arXiv:1604.02593 · Journal of Low Temperature Physics

AC Bias Characterization of Low Noise Bolometers for SAFARI Using an Open-Loop Frequency Domain SQUID-based Multiplexer Operating Between 1 and 5 MHz

L. Gottardi, M. Bruijn, J.-R. Gao, R. den Hartog, R. Hijmering, H. Hoevers, P. Khosropanah, P. de Korte, Jan van der Kuur, M. Lindeman, M. Ridder

Published Jan 31, 2012• 7 citations
arXivHTMLPDF

Abstract

SRON is developing the Frequency Domain Multiplexing (FDM) read-out and the ultra low NEP TES bolometers array for the infra-red spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (<1 fW) and low noise ( $\mathrm{NEP}\sim 10^{-19}~\mathrm{W}/\sqrt{\mathrm{Hz}}$ ) in the TES bolometers. We conclude the paper by comparing the performance of a $4\times 10^{-19}~\mathrm{W}/\sqrt{\mathrm{Hz}}$ TES bolometer measured under DC and AC bias.

DOI
10.1007/s10909-012-0559-x

Related papers

Nearly Quantum Limited Two-Stage SQUID Amplifiers for the Frequency Domain Multiplexing of TES Based X-ray and Infrared Detectors

Luciano G. Gottardi, M. Kiviranta, Jan van der Kuur +3 more

The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.

IEEE Transactions on Applied Superconductivity•Nov 10, 2014•14 citations

Frequency division multiplexing readout of 60 low-noise transition-edge sensor bolometers

Qian Wang, P. Khosropanah, Jan van der Kuur +8 more

We demonstrate multiplexing readout of 60 transition edge sensor (TES) bolometers operating at 90 mK using a frequency division multiplexing readout chain with bias frequencies ranging from 1 to 3.5 MHz and with a typical frequency spacing of 32 kHz. The readout chain starts with a two-stage SQUID amplifier and has a noise level of 9.5 pA/Hz. We compare current–voltage curves and noise spectra of TESs measured in a single-pixel mode and in a multiplexing mode. We also map the noise equivalent power (NEP) and the saturation power of the bolometers in both modes, where there are 43 pixels that do not show more than 10% difference in NEP and 5% in saturation power when measured in single pixel and multiplex modes. We have read out a TES with an NEP of 0.45 aW/Hz in the multiplexing-mode, which demonstrates the capability of reading out ultra-low noise TES bolometer arrays for space applications.

Applied Physics Letters•Nov 1, 2021•4 citations

Weak-link phenomena in AC-biased transition edge sensors

Luciano G. Gottardi, Hiroki Akamatsu, M. P. Bruijn +9 more

It has been recently demonstrated that superconducting transition edge-sensors behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for transition-edge sensors (TES)-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a frequency domain multiplexer based on a linearised two-stage SQUID amplifier and high-Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark noise equivalent power of 3.2 \\times 10 -19 W/\\sqrt{Hz} developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.

•Jan 1, 2014•19 citations

AC voltage-biased superconducting bolometer for a frequency-domain SQUID multiplexer

Jaewon Yoon, John L. Clarke, Jan M. Gildemeister +2 more

We demonstrate that a voltage-biased superconducting bolometer (VSB), read out with superconducting quantum interference device (SQUID), can be biased with a sinusoidal voltage. We show that the load curves taken with AC- and DC-bias are nearly identical indicating that there is no identifiable degradation in the performance of the bolometer due to the AC bias. We discuss the use of a frequency-domain SQUID multiplexer with an array of VSB's that are AC-biased.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•3 citations

Frequency-domain multiplexing for large-scale bolometer arrays

Trevor M. Lanting, Hsiao-Mei Cho, John L. Clarke +5 more

We describe the development of a frequency-domain multiplexer (MUX) to read out arrays of superconducting transition-edge sensors (TES). Fabrication of large-format arrays of these sensors is becoming practical; however, reading out each sensor in the array is a major instrumental challenge that is possibly solved by frequency-domain multiplexing. Each sensor is AC biased at a different frequency, ranging from 380 kHz to 1 MHz. The sensor signal amplitude-modulates its respective AC bias frequency. An LC filter associated with each sensor suppresses Johnson noise from the other sensors. The signals are combined at a current summing node and measured by a single superconducting quantum interference device (SQUID). The individual signals from each sensor are then lock-in detected by room temperature electronics. Test chips with fully lithographed LC filters for up to 32 channels have been designed and fabricated. The capacitance and inductance values have been measured and are close to the design goals. We discuss the basic principles of frequency-domain multiplexing, the design and testing of the test chips, and the implementation of a practical system.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 1, 2003•16 citations

