A new concept multi-stage Zeeman decelerator: experimental implementation

Theo Cremers, Simon Chefdeville, Niek Janssen, Edwin Sweers, Sven Koot, Peter Claus, Sebastiaan Y. T. van de Meerakker

Published Feb 14, 2017• 0 citations
arXivHTMLPDF

Abstract

We demonstrate the successful experimental implementation of a multi-stage Zeeman decelerator utilizing the new concept described in the accompanying paper. The decelerator consists of an array of 25 hexapoles and 24 solenoids. The performance of the decelerator in acceleration, deceleration and guiding modes is characterized using beams of metastable Helium ($^3S$) atoms. Up to 60% of the kinetic energy was removed for He atoms that have an initial velocity of 520 m/s. The hexapoles consist of permanent magnets, whereas the solenoids are produced from a single hollow copper capillary through which cooling liquid is passed. The solenoid design allows for excellent thermal properties, and enables the use of readily available and cheap electronics components to pulse high currents through the solenoids. The Zeeman decelerator demonstrated here is mechanically easy to build, can be operated with cost-effective electronics, and can run at repetition rates up to 10 Hz.

DOI
10.48550/arxiv.1702.04223

Related papers

Multistage Zeeman decelerator for molecular-scattering studies

Theo Cremers, Simon Chefdeville, Niek Janssen +4 more

We present a concept for a multistage Zeeman decelerator that is optimized particularly for applications in molecular beam scattering experiments. The decelerator consists of a series of alternating hexapoles and solenoids, that effectively decouple the transverse focusing and longitudinal deceleration properties of the decelerator. It can be operated in a deceleration and acceleration mode, as well as in a hybrid mode that makes it possible to guide a particle beam through the decelerator at constant speed. The deceleration features phase stability, with a relatively large six-dimensional phase-space acceptance. The separated focusing and deceleration elements result in an unequal partitioning of this acceptance between the longitudinal and transverse directions. This is ideal in scattering experiments, which typically benefit from a large longitudinal acceptance combined with narrow transverse distributions. We demonstrate the successful experimental implementation of this concept using a Zeeman decelerator consisting of an array of 25 hexapoles and 24 solenoids. The performance of the decelerator in acceleration, deceleration, and guiding modes is characterized using beams of metastable helium ($^{3}S$) atoms. Up to 60% of the kinetic energy was removed for He atoms that have an initial velocity of 520 m/s. The hexapoles consist of permanent magnets, whereas the solenoids are produced from a single hollow copper capillary through which cooling liquid is passed. The solenoid design allows for excellent thermal properties and enables the use of readily available and cheap electronics components to pulse high currents through the solenoids. The Zeeman decelerator demonstrated here is mechanically easy to build, can be operated with cost-effective electronics, and can run at repetition rates up to 10 Hz.

arXiv:1702.05477•Physical Review A•Apr 19, 2017•24 citations

Design and construction of a multistage Zeeman decelerator for crossed molecular beams scattering experiments

Theo Cremers, Niek Janssen, Edwin Sweers +1 more

Zeeman deceleration is a relatively new technique used to obtain full control over the velocity of paramagnetic atoms or molecules in a molecular beam. We present a detailed description of a multistage Zeeman decelerator that has recently become operational in our laboratory [Cremers et al., Phys. Rev. A 98, 033406 (2018)] and that is specifically optimized for crossed molecular beams scattering experiments. The decelerator consists of an alternating array of 100 solenoids and 100 permanent hexapoles to guide or decelerate beams of paramagnetic atoms or molecules. The Zeeman decelerator features a modular design that is mechanically easy to extend to arbitrary length and allows for solenoid and hexapole elements that are convenient to replace. The solenoids and associated electronics are efficiently water cooled and allow the Zeeman decelerator to operate at repetition rates exceeding 10 Hz. We characterize the performance of the decelerator using various beams of metastable rare gas atoms. Imaging of the atoms that exit the Zeeman decelerator reveals the transverse focusing properties of the hexapole array in the Zeeman decelerator.

