Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1809.00627 · Physical Review A

Sources of heading errors in optically pumped magnetometers operated in the Earth's magnetic field

G. Oelsner, V. Schultze, R.P.J. IJsselsteijn, Florian Wittkämper, Ronny Stolz

Published Jan 16, 2019• 49 citations
arXivHTMLPDF

Abstract

When optically pumped magnetometers are aimed for use in the Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement results. Measurement errors and inaccuracies related to the heading of the sensor can be an even more severe problem in the case of special operational configurations, such as the use of strong off-resonant pumping. We systematically study the main contributions to the heading error in systems that promise high magnetic field resolutions at the Earth's magnetic field strengths, namely the nonlinear Zeeman splitting and the orientation-dependent light shift. The good correspondence of our theoretical analysis to experimental data demonstrates that both of these effects are related to a heading-dependent modification of the interaction between the laser light and the dipole moment of the atoms. Also, our results promise a compensation of both effects using a combination of clockwise and counterclockwise circular polarization.

DOI
10.1103/physreva.99.013420

Related papers

Asymmetric Heading Errors and its Suppression in Atomic Magnetometers

Yue Chang, Yuhao Guo, Shuangai Wan +1 more

Precession frequencies measured by optically pumped scalar magnetometers are dependent on the relative angle between the sensor and the external magnetic field. This dependence is known to be induced mainly by the nonlinear Zeeman effect and the orientation-dependent light shift, resulting in the so-called heading errors if the magnetic field orientation is not well known or is not stable. In this work, we find that the linear nuclear Zeeman effect has also a significant impact on the heading errors. It not only shifts the precession frequency but causes asymmetry: the heading error for sensors orienting in the upper-half plane with respect to the external field is different from the case when the sensors work in the lower-half plane. This heading error also depends on the relative direction of the probe laser to the driving magnetic field. With a left-handed circularly-polarized pump laser, when the probe laser is parallel to the driving field, the angular dependence of the precession frequency is smaller when the sensor is in the upper plane. Otherwise, when they are perpendicular to each other, the heading error is smaller when the sensor is in the lower plane. Furthermore, to suppress the heading error, we propose to utilize a small magnetic field along the propagation direction of the pump laser. By tuning the magnitude of this auxiliary field, the heading-error curve is flattened around different angles, which can increase the accuracy in practice when the magnetometer works around a certain orientation angle.

•Feb 5, 2021•0 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•6 citations

Performance analysis of an optically pumped magnetometer in Earth’s magnetic field

G. Oelsner, V. Schultze, R.P.J. IJsselsteijn +1 more

Abstract We experimentally investigate the influence of the orientation of optically pumped magnetometers in Earth’s magnetic field. We focus our analysis to an operational mode that promises femtotesla field resolutions at such field strengths. For this so-called light-shift dispersed $M_{z}$ Mz (LSD-Mz) regime, we focus on the key parameters defining its performance. That are the reconstructed Larmor frequency, the transfer function between output signal and magnetic field amplitude as well as the shot noise limited field resolution. We demonstrate that due to the use of two well balanced laser beams for optical pumping with different helicities the heading error as well as the field sensitivity of a detector both are only weakly influenced by the heading in a large orientation angle range.

arXiv:1908.06639•EPJ Quantum Technology•Dec 1, 2019•27 citations

Suppression of the Nonlinear Zeeman Effect and Heading Error in Earth-Field-Range Alkali-Vapor Magnetometers

Guzhi Bao, Arne Wickenbrock, Simon Rochester +2 more

The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.

arXiv:1708.05262•Physical Review Letters•Jan 17, 2018•69 citations

Production and detection of atomic hexadecapole at Earth’s magnetic field

Víctor M. Acosta, Marcis P. Auzinsh, Wojciech Gawlik +9 more

Optical magnetometers measure magnetic fields with extremely high precision and without cryogenics. However, at geomagnetic fields, important for applications from landmine removal to archaeology, they suffer from nonlinear Zeeman splitting, leading to systematic dependence on sensor orientation. We present experimental results on a method of eliminating this systematic error, using the hexadecapole atomic polarization moment. In particular, we demonstrate selective production of the atomic hexadecapole moment at Earth's magnetic field and verify its immunity to nonlinear Zeeman splitting. This technique promises to eliminate directional errors in all-optical atomic magnetometers, potentially improving their measurement accuracy by several orders of magnitude.

