is achieved. This interferometric system has significantly potential applications in a variety of measurements for tiny variances of physical quantities.

arXiv:2005.01911•Physical Review Letters•May 1, 2020•78 citations

Quantum Sensing of Birefringence Beyond the Classical Limit with a Hyper-Squeezed SU(1,1) Interferometer

Samata Gokhale, Netanel P. Yaish, Michal Natan +3 more

Quantum interferometric sensing plays a crucial role in a wide range of applications, including quantum metrology, quantum imaging, and quantum lithography, where minute phase shifts carry valuable physical information. The strength of quantum sensing lies in surpassing classical sensitivity limits, particularly through the use of quantum correlations and squeezing to suppress optical shot noise. Birefringence sensing is crucial for various applications, as it provides detailed information about the material's structure, stress, composition, and environmental conditions. We present an interferometric scheme for detecting unknown small birefringence beyond the shot-noise limit of sensitivity that leverages the hyper-squeezing (squeezed in both number-phase and polarization correlations) within a pair of polarized nonlinear SU(1,1) interferometers, coupled by the birefringence. Specifically, two pairs of crossed-polarization nonlinear media, both generate and measure two-mode quantum light that is squeezed and polarization-entangled. We present a complete theoretical analysis of the interferometer's sensitivity to small birefringence under realistic conditions of gain and internal loss, illuminating the potential for enhancement of the sensitivity by 3-15dB in practical, real-world experiments (the exact achievable enhancement is governed solely by the loss).

quant-pharXiv:2603.08857•Optica Quantum•Mar 11, 2026•1 citation

Detection Loss Tolerant Supersensitive Phase Measurement with an SU(1,1) Interferometer

Mathieu Manceau, Gerd Leuchs, Farid Ya Khalili +1 more

In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.

arXiv:1705.02662•Physical Review Letters•Nov 29, 2017•171 citations
An SU(1,1){\rm SU(1,1)}SU(1,1) interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field SU(1,1){\rm SU(1,1)}SU(1,1) interferometer, where the use of a focusing element enables spatially multimode operation within a broad angle. Over this angle, the interference phase is found to be flat. This property is important for the high sensitivity to the phase front disturbance. Further, −4.3±0.7-4.3\pm0.7−4.3±0.7 dB quadrature squeezing, an essential requirement to the high sensitivity, is experimentally demonstrated for plane-wave modes inside the interferometer. Such an interferometer is useful not only for quantum metrology, but also in remote sensing, enhanced sub-shot-noise imaging, and quantum information processing.
An SU(1,1) interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field SU(1,1) interferometer, where the use of a focusing element enables spatially multimode operation within a broad angle. Over this angle, the interference phase is found to be flat. This property is important for the high sensitivity to the phase front disturbance. Further, -4.3 +/- 0.7 dB quadrature squeezing, an essential requirement to the high sensitivity, is experimentally demonstrated for plane-wave modes inside the interferometer. Such an interferometer is useful not only for quantum metrology, but also in remote sensing, enhanced sub-shot-noise imaging, and quantum information processing. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the light generated in these interferometers results in the destruction of their phase sensitivity, requiring advanced interferometric configurations for multimode light. Moreover, in contrast to the single-mode case, time-ordering effects play an important role for the high-gain regime in the multimode scenario and must be taken into account for a correct estimation of the phase sensitivity. In this paper, we present a theoretical description of spatially multimode SU(1,1)\mathrm{SU}(1,1)SU(1,1) interferometers operating at low and high parametric gains. Our approach is based on a step-by-step solution of a system of integro-differential equations for each nonlinear interaction region. We focus on interferometers with diffraction compensation, where focusing elements such as a parabolic mirror are used to compensate for the divergence of the light. We investigate plane-wave and Gaussian pumping and show that for any parametric gain, there exists a region of phases for which the phase sensitivity surpasses the standard shot-noise scaling and discuss the regimes where it approaches the Heisenberg scale. Finally, we arrive at insightful analytical expressions for the phase sensitivity that are valid for both low and high parametric gain and demonstrate how it depends on the number of spatial modes of the system.
Abstract We study the spatial mode content at the output of a wide-field interferometer, i.e. a nonlinear interferometer comprising two coherently-pumped spatially-multimode optical parametric amplifiers placed in sequence with a focusing element in between. This device is expected to provide a phase sensitivity below the shot-noise limit for multiple modes over a broad angular range. To reconstruct the spatial modes and their weights, we implement a simple method based on the acquisition of only intensity distributions. The eigenmode decomposition of the field is obtained through the measurement of the covariance of intensities at different spatial points. We investigate both the radial and azimuthal (orbital angular momentum) modes and show that their total number is large enough to enable applications of the interferometer in spatially-resolved phase measurements.
High precision interferometers are the building blocks of precision metrology and the ultimate interferometric sensitivity is limited by the quantum noise. Here, we propose and experimentally demonstrate a compact quantum interferometer involving two optical parametric amplifiers and the squeezed states generated within the interferometer are directly used for the phase-sensing quantum state. By both squeezing shot noise and amplifying phase-sensing intensity the sensitivity improvement of 4.86±0.24 dB beyond the standard quantum limit is deterministically realized and a minimum detectable phase smaller than that of all present interferometers under the same phase-sensing intensity is achieved. This interferometric system has significantly potential applications in a variety of measurements for tiny variances of physical quantities.
Quantum interferometric sensing plays a crucial role in a wide range of applications, including quantum metrology, quantum imaging, and quantum lithography, where minute phase shifts carry valuable physical information. The strength of quantum sensing lies in surpassing classical sensitivity limits, particularly through the use of quantum correlations and squeezing to suppress optical shot noise. Birefringence sensing is crucial for various applications, as it provides detailed information about the material's structure, stress, composition, and environmental conditions. We present an interferometric scheme for detecting unknown small birefringence beyond the shot-noise limit of sensitivity that leverages the hyper-squeezing (squeezed in both number-phase and polarization correlations) within a pair of polarized nonlinear SU(1,1) interferometers, coupled by the birefringence. Specifically, two pairs of crossed-polarization nonlinear media, both generate and measure two-mode quantum light that is squeezed and polarization-entangled. We present a complete theoretical analysis of the interferometer's sensitivity to small birefringence under realistic conditions of gain and internal loss, illuminating the potential for enhancement of the sensitivity by 3-15dB in practical, real-world experiments (the exact achievable enhancement is governed solely by the loss).
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.