arXiv:1901.02643•Review of Scientific Instruments•Jan 1, 2019•23 citations

Multistage Zeeman deceleration of atomic and molecular oxygen

Theo Cremers, Simon Chefdeville, Vikram Plomp +3 more

Multistage Zeeman deceleration is a technique used to reduce the velocity of neutral molecules with a magnetic-dipole moment. Here we present a Zeeman decelerator that consists of 100 solenoids and 100 magnetic hexapoles that is based on a short prototype design presented recently [Phys. Rev. A 95, 043415 (2017)]. The decelerator features a modular design with excellent thermal and vacuum properties and is robustly operated at a 10 Hz repetition rate. We use this decelerator to demonstrate the state-selective deceleration of atomic oxygen to final mean velocities in the range 500--125 m/s. We further characterize our decelerator with molecular oxygen, which, despite its heavier mass, is velocity tuned in the range 350--150 m/s. This corresponds to a maximum kinetic-energy reduction of 95% and 80% for atomic and molecular oxygen, respectively. The long multistage Zeeman decelerator presented here demonstrates that the concept of using alternating hexapoles and solenoids is truly phase stable. This Zeeman decelerator is ideally suited for applications in crossed-beam scattering experiments; the state-selected and velocity-controlled samples of O atoms and ${\mathrm{O}}_{2}$ molecules are particularly relevant for studies of inelastic and reactive processes.

arXiv:1805.07202•Physical Review A•Sep 6, 2018•18 citations

Multistage Zeeman deceleration of atoms and molecules

A. W. Wiederkehr

A modular multistage Zeeman decelerator consisting of an array of solenoids has been developed to control the velocity of cold, paramagnetic atoms and molecules in supersonic beams. The translational motion these atoms and molecules was manipulated with high precision by exploiting the interaction between their magnetic moments and timedependent inhomogeneous magnetic elds. Deceleration was achieved by pulsing high currents (up to 300 A) through the solenoids of the decelerator with pulse sequences calculated to preserve the phase-space density of the atomic and molecular samples while removing a preset amount of kinetic energy. For the operation of the multistage Zeeman decelerator, solenoids and electronic units were developed to generate strong magneticeld pulses (> 2 T) with rise and fall times of only a few microseconds. An accurate three-dimensional particle-trajectory simulation program has been developed to analyze the deceleration process and optimize its e ciency. This software was thoroughly tested by systematic comparison with experimental results and enabled, in combination with measurements, the complete characterization of the spatial and velocity distributions of the decelerated and trapped atoms for di erent sets of experimental conditions. The program was essential to achieve a complete interpretation of the dynamics of the deceleration process and to devise a strategy to e ciently load the decelerated atoms and molecules into magnetic quadrupole traps. In a rst experiment, hydrogen atoms seeded in a supersonic expansion of Kr have been decelerated from an initial velocity of 435 m/s to nal velocities as low as 107 m/s in a 12-stage Zeeman decelerator. The operation of the decelerator has been analyzed by comparing the results of numerical particle-trajectory simulations with those of independent measurements of the velocity distribution by ion time-ofight mass spectrometry following photoionization of the decelerated atoms. The velocity distribution of the decelerated atom cloud was found to have a half width at half maximum of 25± 12 m/s corresponding to a temperature of ∼ 40 mK. The phase stability of the multistage-Zeeman-deceleration process has been investigated by numerical particle-trajectory simulations and experimental measurements on deuterium atoms in a 24-stage Zeeman decelerator. A one-dimensional analytical model of the phase stability in a multistage Zeeman decelerator was adapted from a one-dimensional model of phase stability in a multistage Stark decelerator and compared with the results of oneand three-dimensional particle-trajectory simulations. The comparison, which included the analysis of the e ects of nite switch-on and switch-o times of the deceleration pulses, revealed that transverse e ects in the decelerator lead to a considerable reduction of the

