Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1501.00570 · Physical Review B

Qubit detection with a T-shaped double quantum dot detector

JunYan Luo, HuJun Jiao, Jing Hu, Xiao-Ling He, Xiaoli Lang, Shi-Kuan Wang

Published Jul 7, 2015• 5 citations
arXivHTMLPDF

Abstract

We propose to continuously monitor a charge qubit by utilizing a T-shaped double quantum dot detector, in which the qubit and double dot are arranged in such a unique way that the detector turns out to be particularly susceptible to the charge states of the qubit. Special attention is paid to the regime where acquisition of qubit information and backaction upon the measured system exhibit nontrivial correlation. The intrinsic dynamics of the qubit gives rise to dynamical blockade of tunneling events through the detector, resulting in a super-Poissonian noise. However, such a pronounced enhancement of the detector's shot noise does not necessarily produce a rising dephasing rate. In contrast, an inhibition of dephasing is entailed by the reduction of information acquisition in the dynamically blockaded regimes. We further reveal the important impact of the charge fluctuations on the measurement characteristics. Noticeably, under the condition of symmetric junction capacitances the noise pedestal of the circuit current is completely suppressed, leading to a divergent signal-to-noise ratio, and eventually to a violation of the Korotkov-Averin bound in quantum measurement. Our study offers the possibility for a double dot detector to reach the quantum limited effectiveness in a transparent manner.

DOI
10.1103/physrevb.92.045107

Related papers

Continuous Quantum Measurement with Independent Detector Cross Correlations

Andrew N. Jordan, Μ. Büttiker

We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.

arXiv:cond-mat/0505044•Physical Review Letters•Nov 21, 2005•66 citations

Qubit Measurements with a Double-Dot Detector

T. Gilad, S. A. Gurvitz

We propose to monitor a qubit with a double-dot (DD) resonant-tunneling detector, which can operate at higher temperatures than a single-dot detector. In order to assess the effectiveness of this device, we derive rate equations for the density matrix of the entire system. We show that the signal-to-noise ratio can be greatly improved by a proper choice of the parameters and location of the detector. We demonstrate that quantum interference effects within the DD detector play an important role in the measurement. Surprisingly, these effects produce a systematic measurement error, even when the entire system is in a stationary state.

arXiv:cond-mat/0606376•Physical Review Letters•Sep 14, 2006•42 citations

Quantum measurement characteristics of a double-dot single electron transistor

HuJun Jiao, Xin-Qi Li, JunYan Luo

Owing to a few unique advantages, the double-dot single electron transistor has been proposed as an alternative detector for charge states. In this work, we present a further study for its signal-to-noise property, based on a full analysis of the setup configuration symmetry. It is found that the effectiveness of the double-dot detector can approach that of an ideal detector, if the symmetric capacitive coupling is taken into account. The quantum measurement efficiency is also analyzed by comparing the measurement time with the measurement-induced dephasing time.

arXiv:cond-mat/0612692•Physical Review B•Apr 26, 2007•19 citations

Non-Markovian dynamics and noise characteristics in continuous measurement of a solid-state charge qubit

JunYan Luo, HuJun Jiao, BiTao Xiong +2 more

We investigate the non-Markovian characteristics in continuous measurement of a charge qubit by a quantum point contact. The backflow of information from the reservoir to the system in the non-Markovian domain gives rise to strikingly different qubit relaxation and dephasing in comparison with the Markovian case. The intriguing non-Markovian dynamics is found to have a direct impact on the output noise feature of the detector. Unambiguously, we observe that the non-Markovian memory effect results in an enhancement of the signal-to-noise ratio, which can even exceed the upper limit of “4,” leading thus to the violation of the Korotkov-Averin bound in quantum measurement. Our study thus may open new possibilities to improve detector's measurement efficiency in a direct and transparent way.

arXiv:1203.2233•Journal of Applied Physics•Nov 4, 2013•8 citations

Coherence of an Electronic Two-Level System under Continuous Charge Sensing by a Quantum Dot Detector

Subhomoy Haldar, Morten I. K. Munk, Harald Havir +7 more

We investigate experimentally the quantum coherence of an electronic two-level system in a double quantum dot under continuous charge detection. The charge state of the two-level system is monitored by a capacitively coupled single quantum dot detector that imposes a backaction effect on the system. The measured backaction is well described by an additional decoherence rate, approximately linearly proportional to the detector electron tunneling rate. We provide a model for the decoherence rate arising due to level detuning fluctuations induced by detector charge fluctuations. The theory predicts a factor of 2 lower decoherence rates than observed in the experiment, suggesting the need for a more elaborate theory accounting for additional sources of decoherence.

