Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1604.07367 · Physical Review Letters

Ultimate Precision Bound of Quantum and Subwavelength Imaging

Cosmo Lupo, Stefano Pirandola

Published Nov 4, 2016• 165 citations
arXivHTMLPDF

Abstract

We determine the ultimate potential of quantum imaging for boosting the resolution of a far-field, diffraction-limited, linear imaging device within the paraxial approximation. First, we show that the problem of estimating the separation between two pointlike sources is equivalent to the estimation of the loss parameters of two lossy bosonic channels, i.e., the transmissivities of two beam splitters. Using this representation, we establish the ultimate precision bound for resolving two pointlike sources in an arbitrary quantum state, with a simple formula for the specific case of two thermal sources. We find that the precision bound scales with the number of collected photons according to the standard quantum limit. Then, we determine the sources whose separation can be estimated optimally, finding that quantum-correlated sources (entangled or discordant) can be superresolved at the sub-Rayleigh scale. Our results apply to a variety of imaging setups, from astronomical observation to microscopy, exploiting quantum detection as well as source engineering.

DOI
10.1103/physrevlett.117.190802

Related papers

Quantum-limited localization and resolution in three dimensions

Ben Wang, Liang Xu, Jun-chi Li +1 more

As a method to extract information from optical systems, imaging can be viewed as a parameter estimation problem. The fundamental precision in locating one emitter or estimating the separation between two incoherent emitters is bounded below by the multiparameter quantum Cramér-Rao bound (QCRB). Multiparameter QCRB gives an intrinsic bound in parameter estimation. We determine the ultimate potential of quantum-limited imaging for improving the resolution of a far-field, diffraction-limited optical field within the paraxial approximation. We show that the quantum Fisher information matrix (QFIm) in about one emitter’s position is independent on its true value. We calculate the QFIm of two unequal-brightness emitters’ relative positions and intensities; the results show that only when the relative intensity and centroids of two-point sources, including longitudinal and transverse directions, are known exactly, the separation in different directions can be estimated simultaneously with finite precision. Our results give the upper bounds on certain far-field imaging technology and will find wide use in applications from microscopy to astrometry.

arXiv:2012.05089•Photonics Research•Jun 9, 2021•19 citations

Far-Field Superresolution of Thermal Electromagnetic Sources at the Quantum Limit

Ranjith Nair, Mankei Tsang

We obtain the ultimate quantum limit for estimating the transverse separation of two thermal point sources using a given imaging system with limited spatial bandwidth. We show via the quantum Cramér-Rao bound that, contrary to the Rayleigh limit in conventional direct imaging, quantum mechanics does not mandate any loss of precision in estimating even deep sub-Rayleigh separations. We propose two coherent measurement techniques, easily implementable using current linear-optics technology, that approach the quantum limit over an arbitrarily large range of separations. Our bound is valid for arbitrary source strengths, all regions of the electromagnetic spectrum, and for any imaging system with an inversion-symmetric point-spread function. The measurement schemes can be applied to microscopy, optical sensing, and astrometry at all wavelengths.

arXiv:1604.00937•Physical Review Letters•Nov 4, 2016•188 citations

Towards the quantum limit for two bright-source separation estimation

Giacomo Sorelli, Clémentine Rouvière, Ilya Karuseichyk +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works, analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. However, most previous works have either consider low-intensity, or thermal sources. To broaden the applicability of this approach, it is important to extend these results to more general light sources. To this goal, we will present an analytical expression for the Quantum Fisher Information, determining the ultimate resolution limit, for the separation between two sources in an arbitrary Gaussian state. Applying this result to different quantum states, we can shine some light on some relevant questions. We can for example explore the role of partial coherence considering displaced and correlated thermal states, or investigate the importance of quantum correlations by considering squeezed light. In addition to the ultimate quantum limit, we will discuss a simple estimation technique, requiring access only to the mean value of a linear combination of demultiplexed intensity measurements, which is often sufficient to saturate these limits, and can easily be adapted to incorporate the most common noise sources. Finally, we will present our experimental setup that allows for the generation of the images of two sources with different photon statistics, as well as for spatial mode demultiplexing and we will discuss the first practical implementations if the above mentioned estimation techniques.

SPIE Quantum Technologies•Jun 3, 2022•0 citations

Superresolution in interferometric imaging of thermal sources of arbitrary strength

Yunkai Wang, Yujie Zhang, Virginia O. Lorenz

It has been shown through quantum estimation theory that Rayleigh’s limit can be avoided for single-lens imaging, referred to as superresolution. The quantum estimation approach has recently been used to show superresolution is also possible for imaging based on interferometer arrays in the weak source limit. Following this line of discussion, we consider the resolution limit of estimating the separation between two point sources of arbitrary strength using interferometer arrays. By carefully designing the measurement, we find it is possible to overcome the well-known resolution limit of interferometer arrays as determined by the longest baseline. We construct an optimal measurement to achieve superresolution using linear beam-splitters and photon-number resolved detection.