•Jan 1, 2012•0 citations

Multistage Zeeman deceleration of metastable neon

A. W. Wiederkehr, M. Motsch, S. D. Hogan +5 more

A supersonic beam of metastable neon atoms has been decelerated by exploiting the interaction between the magnetic moment of the atoms and time-dependent inhomogeneous magnetic fields in a multistage Zeeman decelerator. Using 91 deceleration solenoids, the atoms were decelerated from an initial velocity of 580m/s to final velocities as low as 105m/s, corresponding to a removal of more than 95% of their initial kinetic energy. The phase-space distribution of the cold, decelerated atoms was characterized by time-of-flight and imaging measurements, from which a temperature of 10mK was obtained in the moving frame of the decelerated sample. In combination with particle-trajectory simulations, these measurements allowed the phase-space acceptance of the decelerator to be quantified. The degree of isotope separation that can be achieved by multistage Zeeman deceleration was also studied by performing experiments with pulse sequences generated for ²⁰Ne and ²²Ne. © 2011 American Institute of Physics.

•Dec 7, 2011•19 citations

A Moving-Trap Zeeman Decelerator

McArd, Lewis A., Arin Mizouri, Walker, Paul A. +4 more

We present a moving-trap Zeeman decelerator (MTZD) for use in molecular beam manipulation and magnetic-trapping experiments of paramagnetic atoms and molecules. The 0.49 m MTZD consists of a combination of a 2D magnetic quadrupole guide and deceleration coils, which together produce an array of 3D magnetic traps. The design is based on that of Trimeche et al. with significant modifications. The 2D quadrupole is driven by fast rising and falling square pulses of current (up to 700 A) of arbitrary lengths of time. The traps can be made to move at velocities from ca. 370 m/s down to zero, which is done by driving through the deceleration coils a sinusoidal current with frequencies ranging from zero to ca. 9 kHz and peak currents up to 1000 A. The trap velocity is proportional to the current frequency. The MTZD manipulates the velocities of molecular beams by traveling initially at the same velocity as the beam. 3D guiding is achieved with a constant current frequency and deceleration is achieved with a downward chirp of the current frequency at a rate corresponding to the desired deceleration. We explain the technical design and operation principles of the MTZD and we detail the custom power electronics that drive the 2D quadrupole guide and the decelerator coils. We present extensive Monte-Carlo trajectory simulations to demonstrate the properties of the MTZD and we conclude that decelerations should be kept below 30000 m/s/s to maintain a good 6D phase-space acceptance. In proof-of-principle experiments, with the deceleration coils operating with a reduced current in the range 100-200 A, we demonstrate the 3D guiding of a beam of metastable argon atoms at 373 m/s and deceleration at 25000 m/s/s from 342 m/s to 304 m/s. The deceleration corresponds to the removal of 21% of the kinetic energy of the beam.

