Cryogenic resonator design for trapped ion experiments in Paul traps

Matthias F. Brandl, Philipp Schindler, Thomas Monz, R. Blatt

Published May 18, 2016• 12 citations
arXivHTMLPDF

Abstract

Trapping ions in Paul traps require high radio frequency voltages, which are generated using resonators. When operating traps in a cryogenic environment, an in-vacuum resonator showing low loss is crucial to limit the thermal load to the cryostat. In this study, we present a guide for the design and production of compact, shielded cryogenic resonators. We produced and characterized three different types of resonators and furthermore demonstrate efficient impedance matching of these resonators at cryogenic temperatures.

DOI
10.1007/s00340-016-6430-z

Related papers

Compact radio-frequency resonator for cryogenic ion traps

Davide Gandolfi, M. Niedermayr, M. Kumph +2 more

We report on the investigation and implementation of a lumped-component, radio-frequency resonator used in a cryogenic vacuum environment to drive an ion trap. The resonator was required to achieve the voltages necessary to trap (~100 V), while dissipating very little power. Ultimately, for an input voltage of 1.35 V, a voltage gain of 100 was measured at 5.7 K, using a design which dissipated only 18 mW. The resonator operated at a frequency of 7.64 MHz and had a Q of 700. Single (40)Ca(+) ions were confined in a trap driven by this device, providing proof of successful resonator operation at low temperature.

arXiv:1204.5004•Review of Scientific Instruments•Aug 1, 2012•20 citations

Active impedance matching of a cryogenic radio frequency resonator for ion traps

M. Schubert, L. Kilzer, T. Dubielzig +3 more

A combination of direct current (DC) fields and high amplitude radio frequency (RF) fields is necessary to trap ions in a Paul trap. Such high electric RF fields are usually reached with the help of a resonator in close proximity to the ion trap. Ion trap based quantum computers profit from good vacuum conditions and low heating rates that cryogenic environments provide. However, an impedance matching network between the resonator and its RF source is necessary, as an unmatched resonator would require higher input power due to power reflection. The reflected power would not contribute to the RF trapping potential, and the losses in the cable induce additional heat into the system. The electrical properties of the matching network components change during cooling, and a cryogenic setup usually prohibits physical access to integrated components while the experiment is running. This circumstance leads to either several cooling cycles to improve the matching at cryogenic temperatures or the operation of poorly matched resonators. In this work, we demonstrate an RF resonator that is actively matched to the wave impedance of coaxial cables and the signal source. The active part of the matching circuit consists of a varactor diode array. Its capacitance depends on the DC voltage applied from outside the cryostat. We present measurements of the power reflection, the Q-factor, and higher harmonic signals resulting from the nonlinearity of the varactor diodes. The RF resonator is tested in a cryostat at room temperature and cryogenic temperatures, down to 4.3 K. A superior impedance matching for different ion traps can be achieved with this type of resonator.

Review of Scientific Instruments•Sep 1, 2022•3 citations

Design and characterization of a cryogenic vacuum chamber for ion trapping experiments

Darian M. Hartsell, J. M. Gray, Chris Shappert +5 more

We present the design and characterization of a cryogenic vacuum chamber incorporating mechanical isolation from vibrations, a high numerical-aperture in-vacuum imaging objective, in-vacuum magnetic shielding, and an antenna for global radio frequency manipulation of trapped ions. The cold shield near 4 K is mechanically referenced to an underlying optical table via thermally insulating supports and exhibits root mean square vibrations less than 7.61(4) nm. Using the in-vacuum objective, we can detect 397 nm photons from a trapped 40Ca+ ion with 1.77% efficiency and achieve 99.9963(4)% single-shot state-detection fidelity in 50 μs. To characterize the efficacy of the magnetic shields, we perform Ramsey experiments on the ground-state qubit and obtain a coherence time of 24(2) ms, which extends to 0.25(1) s with a single spin-echo pulse. XY4 and XY32 dynamical decoupling sequences driven via the radio frequency antenna extend the coherence to 0.72(2) and 0.81(3) s, respectively.

arXiv:2510.01557•Applied Physics Letters•Jan 19, 2026•1 citation

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

Tobias Leopold, S. A. King, P. Micke +5 more

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

•Jan 1, 2019•41 citations

Superconducting NbTi Radiofrequency Resonator for Surface ion Traps

M. Schubert, D. Fegelein, Dominik Hanisch +3 more

Trapped-ion qubits are one approach among many for achieving scalable quantum computers. An ion trap has to be operated with several dc and radio frequency (rf) signals to trap and control its qubits. Many ion trap setups are operated at cryogenic temperatures to reduce thermal influences, to reach very high vacuum, and to achieve high fidelity for quantum operations. A resonance circuit, consisting of a coil and the capacitance of the trap electrodes, is used to step-up a low power rf signal to high amplitudes in close proximity to the ion trap. These ac fields are used to confine ions$70 \,{\rm \mu }\mathrm{m}$above a surface ion trap chip. An increased quality factor (Q-factor) of the resonance circuit leads to a higher voltage gain, but the experiment also benefits from a better attenuation of parasitic frequency components in the confining electric field. The Q-factor is inversely proportional to the trap capacitance. Since ion traps are growing in size due to a larger number of qubits, the capacitance is increasing. Therefore, the development of a coil with low losses becomes even more important. In this work, we present the setup of a superconducting coil for a high-Q resonator, measurements of the Q-factor, and its temperature dependency. The coil is made of a niobium-titanium (NbTi) wire wound on a threaded bobbin made of ceramics and equipped with further thermalization structures. The superconducting resonator is a very promising approach to satisfy the needs for future trapped-ion quantum computing setups.

