Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1501.01943 · Physical Review A

Stability enhancement by joint phase measurements in a single cold atomic fountain

M. Meunier, Indranil Dutta, Rémi Geiger, Christine Guerlin, Carlos L. Garrido Alzar, Arnaud Landragin

Published Dec 22, 2014• 40 citations
arXivHTMLPDF

Abstract

We propose a method of joint interrogation in a single atom interferometer which overcomes the dead time between consecutive measurements in standard cold atomic fountains. The joint operation enables for a faster averaging of the Dick effect associated with the local oscillator noise in clocks and with vibration noise in cold atom inertial sensors. Such an operation allows one to achieve the lowest stability limit due to atom shot noise. We demonstrate a multiple joint operation in which up to five clouds of atoms are interrogated simultaneously in a single setup. The essential feature of multiple joint operation, demonstrated here for a microwave Ramsey interrogation, can be generalized to go beyond the current stability limit associated with dead times in present-day cold atom interferometer inertial sensors.

DOI
10.1103/physreva.90.063633

Related papers

Cold-atom inertial sensor without deadtime

Bess Fang, Indranil Dutta, Denis Savoie +4 more

We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times. Noise aliasing and dead times are consequences of the sequential operation which is intrinsic to cold-atom atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√(Hz) in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.

arXiv:1605.03869•European Frequency and Time Forum•Apr 1, 2016•5 citations

Cold-atom inertial sensor without deadtime

Bess Fang, Denis Savoie, N. Mielec +5 more

We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√Hz in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Continuous Cold-Atom Inertial Sensor with 1 nrad/sec Rotation Stability

Indranil Dutta, Denis Savoie, Bess Fang +4 more

We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.

arXiv:1604.00940•Physical Review Letters•May 6, 2016•285 citations

Interleaved Atom Interferometry for High Sensitivity Inertial Measurements

Denis Savoie, Matteo Altorio, Bess Fang +3 more

We report on interleaved operation of a cold-atom inertial sensor, where three atomic clouds are simultaneously probed in an atom interferometer featuring 4 Hz sampling rate and interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise and allows us to perform dynamic rotation measurements in a so far unexplored range. We demonstrate sensitivity of 30 nrad.s-1·Hz-1/2and reach the long-term stability of 3·10-10rads-1, which competes with the best stability levels obtained with fiber-optic gyroscopes. Our work validated interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity gradiometry, searches for dark matter, or gravitational wave detection.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•12 citations

Interleaved atom interferometry for high sensitivity inertial measurements

Matteo Altorio, Romain Gautier, Denis Savoie +3 more

Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interferometer featuring a 3.75 Hz sampling rate and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise, and allows us to perform dynamic rotation measurements in a so-far unexplored range. We demonstrate a stability of $3\times 10^{-10}$ rad.s$^{-1}$, which competes with the best stability levels obtained with fiber-optics gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity-gradiometry, searches for dark matter, or gravitational wave detection.

•Apr 8, 2019•72 citations

Improved absolute clock stability by the joint interrogation of two atomic ensembles

Weidong Li, Shuyuan Wu, Augusto Smerzi +1 more

Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly fluctuating local oscillator (LO) frequency, which introduces ``phase slips'' for long interrogation times and hence the failure of the frequency-feedback loop. Here we propose a strategy to improve the stability of atomic clocks by interrogating two atomic ensembles sharing the same LO. The two ensembles are prepared in coherent spin states pointing along orthogonal directions in the Bloch sphere. While standard Ramsey interrogation can only determine phases unambiguously in the interval $[\ensuremath{-}\ensuremath{\pi}/2,\ensuremath{\pi}/2]$, the joint interrogation allows for an extension to $[\ensuremath{-}\ensuremath{\pi},\ensuremath{\pi}]$, resulting in a relaxed restriction of the Ramsey time and improvement of absolute clock stability. Theoretical predictions are supported by ab initio numerical simulation for white and correlated LO noise. While our basic protocol uses uncorrelated atoms, we further extended it to include spin-squeezing and further improving the scaling of clock stability with the number of atoms. Our protocol can be readily tested in current state-of-the-art experiments.

arXiv:2104.14309•Physical Review A•May 19, 2022•8 citations
We propose a method of joint interrogation in a single atom interferometer which overcomes the dead time between consecutive measurements in standard cold atomic fountains. The joint operation enables for a faster averaging of the Dick effect associated with the local oscillator noise in clocks and with vibration noise in cold atom inertial sensors. Such an operation allows one to achieve the lowest stability limit due to atom shot noise. We demonstrate a multiple joint operation in which up to five clouds of atoms are interrogated simultaneously in a single setup. The essential feature of multiple joint operation, demonstrated here for a microwave Ramsey interrogation, can be generalized to go beyond the current stability limit associated with dead times in present-day cold atom interferometer inertial sensors.
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times. Noise aliasing and dead times are consequences of the sequential operation which is intrinsic to cold-atom atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√(Hz) in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√Hz in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.
We report on interleaved operation of a cold-atom inertial sensor, where three atomic clouds are simultaneously probed in an atom interferometer featuring 4 Hz sampling rate and interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise and allows us to perform dynamic rotation measurements in a so far unexplored range. We demonstrate sensitivity of 30 nrad.s-1·Hz-1/2and reach the long-term stability of 3·10-10rads-1, which competes with the best stability levels obtained with fiber-optic gyroscopes. Our work validated interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity gradiometry, searches for dark matter, or gravitational wave detection.
Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interferometer featuring a 3.75 Hz sampling rate and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise, and allows us to perform dynamic rotation measurements in a so-far unexplored range. We demonstrate a stability of 3×10−103\times 10^{-10}3×10−10 rad.s−1^{-1}−1, which competes with the best stability levels obtained with fiber-optics gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity-gradiometry, searches for dark matter, or gravitational wave detection.
Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly fluctuating local oscillator (LO) frequency, which introduces ``phase slips'' for long interrogation times and hence the failure of the frequency-feedback loop. Here we propose a strategy to improve the stability of atomic clocks by interrogating two atomic ensembles sharing the same LO. The two ensembles are prepared in coherent spin states pointing along orthogonal directions in the Bloch sphere. While standard Ramsey interrogation can only determine phases unambiguously in the interval $[\ensuremath{-}\ensuremath{\pi}/2,\ensuremath{\pi}/2]$, the joint interrogation allows for an extension to $[\ensuremath{-}\ensuremath{\pi},\ensuremath{\pi}]$, resulting in a relaxed restriction of the Ramsey time and improvement of absolute clock stability. Theoretical predictions are supported by ab initio numerical simulation for white and correlated LO noise. While our basic protocol uses uncorrelated atoms, we further extended it to include spin-squeezing and further improving the scaling of clock stability with the number of atoms. Our protocol can be readily tested in current state-of-the-art experiments.