arXiv:1807.10648•Jul 27, 2018•4 citations
We demonstrate the successful experimental implementation of a multi-stage Zeeman decelerator utilizing the new concept described in the accompanying paper. The decelerator consists of an array of 25 hexapoles and 24 solenoids. The performance of the decelerator in acceleration, deceleration and guiding modes is characterized using beams of metastable Helium (3S^3S3S) atoms. Up to 60% of the kinetic energy was removed for He atoms that have an initial velocity of 520 m/s. The hexapoles consist of permanent magnets, whereas the solenoids are produced from a single hollow copper capillary through which cooling liquid is passed. The solenoid design allows for excellent thermal properties, and enables the use of readily available and cheap electronics components to pulse high currents through the solenoids. The Zeeman decelerator demonstrated here is mechanically easy to build, can be operated with cost-effective electronics, and can run at repetition rates up to 10 Hz.
We present a concept for a multistage Zeeman decelerator that is optimized particularly for applications in molecular beam scattering experiments. The decelerator consists of a series of alternating hexapoles and solenoids, that effectively decouple the transverse focusing and longitudinal deceleration properties of the decelerator. It can be operated in a deceleration and acceleration mode, as well as in a hybrid mode that makes it possible to guide a particle beam through the decelerator at constant speed. The deceleration features phase stability, with a relatively large six-dimensional phase-space acceptance. The separated focusing and deceleration elements result in an unequal partitioning of this acceptance between the longitudinal and transverse directions. This is ideal in scattering experiments, which typically benefit from a large longitudinal acceptance combined with narrow transverse distributions. We demonstrate the successful experimental implementation of this concept using a Zeeman decelerator consisting of an array of 25 hexapoles and 24 solenoids. The performance of the decelerator in acceleration, deceleration, and guiding modes is characterized using beams of metastable helium (3S^{3}S3S) atoms. Up to 60% of the kinetic energy was removed for He atoms that have an initial velocity of 520 m/s. The hexapoles consist of permanent magnets, whereas the solenoids are produced from a single hollow copper capillary through which cooling liquid is passed. The solenoid design allows for excellent thermal properties and enables the use of readily available and cheap electronics components to pulse high currents through the solenoids. The Zeeman decelerator demonstrated here is mechanically easy to build, can be operated with cost-effective electronics, and can run at repetition rates up to 10 Hz.
Zeeman deceleration is a relatively new technique used to obtain full control over the velocity of paramagnetic atoms or molecules in a molecular beam. We present a detailed description of a multistage Zeeman decelerator that has recently become operational in our laboratory [Cremers et al., Phys. Rev. A 98, 033406 (2018)] and that is specifically optimized for crossed molecular beams scattering experiments. The decelerator consists of an alternating array of 100 solenoids and 100 permanent hexapoles to guide or decelerate beams of paramagnetic atoms or molecules. The Zeeman decelerator features a modular design that is mechanically easy to extend to arbitrary length and allows for solenoid and hexapole elements that are convenient to replace. The solenoids and associated electronics are efficiently water cooled and allow the Zeeman decelerator to operate at repetition rates exceeding 10 Hz. We characterize the performance of the decelerator using various beams of metastable rare gas atoms. Imaging of the atoms that exit the Zeeman decelerator reveals the transverse focusing properties of the hexapole array in the Zeeman decelerator.
Multistage Zeeman deceleration is a technique used to reduce the velocity of neutral molecules with a magnetic-dipole moment. Here we present a Zeeman decelerator that consists of 100 solenoids and 100 magnetic hexapoles that is based on a short prototype design presented recently [Phys. Rev. A 95, 043415 (2017)]. The decelerator features a modular design with excellent thermal and vacuum properties and is robustly operated at a 10 Hz repetition rate. We use this decelerator to demonstrate the state-selective deceleration of atomic oxygen to final mean velocities in the range 500--125 m/s. We further characterize our decelerator with molecular oxygen, which, despite its heavier mass, is velocity tuned in the range 350--150 m/s. This corresponds to a maximum kinetic-energy reduction of 95% and 80% for atomic and molecular oxygen, respectively. The long multistage Zeeman decelerator presented here demonstrates that the concept of using alternating hexapoles and solenoids is truly phase stable. This Zeeman decelerator is ideally suited for applications in crossed-beam scattering experiments; the state-selected and velocity-controlled samples of O atoms and O2{\mathrm{O}}_{2}O2​ molecules are particularly relevant for studies of inelastic and reactive processes.
