Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1701.08348 · Applied Physics Letters

Two-photon imaging assisted by a thin dynamic scattering layer

Peilong Hong

Published Sep 3, 2018• 11 citations
arXivHTMLPDF

Abstract

We propose a two-photon imaging scheme with a thin dynamic scattering layer as the crucial imaging element. The constructive two-photon interference for direct imaging is built when the object is properly illuminated by an entangled two-photon source. We show that the proposed imaging scheme can be used for imaging an amplitude object with incoherent two-photon illumination, and the resolution reaches Heisenberg limit. Besides, the imaging for a phase object can also be achieved in the proposed imaging scheme with coherent two-photon illumination.

DOI
10.1063/1.5042504

Related papers

Heisenberg-resolution imaging through a phase-controlled screen

Peilong Hong, Guoquan Zhang

We propose a N-photon imaging scheme with the resolution reaching the fundamental Heisenberg limit. The key imaging element is a phase-controlled screen which introduces synchronous-position N-photon interference, giving rise to enhanced resolution that exceeds the well-known Rayleigh resolution limit by a factor of N. In the standard wide-field illumination situation, our imaging scheme requires an entangled source to illuminate the object. Besides, we show that classical light is also applicable to realize this Heisenberg-resolution imaging if a scanning-focused-beam illumination is used. Our N-photon imaging scheme is practically realizable by using current well-developed technology.

Optics Express•Sep 11, 2017•12 citations

Entangled-Photon Imaging of a Pure Phase Object

Ayman F. Abouraddy, Patrick R. Stone, Alexander V. Sergienko +2 more

We demonstrate experimentally and theoretically that a coherent image of a pure phase object [implemented by a microelectromechanical system (MEMS) micromirror array] may be obtained by use of a spatially incoherent illumination beam. This is accomplished by employing a two-beam source of entangled photons generated by spontaneous parametric down-conversion. One of the beams probes the phase object while the other is scanned. Though each of the beams is, in and of itself, spatially incoherent, the pair of beams exhibits higher-order interbeam coherence.

arXiv:quant-ph/0311147•Physical Review Letters•Nov 17, 2004•109 citations

Experimental observation of sub-Rayleigh quantum imaging with a two-photon entangled source

De-Qin Xu, Xin-Bing Song, Hong-Guo Li +4 more

It has been theoretically predicted that N-photon quantum imaging can realize either an N-fold resolution improvement (Heisenberg-like scaling) or a N-fold resolution improvement (standard quantum limit) beyond the Rayleigh diffraction bound, over classical imaging. Here, we report the experimental study on spatial sub-Rayleigh quantum imaging using a two-photon entangled source. Two experimental schemes are proposed and performed. In a Fraunhofer diffraction scheme with a lens, two-photon Airy disk pattern is observed with subwavelength diffraction property. In a lens imaging apparatus, however, two-photon sub-Rayleigh imaging for an object is realized with super-resolution property. The experimental results agree with the theoretical prediction in the two-photon quantum imaging regime.

Applied Physics Letters•Apr 27, 2015•38 citations

Subwavelength-resolution Imaging with Undetected Photons using Thin Sources of Photon Pairs

Elkin A. Santos, Sina Saravi, Thomas Pertsch +1 more

We present an imaging scheme with undetected photons that overcomes the diffraction limit by transferring near-field information at the wavelength that illuminates the object to the far-field of its paired wavelength generated in a thin photon-pair source.

Quantum Information and Measurement (QIM)•Jan 1, 2021•0 citations

Fundamental resolution limit of quantum imaging with undetected photons

Andres Vega, Elkin A. Santos, Jorge Fuenzalida +5 more

Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.