arXiv:2406.11383•Physical Review Letters•Jan 15, 2025•5 citations

Dynamics of a mesoscopic charge quantum bit under continuous quantum measurement

Hsi‐Sheng Goan, Gerard J Milburn

We present the conditional quantum dynamics of an electron tunneling between two quantum dots subject to a measurement using a low transparency point contact or tunnel junction. The double dot system forms a single qubit and the measurement corresponds to a continuous in time readout of the occupancy of the quantum dot. We illustrate the difference between conditional and unconditional dynamics of the qubit. The conditional dynamics is discussed in two regimes depending on the rate of tunneling through the point contact: quantum jumps, in which individual electron tunneling current events can be distinguished, and a diffusive dynamics in which individual events are ignored, and the time-averaged current is considered as a continuous diffusive variable. We include the effect of inefficient measurement and the influence of the relative phase between the two tunneling amplitudes of the double dot/point contact system.

arXiv:cond-mat/0103005•Physical review. B, Condensed matter•Nov 16, 2001•121 citations
We propose to continuously monitor a charge qubit by utilizing a T-shaped double quantum dot detector, in which the qubit and double dot are arranged in such a unique way that the detector turns out to be particularly susceptible to the charge states of the qubit. Special attention is paid to the regime where acquisition of qubit information and backaction upon the measured system exhibit nontrivial correlation. The intrinsic dynamics of the qubit gives rise to dynamical blockade of tunneling events through the detector, resulting in a super-Poissonian noise. However, such a pronounced enhancement of the detector's shot noise does not necessarily produce a rising dephasing rate. In contrast, an inhibition of dephasing is entailed by the reduction of information acquisition in the dynamically blockaded regimes. We further reveal the important impact of the charge fluctuations on the measurement characteristics. Noticeably, under the condition of symmetric junction capacitances the noise pedestal of the circuit current is completely suppressed, leading to a divergent signal-to-noise ratio, and eventually to a violation of the Korotkov-Averin bound in quantum measurement. Our study offers the possibility for a double dot detector to reach the quantum limited effectiveness in a transparent manner.
We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.
We propose to monitor a qubit with a double-dot (DD) resonant-tunneling detector, which can operate at higher temperatures than a single-dot detector. In order to assess the effectiveness of this device, we derive rate equations for the density matrix of the entire system. We show that the signal-to-noise ratio can be greatly improved by a proper choice of the parameters and location of the detector. We demonstrate that quantum interference effects within the DD detector play an important role in the measurement. Surprisingly, these effects produce a systematic measurement error, even when the entire system is in a stationary state.
Owing to a few unique advantages, the double-dot single electron transistor has been proposed as an alternative detector for charge states. In this work, we present a further study for its signal-to-noise property, based on a full analysis of the setup configuration symmetry. It is found that the effectiveness of the double-dot detector can approach that of an ideal detector, if the symmetric capacitive coupling is taken into account. The quantum measurement efficiency is also analyzed by comparing the measurement time with the measurement-induced dephasing time.
We investigate the non-Markovian characteristics in continuous measurement of a charge qubit by a quantum point contact. The backflow of information from the reservoir to the system in the non-Markovian domain gives rise to strikingly different qubit relaxation and dephasing in comparison with the Markovian case. The intriguing non-Markovian dynamics is found to have a direct impact on the output noise feature of the detector. Unambiguously, we observe that the non-Markovian memory effect results in an enhancement of the signal-to-noise ratio, which can even exceed the upper limit of “4,” leading thus to the violation of the Korotkov-Averin bound in quantum measurement. Our study thus may open new possibilities to improve detector's measurement efficiency in a direct and transparent way.
We investigate experimentally the quantum coherence of an electronic two-level system in a double quantum dot under continuous charge detection. The charge state of the two-level system is monitored by a capacitively coupled single quantum dot detector that imposes a backaction effect on the system. The measured backaction is well described by an additional decoherence rate, approximately linearly proportional to the detector electron tunneling rate. We provide a model for the decoherence rate arising due to level detuning fluctuations induced by detector charge fluctuations. The theory predicts a factor of 2 lower decoherence rates than observed in the experiment, suggesting the need for a more elaborate theory accounting for additional sources of decoherence.
We present the conditional quantum dynamics of an electron tunneling between two quantum dots subject to a measurement using a low transparency point contact or tunnel junction. The double dot system forms a single qubit and the measurement corresponds to a continuous in time readout of the occupancy of the quantum dot. We illustrate the difference between conditional and unconditional dynamics of the qubit. The conditional dynamics is discussed in two regimes depending on the rate of tunneling through the point contact: quantum jumps, in which individual electron tunneling current events can be distinguished, and a diffusive dynamics in which individual events are ignored, and the time-averaged current is considered as a continuous diffusive variable. We include the effect of inefficient measurement and the influence of the relative phase between the two tunneling amplitudes of the double dot/point contact system.