A modular multistage Zeeman decelerator consisting of an array of solenoids has been developed to control the velocity of cold, paramagnetic atoms and molecules in supersonic beams. The translational motion these atoms and molecules was manipulated with high precision by exploiting the interaction between their magnetic moments and timedependent inhomogeneous magnetic elds. Deceleration was achieved by pulsing high currents (up to 300 A) through the solenoids of the decelerator with pulse sequences calculated to preserve the phase-space density of the atomic and molecular samples while removing a preset amount of kinetic energy. For the operation of the multistage Zeeman decelerator, solenoids and electronic units were developed to generate strong magneticeld pulses (> 2 T) with rise and fall times of only a few microseconds. An accurate three-dimensional particle-trajectory simulation program has been developed to analyze the deceleration process and optimize its e ciency. This software was thoroughly tested by systematic comparison with experimental results and enabled, in combination with measurements, the complete characterization of the spatial and velocity distributions of the decelerated and trapped atoms for di erent sets of experimental conditions. The program was essential to achieve a complete interpretation of the dynamics of the deceleration process and to devise a strategy to e ciently load the decelerated atoms and molecules into magnetic quadrupole traps. In a rst experiment, hydrogen atoms seeded in a supersonic expansion of Kr have been decelerated from an initial velocity of 435 m/s to nal velocities as low as 107 m/s in a 12-stage Zeeman decelerator. The operation of the decelerator has been analyzed by comparing the results of numerical particle-trajectory simulations with those of independent measurements of the velocity distribution by ion time-ofight mass spectrometry following photoionization of the decelerated atoms. The velocity distribution of the decelerated atom cloud was found to have a half width at half maximum of 25± 12 m/s corresponding to a temperature of ∼ 40 mK. The phase stability of the multistage-Zeeman-deceleration process has been investigated by numerical particle-trajectory simulations and experimental measurements on deuterium atoms in a 24-stage Zeeman decelerator. A one-dimensional analytical model of the phase stability in a multistage Zeeman decelerator was adapted from a one-dimensional model of phase stability in a multistage Stark decelerator and compared with the results of oneand three-dimensional particle-trajectory simulations. The comparison, which included the analysis of the e ects of nite switch-on and switch-o times of the deceleration pulses, revealed that transverse e ects in the decelerator lead to a considerable reduction of the
A supersonic beam of metastable neon atoms has been decelerated by exploiting the interaction between the magnetic moment of the atoms and time-dependent inhomogeneous magnetic fields in a multistage Zeeman decelerator. Using 91 deceleration solenoids, the atoms were decelerated from an initial velocity of 580m/s to final velocities as low as 105m/s, corresponding to a removal of more than 95% of their initial kinetic energy. The phase-space distribution of the cold, decelerated atoms was characterized by time-of-flight and imaging measurements, from which a temperature of 10mK was obtained in the moving frame of the decelerated sample. In combination with particle-trajectory simulations, these measurements allowed the phase-space acceptance of the decelerator to be quantified. The degree of isotope separation that can be achieved by multistage Zeeman deceleration was also studied by performing experiments with pulse sequences generated for ²⁰Ne and ²²Ne. © 2011 American Institute of Physics.
We present a moving-trap Zeeman decelerator (MTZD) for use in molecular beam manipulation and magnetic-trapping experiments of paramagnetic atoms and molecules. The 0.49 m MTZD consists of a combination of a 2D magnetic quadrupole guide and deceleration coils, which together produce an array of 3D magnetic traps. The design is based on that of Trimeche et al. with significant modifications. The 2D quadrupole is driven by fast rising and falling square pulses of current (up to 700 A) of arbitrary lengths of time. The traps can be made to move at velocities from ca. 370 m/s down to zero, which is done by driving through the deceleration coils a sinusoidal current with frequencies ranging from zero to ca. 9 kHz and peak currents up to 1000 A. The trap velocity is proportional to the current frequency. The MTZD manipulates the velocities of molecular beams by traveling initially at the same velocity as the beam. 3D guiding is achieved with a constant current frequency and deceleration is achieved with a downward chirp of the current frequency at a rate corresponding to the desired deceleration. We explain the technical design and operation principles of the MTZD and we detail the custom power electronics that drive the 2D quadrupole guide and the decelerator coils. We present extensive Monte-Carlo trajectory simulations to demonstrate the properties of the MTZD and we conclude that decelerations should be kept below 30000 m/s/s to maintain a good 6D phase-space acceptance. In proof-of-principle experiments, with the deceleration coils operating with a reduced current in the range 100-200 A, we demonstrate the 3D guiding of a beam of metastable argon atoms at 373 m/s and deceleration at 25000 m/s/s from 342 m/s to 304 m/s. The deceleration corresponds to the removal of 21% of the kinetic energy of the beam.