Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1412.2713 · Experimental Astronomy

Design of a dual species atom interferometer for space

Thilo Schuldt, Christian Schubert, Markus Krutzik, Lluis Gesa Bote, Naceur Gaaloul, Jonas Hartwig, Holger Ahlers, Waldemar Herr, Katerine Posso-Trujillo, Jan Rudolph, Stephan Seidel, Thijs Wendrich, Wolfgang Ertmer, Sven Herrmann, André Kubelka-Lange, Alexander Milke, Benny Rievers, Emanuele Rocco, Andrew Hinton, Kai Bongs, Markus Oswald, Matthias Franz, Matthias Hauth, Achim Peters, Ahmad Bawamia, Andreas Wicht, Baptiste Battelier, Andréa D Bertoldi, Philippe Bouyer, Arnaud Landragin, Didier Massonnet, Thomas Lévèque, André Wenzlawski, Ortwin Hellmig, Patrick Windpassinger, Klaus Sengstock, Wolf von Klitzing, Chris Chaloner, David Summers, Philip Ireland, Ignacio Mateos, Carlos F. Sopuerta, Fiodor Sorrentino, Guglielmo M. Tino, Michael Williams, Christian Trenkel, Domenico Gerardi, Michael Chwalla, Johannes Burkhardt, Ulrich Johann, Astrid Heske, Eric Wille, Martin Gehler, L. Cacciapuoti, Norman Gürlebeck, Claus Braxmaier, Ernst Maria Rasel

Published Mar 7, 2015• 66 citations
arXivHTMLPDF
DOI
10.1007/s10686-014-9433-y

Related papers

Quantum gas mixtures and dual-species atom interferometry in space

Ethan Elliott, David C. Aveline, N. P. Bigelow +24 more

Nature•Nov 15, 2023•47 citations

All acousto-optic modulator laser system for a 12 m fountain-type dual-species atom interferometer

Chuan He, Sitong Yan, Lin Zhou +8 more

We design and implement a laser system for 85 R b and 87 R b dual-species atom interferometers based on acousto-optic frequency shift and tapered amplifier laser technologies. We use eight-pass acousto-optic modulators to generate repumping lasers for 85 R b and 87 R b atoms. The maximum frequency shift of the laser is 2.8 GHz, and the diffraction efficiency is higher than 20%. We use high-frequency acousto-optic modulators to generate the Raman lasers. This laser system uses only two seed lasers to provide the various frequencies required by 85 R b and 87 R b dual-species atom interferometers, which greatly improves laser usage. The laser system is applied in the equivalence principle test experiment using an 85 R b and 87 R b dual-species atom interferometer. The signal of atoms launched to 12 meters is successfully observed, and the resolution of gravity differential measurement is improved from 8 × 10 − 9 g to 1 × 10 − 10 g .

Applied Optics•May 26, 2021•5 citations

Perspectives for atom interferometers in space

Christian Schubert, Ernst Maria Rasel, Wolfgang A. Ertmer +2 more

cosp•Jul 1, 2018•0 citations

Analysis and suppression of wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers

Jiangong Hu, Xi Chen, Jie Fang +4 more

The wave-front aberration of Raman beams induces phase noise in atom interferometers and thus limits the performance of atom interferometers. We theoretically analyze the wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers, and propose an expansion-rate-selection method to suppress the wave-front-aberration phase noise in both isotopic and nonisotopic atom interferometers. The suppression ratio is about 10 at the expense of half the number of atoms. The simulation based on appropriate experimental parameters shows that the wave-front aberration caused standard deviations to the E\"otv\"os coefficient in weak-equivalence-principle tests using $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ and $^{41}\mathrm{K}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ are $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ and $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$. Better results can be obtained by improving the wave-front quality and utilizing atom cloud with lower temperature. The analysis and suppression of wave-front-aberration phase noise will be useful for the design of high-precision atom interferometer--based weak-equivalence-principle tests both on ground and in space.

Physical Review A•Aug 21, 2017•19 citations

Atom interferometer sensor development and applications in space

Nan Yu

cosp•Jan 1, 2010•0 citations

Simultaneous Dual-Species Atom Interferometry

Alexis Bonnin, Nassim Zahzam, Yannick Bidel +1 more

Bulletin of the American Physical Society•Jun 9, 2015•0 citations
We design and implement a laser system for 85 R b and 87 R b dual-species atom interferometers based on acousto-optic frequency shift and tapered amplifier laser technologies. We use eight-pass acousto-optic modulators to generate repumping lasers for 85 R b and 87 R b atoms. The maximum frequency shift of the laser is 2.8 GHz, and the diffraction efficiency is higher than 20%. We use high-frequency acousto-optic modulators to generate the Raman lasers. This laser system uses only two seed lasers to provide the various frequencies required by 85 R b and 87 R b dual-species atom interferometers, which greatly improves laser usage. The laser system is applied in the equivalence principle test experiment using an 85 R b and 87 R b dual-species atom interferometer. The signal of atoms launched to 12 meters is successfully observed, and the resolution of gravity differential measurement is improved from 8 × 10 − 9 g to 1 × 10 − 10 g .
The wave-front aberration of Raman beams induces phase noise in atom interferometers and thus limits the performance of atom interferometers. We theoretically analyze the wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers, and propose an expansion-rate-selection method to suppress the wave-front-aberration phase noise in both isotopic and nonisotopic atom interferometers. The suppression ratio is about 10 at the expense of half the number of atoms. The simulation based on appropriate experimental parameters shows that the wave-front aberration caused standard deviations to the E\"otv\"os coefficient in weak-equivalence-principle tests using $^{85}\mathrm{Rb}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ and $^{41}\mathrm{K}\text{\ensuremath{-}}^{87}\mathrm{Rb}$ are $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ and $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$. Better results can be obtained by improving the wave-front quality and utilizing atom cloud with lower temperature. The analysis and suppression of wave-front-aberration phase noise will be useful for the design of high-precision atom interferometer--based weak-equivalence-principle tests both on ground and in space.