IEEE Transactions on Applied Superconductivity•Jan 8, 2024•0 citations

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

T. Leopold, S. A. King, P. Micke +5 more

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

arXiv:1901.03082•Review of Scientific Instruments•Jul 1, 2019•50 citations
Trapping ions in Paul traps require high radio frequency voltages, which are generated using resonators. When operating traps in a cryogenic environment, an in-vacuum resonator showing low loss is crucial to limit the thermal load to the cryostat. In this study, we present a guide for the design and production of compact, shielded cryogenic resonators. We produced and characterized three different types of resonators and furthermore demonstrate efficient impedance matching of these resonators at cryogenic temperatures.
We report on the investigation and implementation of a lumped-component, radio-frequency resonator used in a cryogenic vacuum environment to drive an ion trap. The resonator was required to achieve the voltages necessary to trap (~100 V), while dissipating very little power. Ultimately, for an input voltage of 1.35 V, a voltage gain of 100 was measured at 5.7 K, using a design which dissipated only 18 mW. The resonator operated at a frequency of 7.64 MHz and had a Q of 700. Single (40)Ca(+) ions were confined in a trap driven by this device, providing proof of successful resonator operation at low temperature.
A combination of direct current (DC) fields and high amplitude radio frequency (RF) fields is necessary to trap ions in a Paul trap. Such high electric RF fields are usually reached with the help of a resonator in close proximity to the ion trap. Ion trap based quantum computers profit from good vacuum conditions and low heating rates that cryogenic environments provide. However, an impedance matching network between the resonator and its RF source is necessary, as an unmatched resonator would require higher input power due to power reflection. The reflected power would not contribute to the RF trapping potential, and the losses in the cable induce additional heat into the system. The electrical properties of the matching network components change during cooling, and a cryogenic setup usually prohibits physical access to integrated components while the experiment is running. This circumstance leads to either several cooling cycles to improve the matching at cryogenic temperatures or the operation of poorly matched resonators. In this work, we demonstrate an RF resonator that is actively matched to the wave impedance of coaxial cables and the signal source. The active part of the matching circuit consists of a varactor diode array. Its capacitance depends on the DC voltage applied from outside the cryostat. We present measurements of the power reflection, the Q-factor, and higher harmonic signals resulting from the nonlinearity of the varactor diodes. The RF resonator is tested in a cryostat at room temperature and cryogenic temperatures, down to 4.3 K. A superior impedance matching for different ion traps can be achieved with this type of resonator.
We present the design and characterization of a cryogenic vacuum chamber incorporating mechanical isolation from vibrations, a high numerical-aperture in-vacuum imaging objective, in-vacuum magnetic shielding, and an antenna for global radio frequency manipulation of trapped ions. The cold shield near 4 K is mechanically referenced to an underlying optical table via thermally insulating supports and exhibits root mean square vibrations less than 7.61(4) nm. Using the in-vacuum objective, we can detect 397 nm photons from a trapped 40Ca+ ion with 1.77% efficiency and achieve 99.9963(4)% single-shot state-detection fidelity in 50 μs. To characterize the efficacy of the magnetic shields, we perform Ramsey experiments on the ground-state qubit and obtain a coherence time of 24(2) ms, which extends to 0.25(1) s with a single spin-echo pulse. XY4 and XY32 dynamical decoupling sequences driven via the radio frequency antenna extend the coherence to 0.72(2) and 0.81(3) s, respectively.
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
Trapped-ion qubits are one approach among many for achieving scalable quantum computers. An ion trap has to be operated with several dc and radio frequency (rf) signals to trap and control its qubits. Many ion trap setups are operated at cryogenic temperatures to reduce thermal influences, to reach very high vacuum, and to achieve high fidelity for quantum operations. A resonance circuit, consisting of a coil and the capacitance of the trap electrodes, is used to step-up a low power rf signal to high amplitudes in close proximity to the ion trap. These ac fields are used to confine ions70 μm70 \,{\rm \mu }\mathrm{m}70μmabove a surface ion trap chip. An increased quality factor (Q-factor) of the resonance circuit leads to a higher voltage gain, but the experiment also benefits from a better attenuation of parasitic frequency components in the confining electric field. The Q-factor is inversely proportional to the trap capacitance. Since ion traps are growing in size due to a larger number of qubits, the capacitance is increasing. Therefore, the development of a coil with low losses becomes even more important. In this work, we present the setup of a superconducting coil for a high-Q resonator, measurements of the Q-factor, and its temperature dependency. The coil is made of a niobium-titanium (NbTi) wire wound on a threaded bobbin made of ceramics and equipped with further thermalization structures. The superconducting resonator is a very promising approach to satisfy the needs for future trapped-ion quantum computing setups.
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.