arXiv:1608.07915 · Physical Review A

Indirect measurement of three-photon correlation in nonclassical light sources

Byoung-moo Ann, Younghoon Song, Junki Kim, Daeho Yang, Kyungwon An

Published Jun 9, 2016• 2 citations
arXivHTMLPDF

Abstract

We observe the three-photon correlation in nonclassical light sources by using an indirect measurement scheme based on the dead-time effect of photon-counting detectors. We first develop a general theory which enables us to extract the three-photon correlation from the two-photon correlation of an arbitrary light source measured with detectors with finite dead times. We then confirm the validity of our measurement scheme in experiments done with a cavity-QED microlaser operating with a large intracavity mean photon number exhibiting both sub- and super-Poissonian photon statistics. The experimental results are in good agreement with the theoretical expectation. Our measurement scheme provides an alternative approach for $N$-photon correlation measurement employing $(N\ensuremath{-}1)$ detectors and thus a reduced measurement time for a given signal-to-noise ratio, compared to the usual scheme requiring $N$ detectors.

DOI
10.1103/physreva.93.063816

Related papers

Photon counting statistics with imperfect detectors

Aleksei Reutov, Сыч Денис Васильевич

Abstract Measurement of photon statistics is an important tool for the verification of quantum properties of light. Due to the various imperfections of real single photon detectors, the observed statistics of photon counts deviates from the underlying statistics of photons. Here we analyze statistical properties of coherent states, and investigate a connection between Poissonian distribution of photons and sub-Poissonian distribution of photon counts due to the detector dead-time corrections. We derive a functional dependence between the mean number of photons and the mean number of photon counts, as well as connection between higher-order statistical moments, for the pulsed or continuous wave coherent light sources, and confirm the results by numerical simulations.

Journal of Physics Conference Series•Dec 1, 2021•0 citations

Experimental observation of nonclassical effects in a single detection rate

Aephraim M. Steinberg

Summary form only given. In any optical system, quantum and classical theory yield identical predictions for the mean intensity. The quantum mechanical predictions diverge from the classical theory only for higher order correlations. For this reason, typical quantum-interference experiments are performed by measuring coincidence rates between two or more detectors. The usual approximation, following Glauber, is that a single-photon counter fires at a rate proportional to the intensity, or number of incident photons per unit time. This approximation is so good and so entrenched that one routinely assumes that all singles-detection rates are insensitive to quantum effects. However, if one of these detectors fires, it cannot fire again for a characteristic time, called the dead-time. This characteristic of the detectors makes them highly nonlinear over times shorter than the dead-time, and thus sensitive to the higher order intensity correlations. In other words the detector has a different response for two photons arriving at different times, than for two photons arriving at the same time. We use the process of spontaneous parametric-downconversion (SPDC) to create correlated photon-pairs and send them through a polarization-based Hong-Ou-Mander interferometer. This quantum interferometer allows us to change the photon statistics without changing the intensity of the beams.

Quantum Electronics and Laser Science Conference•May 12, 2000•0 citations

Measuring the absolute photodetection efficiency using photon number correlations

Michael Lindenthal, Johannes Kofler

We present two methods for determining the absolute detection efficiency of photon-counting detectors directly from their singles rates under illumination from a nonclassical light source. One method is based on a continuous variable analog to coincidence counting in discrete photon experiments, but it does not actually rely on high detector time resolutions. The second method is based on difference detection, which is a typical detection scheme in continuous variable quantum optics experiments. Since no coincidence detection is required with either method, they are useful for detection efficiency measurements of photodetectors with detector time resolutions far too low to resolve coincidence events.

arXiv:quant-ph/0606041•Applied Optics•Aug 20, 2006•10 citations

Reduction of quantum noise in transmittance estimation using photon-correlated beams

Majeed M. Hayat, Adel Joobeur, Bahaa E. A. Saleh

The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.

Journal of the Optical Society of America A•Feb 1, 1999•28 citations

Spectral and Correlation Properties of Two-Photon Light

Maria V. Chekhova

Although light quanta were known since the works by Planck and Einstein, for several decades after these works, there was no need to treat light quantum mechanically, and all experiments could be well explained using the quantum description of matter and classical description of light (the semiclassical approach). The situation changed with the development of sources of so-called nonclassical light, i.e., light whose properties cannot be understood in the framework of the semiclassical approach. Two simple examples can be given here. The first one is the suppression of shot noise in optical detectors. Shot noise, i.e., fluctuations of photocurrent scaling as the square root of the photocurrent mean value, can be, in principle, attributed to the discrete nature of the charge generated by the detector. At the same time, the effect of shot-noise suppression, which is observed with certain light sources (squeezed light) is clearly related to the statistics of light, and quantum mechanics is completely necessary for its description. Another example, which brings us closer to the subject of the present paper, is two-photon light. This type of light contains only pairs of photons (often called biphotons), and hence, a pair of properly aligned photon-counting detectors registering two-photon light, in an ideal case, will produce only simultaneous photocounts. This behavior, again, can only be explained in terms of a quantum-mechanical description for the light.

