arXiv:1601.06938 · Applied Physics B

Multichannel optical atomic magnetometer operating in unshielded environment

G. Bevilacqua, V. Biancalana, P. Chessa, Yordanka V. Dancheva

Published Apr 1, 2016• 58 citations
arXivHTMLPDF
DOI
10.1007/s00340-016-6375-2

Related papers

Ultra-high consistency multichannel SERF atomic magnetometer based on diffractive optics

Jiajie Li, Ying Liu, Zhen Chai +3 more

Sensors and Actuators A Physical•Nov 24, 2023•15 citations

A subfemtotesla multichannel atomic magnetometer

Iannis K. Kominis, Thomas W. Kornack, Joel C. Allred +1 more

Nature•Apr 1, 2003•1,628 citations

All-optical atomic magnetometry

Dmitry Budker

Bulletin of the American Physical Society•May 19, 2006•0 citations

High-Sensitivity Operation of Unshielded Radio Frequency Atomic Magnetometers Using Phase-Lock Techniques

Han Yao, Ferruccio Renzoni

High sensitivity operation of radio-frequency atomic magnetometers in unshielded environment requires compensation of low-frequency fluctuations of the ambient magnetic field. Here we demonstrate the use of phase-lock techniques to stabilise the magnetic environment and achieve high sensitivity at high frequencies. This is achieved by using the output of the atomic magnetometer both for stabilisation and for measurement purposes. The approach is validated by a proof-of-concept in unshielded environment. The phase-lock approach is also compared to the standard approach where the magnetic environment is stabilised with the help of a set of fluxgate magnetometers, and it is shown that the phase-lock approach features superior performances in signal detection.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•3 citations

An all-optical vector atomic magnetometer for fundamental physics applications

D. Wurm, Ignacio Mateos, E. Zhivun +4 more

Bulletin of the American Physical Society•Jun 3, 2014•0 citations

High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer

Han Yao, Benjamin Maddox, Ferruccio Renzoni

Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.

Optics Express•Oct 21, 2022•29 citations
High sensitivity operation of radio-frequency atomic magnetometers in unshielded environment requires compensation of low-frequency fluctuations of the ambient magnetic field. Here we demonstrate the use of phase-lock techniques to stabilise the magnetic environment and achieve high sensitivity at high frequencies. This is achieved by using the output of the atomic magnetometer both for stabilisation and for measurement purposes. The approach is validated by a proof-of-concept in unshielded environment. The phase-lock approach is also compared to the standard approach where the magnetic environment is stabilised with the help of a set of fluxgate magnetometers, and it is shown that the phase-lock approach features superior performances in signal detection.
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.