Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1810.08242 · Physical Review A

Conclusive precision bounds for SU(1,1) interferometers

Chenglong You, Sushovit Adhikari, Xiaoping Ma, Masahide Sasaki, Masahiro Takeoka, Jonathan P. Dowling

Published Apr 24, 2019• 48 citations
arXivHTMLPDF

Abstract

In this paper, we revisit the quantum Fisher information (QFI) calculation in SU(1,1) interferometer considering different phase configurations. When one of the input modes is a vacuum state, we show by using phase averaging, different phase configurations give the same QFI. In addition, by casting the phase estimation as a two-parameter estimation problem, we show that the calculation of the quantum Fisher information matrix (QFIM) is necessary in general. Particularly, within this setup, the phase-averaging method is equivalent to a two-parameter estimation problem. We also calculate the phase sensitivity for different input states using QFIM approach.

DOI
10.1103/physreva.99.042122

Related papers

Ultimate precision limit of SU(2) and SU(1,1) interferometers in noisy metrology

Zeng, Jie, Dong Li, L. Q. Chen +2 more

The quantum Fisher information (QFI) in SU(2) and SU(1,1) interferometers was considered, and the QFI-only calculation was overestimated. In general, the phase estimation as a two-parameter estimation problem, and the quantum Fisher information matrix (QFIM) is necessary. In this paper, we theoretically generalize the model developed by Escher et al [Nature Physics 7, 406 (2011)] to the QFIM case with noise and study the ultimate precision limits of SU(2) and SU(1,1) interferometers with photon losses because photon losses as a very usual noise may happen to the phase measurement process. Using coherent state and squeezed vacuum state as a specific example, we numerically analyze the variation of the overestimated QFI with the loss coefficient, and find its disappearance and recovery phenomenon.

arXiv:2302.09823•Feb 20, 2023•0 citations

Precision of Parameter Estimation in Quantum Metrology

Chenglong You

The fundamental precision limit of an interferometer is crucial since it bounds the best possible sensitivity one could achieve using such a device. This thesis will focus on several different interferometers and try to give the ultimate precision bounds by carefully counting all the resources used in the interferometers. The thesis begins with the basics of the quantum state of light. The fundamentals of quantum metrology are also reviewed and discussed. More specifically, the terminology of classical and quantum Cram\'er-Rao bound and classical and quantum Fisher information are introduced. Chapter 3 discusses the conclusive precision bounds in two-mode interferometer such as Mach-Zehnder interferometer (MZI) and SU(1,1) interferometer. I revisit the quantum Fisher information approach of these two interferometers and show the discrepancy of phase sensitivity on the physically same setup. Then I establish fundamental precision estimation bounds for such device, due to the reason that many works of literature fail to accurately count the resources and knowledge of phase-to-be-estimated used in the interferometers. The analysis suggests that for a MZI, one can never do better than SNL in phase sensitivity, when an input to one of the two ports is the vacuum. If one does not allow the detector to use any external phase reference or power resource, then the precision is limited by the SNL. For a SU(1,1) interferometer, firstly, when one of the input states is restricted to be a vacuum state, I showed that by using either the phase-averaging method or the quantum Fisher information matrix method, different phase configurations of the SU(1,1) interferometer result in the same QFI. Secondly, I compared the results of the phase-averaging method and the quantum Fisher information matrix method, and then I argued that for an SU(1,1) interferometer, phase averaging or quantum Fisher information matrix method is generally required, and they are equivalent. Finally, I used the quantum Fisher information matrix method to calculate the precision limit for other common input states, such as two coherent state inputs or coherent state with squeezed vacuum inputs. In chapter 4, I will consider a passive multi-mode interferometer for multiparameter phase estimation. It was suggested that optical networks with relatively inexpensive overhead---single photon Fock states, passive optical elements, and single photon detection---can show significant improvements over classical strategies for single-parameter estimation, when the number of modes in the network is small. In this chapter, I analytically compute the quantum Cramer-Rao bound to show these

Civil War Book Review•Mar 18, 2019•0 citations

Intramode-correlation-enhanced phase sensitivities in an SU(1,1) interferometer

Qian-Kun Gong, Xiu-Ling Hu, Dong Li +3 more

We theoretically derive the lower and upper bounds of quantum Fisher information (QFI) of an SU(1,1) interferometer whatever the input state chosen. According to the QFI, the crucial resource for quantum enhancement is shown to be large intramode correlations indicated by the Mandel $Q$ parameter. The subtraction of photons from the squeezed vacuum state has the effect of increasing the average photon number of the new field state, as well as the intramode correlations. For example, for a coherent state $\ensuremath{\bigotimes}$ a squeezed vacuum state with a given fixed input mean number of photons as the input, if $p$ photons are subtracted from the squeezed-vacuum state before inputting the SU(1,1) interferometer, the phase sensitivities can be improved due to the intramode-correlation increment.

arXiv:1609.03308•Physical Review A•Sep 6, 2017•49 citations

Enhancement of Sensitivity by Initial Phase Matching in SU(1,1) Interferometers*

Xiao Xiao, Hongbin Liang, Guolong Li +1 more

Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.