Optical and Quantum Sensing and Precision Metrology II•Mar 3, 2022•0 citations

Sub-wavelength quantum imaging

Cosmo Lupo, Zixin Huang, Pieter Kpk

The resolution limit of standard imaging techniques is expressed by the Rayleigh criterion, which states that two point-like sources are difficult to resolve if their transverse separation is smaller that the Rayleigh length. While the criterion is useful in the case of direct detection imaging, other measurement techniques may not be subject to this limitation. Here we consider the use of imaging to estimate the distance between two incoherent point sources. In this framework, the Rayleigh criterion manifests itself through the so-called Rayleigh curse. The latter expresses the fact that the statistical error in the estimation increases for sub-wavelength separation. Here we show that, in the regime of weak signals, a structured measurement obtained by concatenating a linear interferometer with on-off photo-detection is immune to the Rayleigh curse. In this way we clarify the relation between imaging and interferometry, and establish the optimality of linear interferometry for an arbitrary number of incoherent sources.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Towards Superresolution Surface Metrology: Quantum Estimation of Angular and Axial Separations

Carmine Napoli, Samanta Piano, Richard Leach +2 more

We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.

arXiv:1805.04116•Physical Review Letters•Apr 12, 2019•81 citations
We determine the ultimate potential of quantum imaging for boosting the resolution of a far-field, diffraction-limited, linear imaging device within the paraxial approximation. First, we show that the problem of estimating the separation between two pointlike sources is equivalent to the estimation of the loss parameters of two lossy bosonic channels, i.e., the transmissivities of two beam splitters. Using this representation, we establish the ultimate precision bound for resolving two pointlike sources in an arbitrary quantum state, with a simple formula for the specific case of two thermal sources. We find that the precision bound scales with the number of collected photons according to the standard quantum limit. Then, we determine the sources whose separation can be estimated optimally, finding that quantum-correlated sources (entangled or discordant) can be superresolved at the sub-Rayleigh scale. Our results apply to a variety of imaging setups, from astronomical observation to microscopy, exploiting quantum detection as well as source engineering.
As a method to extract information from optical systems, imaging can be viewed as a parameter estimation problem. The fundamental precision in locating one emitter or estimating the separation between two incoherent emitters is bounded below by the multiparameter quantum Cramér-Rao bound (QCRB). Multiparameter QCRB gives an intrinsic bound in parameter estimation. We determine the ultimate potential of quantum-limited imaging for improving the resolution of a far-field, diffraction-limited optical field within the paraxial approximation. We show that the quantum Fisher information matrix (QFIm) in about one emitter’s position is independent on its true value. We calculate the QFIm of two unequal-brightness emitters’ relative positions and intensities; the results show that only when the relative intensity and centroids of two-point sources, including longitudinal and transverse directions, are known exactly, the separation in different directions can be estimated simultaneously with finite precision. Our results give the upper bounds on certain far-field imaging technology and will find wide use in applications from microscopy to astrometry.
We obtain the ultimate quantum limit for estimating the transverse separation of two thermal point sources using a given imaging system with limited spatial bandwidth. We show via the quantum Cramér-Rao bound that, contrary to the Rayleigh limit in conventional direct imaging, quantum mechanics does not mandate any loss of precision in estimating even deep sub-Rayleigh separations. We propose two coherent measurement techniques, easily implementable using current linear-optics technology, that approach the quantum limit over an arbitrarily large range of separations. Our bound is valid for arbitrary source strengths, all regions of the electromagnetic spectrum, and for any imaging system with an inversion-symmetric point-spread function. The measurement schemes can be applied to microscopy, optical sensing, and astrometry at all wavelengths.
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works, analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. However, most previous works have either consider low-intensity, or thermal sources. To broaden the applicability of this approach, it is important to extend these results to more general light sources. To this goal, we will present an analytical expression for the Quantum Fisher Information, determining the ultimate resolution limit, for the separation between two sources in an arbitrary Gaussian state. Applying this result to different quantum states, we can shine some light on some relevant questions. We can for example explore the role of partial coherence considering displaced and correlated thermal states, or investigate the importance of quantum correlations by considering squeezed light. In addition to the ultimate quantum limit, we will discuss a simple estimation technique, requiring access only to the mean value of a linear combination of demultiplexed intensity measurements, which is often sufficient to saturate these limits, and can easily be adapted to incorporate the most common noise sources. Finally, we will present our experimental setup that allows for the generation of the images of two sources with different photon statistics, as well as for spatial mode demultiplexing and we will discuss the first practical implementations if the above mentioned estimation techniques.
It has been shown through quantum estimation theory that Rayleigh’s limit can be avoided for single-lens imaging, referred to as superresolution. The quantum estimation approach has recently been used to show superresolution is also possible for imaging based on interferometer arrays in the weak source limit. Following this line of discussion, we consider the resolution limit of estimating the separation between two point sources of arbitrary strength using interferometer arrays. By carefully designing the measurement, we find it is possible to overcome the well-known resolution limit of interferometer arrays as determined by the longest baseline. We construct an optimal measurement to achieve superresolution using linear beam-splitters and photon-number resolved detection.
The resolution limit of standard imaging techniques is expressed by the Rayleigh criterion, which states that two point-like sources are difficult to resolve if their transverse separation is smaller that the Rayleigh length. While the criterion is useful in the case of direct detection imaging, other measurement techniques may not be subject to this limitation. Here we consider the use of imaging to estimate the distance between two incoherent point sources. In this framework, the Rayleigh criterion manifests itself through the so-called Rayleigh curse. The latter expresses the fact that the statistical error in the estimation increases for sub-wavelength separation. Here we show that, in the regime of weak signals, a structured measurement obtained by concatenating a linear interferometer with on-off photo-detection is immune to the Rayleigh curse. In this way we clarify the relation between imaging and interferometry, and establish the optimality of linear interferometry for an arbitrary number of incoherent sources.
We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.