arXiv:0709.4283•Optics Express•Jul 15, 2008•27 citations

Production and detection of atomic hexadecapole at Earth’s magnetic field

Víctor M. Acosta, Marcis P. Auzinsh, Wojciech Gawlik +8 more

Optical magnetometers measure magnetic fields with extremely high precision and without cryogenics. However, at geomagnetic fields, important for applications from landmine removal to archaeology, they suffer from nonlinear Zeeman splitting, leading to systematic dependence on sensor orientation. We present experimental results on a method of eliminating this systematic error, using the hexadecapole atomic polarization moment. In particular, we demonstrate selective production of the atomic hexadecapole moment at Earth’s magnetic field and verify its immunity to nonlinear Zeeman splitting. This technique promises to eliminate directional errors in all-optical atomic magnetometers, potentially improving their measurement accuracy by several orders of magnitude.

Frontiers in Optics•Jan 1, 2007•1 citation
When optically pumped magnetometers are aimed for use in the Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement results. Measurement errors and inaccuracies related to the heading of the sensor can be an even more severe problem in the case of special operational configurations, such as the use of strong off-resonant pumping. We systematically study the main contributions to the heading error in systems that promise high magnetic field resolutions at the Earth's magnetic field strengths, namely the nonlinear Zeeman splitting and the orientation-dependent light shift. The good correspondence of our theoretical analysis to experimental data demonstrates that both of these effects are related to a heading-dependent modification of the interaction between the laser light and the dipole moment of the atoms. Also, our results promise a compensation of both effects using a combination of clockwise and counterclockwise circular polarization.
Precession frequencies measured by optically pumped scalar magnetometers are dependent on the relative angle between the sensor and the external magnetic field. This dependence is known to be induced mainly by the nonlinear Zeeman effect and the orientation-dependent light shift, resulting in the so-called heading errors if the magnetic field orientation is not well known or is not stable. In this work, we find that the linear nuclear Zeeman effect has also a significant impact on the heading errors. It not only shifts the precession frequency but causes asymmetry: the heading error for sensors orienting in the upper-half plane with respect to the external field is different from the case when the sensors work in the lower-half plane. This heading error also depends on the relative direction of the probe laser to the driving magnetic field. With a left-handed circularly-polarized pump laser, when the probe laser is parallel to the driving field, the angular dependence of the precession frequency is smaller when the sensor is in the upper plane. Otherwise, when they are perpendicular to each other, the heading error is smaller when the sensor is in the lower plane. Furthermore, to suppress the heading error, we propose to utilize a small magnetic field along the propagation direction of the pump laser. By tuning the magnitude of this auxiliary field, the heading-error curve is flattened around different angles, which can increase the accuracy in practice when the magnetometer works around a certain orientation angle.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.
Abstract We experimentally investigate the influence of the orientation of optically pumped magnetometers in Earth’s magnetic field. We focus our analysis to an operational mode that promises femtotesla field resolutions at such field strengths. For this so-called light-shift dispersed MzM_{z}Mz​ Mz (LSD-Mz) regime, we focus on the key parameters defining its performance. That are the reconstructed Larmor frequency, the transfer function between output signal and magnetic field amplitude as well as the shot noise limited field resolution. We demonstrate that due to the use of two well balanced laser beams for optical pumping with different helicities the heading error as well as the field sensitivity of a detector both are only weakly influenced by the heading in a large orientation angle range.
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.
Optical magnetometers measure magnetic fields with extremely high precision and without cryogenics. However, at geomagnetic fields, important for applications from landmine removal to archaeology, they suffer from nonlinear Zeeman splitting, leading to systematic dependence on sensor orientation. We present experimental results on a method of eliminating this systematic error, using the hexadecapole atomic polarization moment. In particular, we demonstrate selective production of the atomic hexadecapole moment at Earth's magnetic field and verify its immunity to nonlinear Zeeman splitting. This technique promises to eliminate directional errors in all-optical atomic magnetometers, potentially improving their measurement accuracy by several orders of magnitude.
Optical magnetometers measure magnetic fields with extremely high precision and without cryogenics. However, at geomagnetic fields, important for applications from landmine removal to archaeology, they suffer from nonlinear Zeeman splitting, leading to systematic dependence on sensor orientation. We present experimental results on a method of eliminating this systematic error, using the hexadecapole atomic polarization moment. In particular, we demonstrate selective production of the atomic hexadecapole moment at Earth’s magnetic field and verify its immunity to nonlinear Zeeman splitting. This technique promises to eliminate directional errors in all-optical atomic magnetometers, potentially improving their measurement accuracy by several orders of magnitude.