arXiv:2203.06106•Physical Review Research•Sep 30, 2022•28 citations

Resolution in Two-Photon Imaging: A Local Manifestation of Entanglement

Thomas Gregory, Ermes Toninelli, Paul‐Antoine Moreau +6 more

High Resolution Image Download MS PowerPoint Slide The resolution of a classical imaging system is limited by diffraction. This limit can be overcome, for example, by implementing various forms of localization microscopy in which the center of a fluorescence distribution is estimated to an accuracy scaling with the square root of the number of detected photons, N . In quantum imaging the object can be illuminated using correlated photon-pairs, leading early work to suggest that a 2 improvement could be obtained as a result of averaging the position of N = 2 events. However, similar to quantum lithography, which relies upon quantum illumination using entangled photon-pairs and two-photon absorption, the minimum resolvable feature size is reduced by a factor of 2, not just 2 . Quantum imaging schemes can also lead to a factor of 2 improvement. By using a similar source of correlated photon-pairs to illuminate an object, a single-photon sensitive camera to detect the photon-pairs, and an image processing algorithm to record and sum the bisector positions of the transmitted photon-pairs, we realize a similar factor of ×2 improvement in image resolution, surpassing that of most earlier quantum imaging work.

ACS Photonics•Sep 27, 2025•3 citations
We propose a two-photon imaging scheme with a thin dynamic scattering layer as the crucial imaging element. The constructive two-photon interference for direct imaging is built when the object is properly illuminated by an entangled two-photon source. We show that the proposed imaging scheme can be used for imaging an amplitude object with incoherent two-photon illumination, and the resolution reaches Heisenberg limit. Besides, the imaging for a phase object can also be achieved in the proposed imaging scheme with coherent two-photon illumination.
We propose a N-photon imaging scheme with the resolution reaching the fundamental Heisenberg limit. The key imaging element is a phase-controlled screen which introduces synchronous-position N-photon interference, giving rise to enhanced resolution that exceeds the well-known Rayleigh resolution limit by a factor of N. In the standard wide-field illumination situation, our imaging scheme requires an entangled source to illuminate the object. Besides, we show that classical light is also applicable to realize this Heisenberg-resolution imaging if a scanning-focused-beam illumination is used. Our N-photon imaging scheme is practically realizable by using current well-developed technology.
We demonstrate experimentally and theoretically that a coherent image of a pure phase object [implemented by a microelectromechanical system (MEMS) micromirror array] may be obtained by use of a spatially incoherent illumination beam. This is accomplished by employing a two-beam source of entangled photons generated by spontaneous parametric down-conversion. One of the beams probes the phase object while the other is scanned. Though each of the beams is, in and of itself, spatially incoherent, the pair of beams exhibits higher-order interbeam coherence.
It has been theoretically predicted that N-photon quantum imaging can realize either an N-fold resolution improvement (Heisenberg-like scaling) or a N-fold resolution improvement (standard quantum limit) beyond the Rayleigh diffraction bound, over classical imaging. Here, we report the experimental study on spatial sub-Rayleigh quantum imaging using a two-photon entangled source. Two experimental schemes are proposed and performed. In a Fraunhofer diffraction scheme with a lens, two-photon Airy disk pattern is observed with subwavelength diffraction property. In a lens imaging apparatus, however, two-photon sub-Rayleigh imaging for an object is realized with super-resolution property. The experimental results agree with the theoretical prediction in the two-photon quantum imaging regime.
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.
High Resolution Image Download MS PowerPoint Slide The resolution of a classical imaging system is limited by diffraction. This limit can be overcome, for example, by implementing various forms of localization microscopy in which the center of a fluorescence distribution is estimated to an accuracy scaling with the square root of the number of detected photons, N . In quantum imaging the object can be illuminated using correlated photon-pairs, leading early work to suggest that a 2 improvement could be obtained as a result of averaging the position of N = 2 events. However, similar to quantum lithography, which relies upon quantum illumination using entangled photon-pairs and two-photon absorption, the minimum resolvable feature size is reduced by a factor of 2, not just 2 . Quantum imaging schemes can also lead to a factor of 2 improvement. By using a similar source of correlated photon-pairs to illuminate an object, a single-photon sensitive camera to detect the photon-pairs, and an image processing algorithm to record and sum the bisector positions of the transmitted photon-pairs, we realize a similar factor of ×2 improvement in image resolution, surpassing that of most earlier quantum imaging work.