SPIE eBooks•Mar 16, 2010•0 citations

Correlation measurements in cavity QED: detuning effects

G. T. Foster, S. L. Mielke, Luis A. Orozco

Summary form only given. The second-order correlation function of the intensity is a measurement of the intensity fluctuations and their enhancement or suppression relative to an ideal laser field. It is a sensitive probe of the dynamic processes involved in producing the light. We have measured the correlation function of the photons escaping from a cavity QED system consisting of a high-finesse interferometer traversed by an atomic beam of optically pumped Rb atoms. We observe nonclassical correlations, exhibiting antibunching and sub-Poissonian statistics.

Conference on Lasers and Electro-Optics•Nov 27, 2002•0 citations
We observe the three-photon correlation in nonclassical light sources by using an indirect measurement scheme based on the dead-time effect of photon-counting detectors. We first develop a general theory which enables us to extract the three-photon correlation from the two-photon correlation of an arbitrary light source measured with detectors with finite dead times. We then confirm the validity of our measurement scheme in experiments done with a cavity-QED microlaser operating with a large intracavity mean photon number exhibiting both sub- and super-Poissonian photon statistics. The experimental results are in good agreement with the theoretical expectation. Our measurement scheme provides an alternative approach for NNN-photon correlation measurement employing (N\ensuremath−1)(N\ensuremath{-}1)(N\ensuremath−1) detectors and thus a reduced measurement time for a given signal-to-noise ratio, compared to the usual scheme requiring NNN detectors.
Abstract Measurement of photon statistics is an important tool for the verification of quantum properties of light. Due to the various imperfections of real single photon detectors, the observed statistics of photon counts deviates from the underlying statistics of photons. Here we analyze statistical properties of coherent states, and investigate a connection between Poissonian distribution of photons and sub-Poissonian distribution of photon counts due to the detector dead-time corrections. We derive a functional dependence between the mean number of photons and the mean number of photon counts, as well as connection between higher-order statistical moments, for the pulsed or continuous wave coherent light sources, and confirm the results by numerical simulations.
Summary form only given. In any optical system, quantum and classical theory yield identical predictions for the mean intensity. The quantum mechanical predictions diverge from the classical theory only for higher order correlations. For this reason, typical quantum-interference experiments are performed by measuring coincidence rates between two or more detectors. The usual approximation, following Glauber, is that a single-photon counter fires at a rate proportional to the intensity, or number of incident photons per unit time. This approximation is so good and so entrenched that one routinely assumes that all singles-detection rates are insensitive to quantum effects. However, if one of these detectors fires, it cannot fire again for a characteristic time, called the dead-time. This characteristic of the detectors makes them highly nonlinear over times shorter than the dead-time, and thus sensitive to the higher order intensity correlations. In other words the detector has a different response for two photons arriving at different times, than for two photons arriving at the same time. We use the process of spontaneous parametric-downconversion (SPDC) to create correlated photon-pairs and send them through a polarization-based Hong-Ou-Mander interferometer. This quantum interferometer allows us to change the photon statistics without changing the intensity of the beams.
We present two methods for determining the absolute detection efficiency of photon-counting detectors directly from their singles rates under illumination from a nonclassical light source. One method is based on a continuous variable analog to coincidence counting in discrete photon experiments, but it does not actually rely on high detector time resolutions. The second method is based on difference detection, which is a typical detection scheme in continuous variable quantum optics experiments. Since no coincidence detection is required with either method, they are useful for detection efficiency measurements of photodetectors with detector time resolutions far too low to resolve coincidence events.
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
Although light quanta were known since the works by Planck and Einstein, for several decades after these works, there was no need to treat light quantum mechanically, and all experiments could be well explained using the quantum description of matter and classical description of light (the semiclassical approach). The situation changed with the development of sources of so-called nonclassical light, i.e., light whose properties cannot be understood in the framework of the semiclassical approach. Two simple examples can be given here. The first one is the suppression of shot noise in optical detectors. Shot noise, i.e., fluctuations of photocurrent scaling as the square root of the photocurrent mean value, can be, in principle, attributed to the discrete nature of the charge generated by the detector. At the same time, the effect of shot-noise suppression, which is observed with certain light sources (squeezed light) is clearly related to the statistics of light, and quantum mechanics is completely necessary for its description. Another example, which brings us closer to the subject of the present paper, is two-photon light. This type of light contains only pairs of photons (often called biphotons), and hence, a pair of properly aligned photon-counting detectors registering two-photon light, in an ideal case, will produce only simultaneous photocounts. This behavior, again, can only be explained in terms of a quantum-mechanical description for the light.
Summary form only given. The second-order correlation function of the intensity is a measurement of the intensity fluctuations and their enhancement or suppression relative to an ideal laser field. It is a sensitive probe of the dynamic processes involved in producing the light. We have measured the correlation function of the photons escaping from a cavity QED system consisting of a high-finesse interferometer traversed by an atomic beam of optically pumped Rb atoms. We observe nonclassical correlations, exhibiting antibunching and sub-Poissonian statistics.