Frequency-Domain SQUID Multiplexing of Transition-Edge Sensors

Trevor M. Lanting, Hsiao-Mei Cho, John L. Clarke +7 more

We describe our frequency-domain readout multiplexer for transition-edge sensor (TES) bolometers and present measurements of an eight-channel multiplexer. Each sensor is biased with a sinusoidal bias at a distinct frequency. As the sensor absorbs power, it amplitude-modulates its sinusoidal bias. Sensor currents are summed and measured with a single superconducting quantum interference device (SQUID) array. The SQUID array consists of 100 dc-SQUID's in series and is operated with shunt feedback electronics which have a slew rate of 1.210/sup 7/ /spl Phi//sub 0//s. A tuned filter consisting of an inductor and capacitor are placed in series with each sensor to both limit the bandwidth of the Nyquist noise from each sensor and to allow us to bias all multiplexed sensors with a common wire. We place an upper limit on crosstalk between adjacent channels of 0.004, well below our design requirements. Demodulated noise spectra from multiplexed sensors show the expected white noise levels at frequencies above 200 mHz.

IEEE Transactions on Applied Superconductivity•Jun 1, 2005•2 citations
SRON is developing the Frequency Domain Multiplexing (FDM) read-out and the ultra low NEP TES bolometers array for the infra-red spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (<1 fW) and low noise ( NEP∼10−19 W/Hz\mathrm{NEP}\sim 10^{-19}~\mathrm{W}/\sqrt{\mathrm{Hz}}NEP∼10−19 W/Hz​ ) in the TES bolometers. We conclude the paper by comparing the performance of a 4×10−19 W/Hz4\times 10^{-19}~\mathrm{W}/\sqrt{\mathrm{Hz}}4×10−19 W/Hz​ TES bolometer measured under DC and AC bias.
The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.
We demonstrate multiplexing readout of 60 transition edge sensor (TES) bolometers operating at 90 mK using a frequency division multiplexing readout chain with bias frequencies ranging from 1 to 3.5 MHz and with a typical frequency spacing of 32 kHz. The readout chain starts with a two-stage SQUID amplifier and has a noise level of 9.5 pA/Hz. We compare current–voltage curves and noise spectra of TESs measured in a single-pixel mode and in a multiplexing mode. We also map the noise equivalent power (NEP) and the saturation power of the bolometers in both modes, where there are 43 pixels that do not show more than 10% difference in NEP and 5% in saturation power when measured in single pixel and multiplex modes. We have read out a TES with an NEP of 0.45 aW/Hz in the multiplexing-mode, which demonstrates the capability of reading out ultra-low noise TES bolometer arrays for space applications.
It has been recently demonstrated that superconducting transition edge-sensors behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for transition-edge sensors (TES)-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a frequency domain multiplexer based on a linearised two-stage SQUID amplifier and high-Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark noise equivalent power of 3.2 \\times 10 -19 W/\\sqrt{Hz} developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.
We describe the development of a frequency-domain multiplexer (MUX) to read out arrays of superconducting transition-edge sensors (TES). Fabrication of large-format arrays of these sensors is becoming practical; however, reading out each sensor in the array is a major instrumental challenge that is possibly solved by frequency-domain multiplexing. Each sensor is AC biased at a different frequency, ranging from 380 kHz to 1 MHz. The sensor signal amplitude-modulates its respective AC bias frequency. An LC filter associated with each sensor suppresses Johnson noise from the other sensors. The signals are combined at a current summing node and measured by a single superconducting quantum interference device (SQUID). The individual signals from each sensor are then lock-in detected by room temperature electronics. Test chips with fully lithographed LC filters for up to 32 channels have been designed and fabricated. The capacitance and inductance values have been measured and are close to the design goals. We discuss the basic principles of frequency-domain multiplexing, the design and testing of the test chips, and the implementation of a practical system.
We describe our frequency-domain readout multiplexer for transition-edge sensor (TES) bolometers and present measurements of an eight-channel multiplexer. Each sensor is biased with a sinusoidal bias at a distinct frequency. As the sensor absorbs power, it amplitude-modulates its sinusoidal bias. Sensor currents are summed and measured with a single superconducting quantum interference device (SQUID) array. The SQUID array consists of 100 dc-SQUID's in series and is operated with shunt feedback electronics which have a slew rate of 1.210/sup 7/ /spl Phi//sub 0//s. A tuned filter consisting of an inductor and capacitor are placed in series with each sensor to both limit the bandwidth of the Nyquist noise from each sensor and to allow us to bias all multiplexed sensors with a common wire. We place an upper limit on crosstalk between adjacent channels of 0.004, well below our design requirements. Demodulated noise spectra from multiplexed sensors show the expected white noise levels at frequencies above 200 mHz.