Communications in Theoretical Physics•Jan 1, 2019•7 citations

Phase Estimation in Linear and Nonlinear Interferometers

Sushovit Adhikari

Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.

Civil War Book Review•Feb 22, 2019•0 citations

Phase estimation via multi-photon subtraction inside the SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Youke Xu +3 more

Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.

arXiv:2311.14612•Physica Scripta•Jul 4, 2024•8 citations
In this paper, we revisit the quantum Fisher information (QFI) calculation in SU(1,1) interferometer considering different phase configurations. When one of the input modes is a vacuum state, we show by using phase averaging, different phase configurations give the same QFI. In addition, by casting the phase estimation as a two-parameter estimation problem, we show that the calculation of the quantum Fisher information matrix (QFIM) is necessary in general. Particularly, within this setup, the phase-averaging method is equivalent to a two-parameter estimation problem. We also calculate the phase sensitivity for different input states using QFIM approach.
The quantum Fisher information (QFI) in SU(2) and SU(1,1) interferometers was considered, and the QFI-only calculation was overestimated. In general, the phase estimation as a two-parameter estimation problem, and the quantum Fisher information matrix (QFIM) is necessary. In this paper, we theoretically generalize the model developed by Escher et al [Nature Physics 7, 406 (2011)] to the QFIM case with noise and study the ultimate precision limits of SU(2) and SU(1,1) interferometers with photon losses because photon losses as a very usual noise may happen to the phase measurement process. Using coherent state and squeezed vacuum state as a specific example, we numerically analyze the variation of the overestimated QFI with the loss coefficient, and find its disappearance and recovery phenomenon.
The fundamental precision limit of an interferometer is crucial since it bounds the best possible sensitivity one could achieve using such a device. This thesis will focus on several different interferometers and try to give the ultimate precision bounds by carefully counting all the resources used in the interferometers. The thesis begins with the basics of the quantum state of light. The fundamentals of quantum metrology are also reviewed and discussed. More specifically, the terminology of classical and quantum Cram\'er-Rao bound and classical and quantum Fisher information are introduced. Chapter 3 discusses the conclusive precision bounds in two-mode interferometer such as Mach-Zehnder interferometer (MZI) and SU(1,1) interferometer. I revisit the quantum Fisher information approach of these two interferometers and show the discrepancy of phase sensitivity on the physically same setup. Then I establish fundamental precision estimation bounds for such device, due to the reason that many works of literature fail to accurately count the resources and knowledge of phase-to-be-estimated used in the interferometers. The analysis suggests that for a MZI, one can never do better than SNL in phase sensitivity, when an input to one of the two ports is the vacuum. If one does not allow the detector to use any external phase reference or power resource, then the precision is limited by the SNL. For a SU(1,1) interferometer, firstly, when one of the input states is restricted to be a vacuum state, I showed that by using either the phase-averaging method or the quantum Fisher information matrix method, different phase configurations of the SU(1,1) interferometer result in the same QFI. Secondly, I compared the results of the phase-averaging method and the quantum Fisher information matrix method, and then I argued that for an SU(1,1) interferometer, phase averaging or quantum Fisher information matrix method is generally required, and they are equivalent. Finally, I used the quantum Fisher information matrix method to calculate the precision limit for other common input states, such as two coherent state inputs or coherent state with squeezed vacuum inputs. In chapter 4, I will consider a passive multi-mode interferometer for multiparameter phase estimation. It was suggested that optical networks with relatively inexpensive overhead---single photon Fock states, passive optical elements, and single photon detection---can show significant improvements over classical strategies for single-parameter estimation, when the number of modes in the network is small. In this chapter, I analytically compute the quantum Cramer-Rao bound to show these
We theoretically derive the lower and upper bounds of quantum Fisher information (QFI) of an SU(1,1) interferometer whatever the input state chosen. According to the QFI, the crucial resource for quantum enhancement is shown to be large intramode correlations indicated by the Mandel QQQ parameter. The subtraction of photons from the squeezed vacuum state has the effect of increasing the average photon number of the new field state, as well as the intramode correlations. For example, for a coherent state $\ensuremath{\bigotimes}$ a squeezed vacuum state with a given fixed input mean number of photons as the input, if ppp photons are subtracted from the squeezed-vacuum state before inputting the SU(1,1) interferometer, the phase sensitivities can be improved due to the intramode-correlation increment.
Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.
Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.
Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.