Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1409.4094 · New Journal of Physics

Crossover between strong and weak measurement in interacting many-body systems

Iliya Esin, Alessandro Romito, Yaroslav M. Blanter, Yuval Gefen

Published Jan 8, 2016• 3 citations
arXivHTMLPDF

Abstract

Measurements with variable system–detector interaction strength, ranging from weak to strong, have been recently reported in a number of electronic nanosystems. In several such instances many-body effects play a significant role. Here we consider the weak-to-strong crossover for a setup consisting of an electronic Mach–Zehnder interferometer, where a second interferometer is employed as a detector. In the context of a conditional which-path protocol, we define a generalized conditional value (GCV), and determine its full crossover between the regimes of weak and strong (projective) measurement. We find that the GCV has an oscillatory dependence on the system–detector interaction strength. These oscillations are a genuine many-body effect, and can be experimentally observed through the voltage dependence of cross current correlations.

DOI
10.1088/1367-2630/18/1/013016

Related papers

Tomography of Many-Body Weak Values: Mach-Zehnder Interferometry

Vadim Shpitalnik, Yuval Gefen, Alessandro Romito

We propose and study a weak value (WV) protocol in the context of a solid state setup, specifically, an electronic Mach-Zehnder interferometer. This is the first specific proposal to measure both the real and imaginary part (i.e., complete tomography) of a WV. We also analyze the manifestation of many-body physics in the WV to be measured, including finite temperature and shot-noise-like contributions.

arXiv:0805.2737•Physical Review Letters•Nov 24, 2008•38 citations

Anomalous weak values in a generalized Mach-Zehnder interferometer extracted directly from intensity measurements

Ismaele V. Masiello, Hartmut Lemmel, Andreas Dvorak +2 more

Weak values provide a powerful framework for characterizing quantum systems. Their experimental extraction conventionally relies on weak conditioned von Neumann measurements, involving weak interactions and meter states that increase experimental complexity and often limit measurement efficiency. Here we introduce a method to fully characterize path weak-values in a generalized Mach-Zehnder interferometer employing neither meter states nor weak interactions. We experimentally demonstrate the technique in matter-wave interferometry. We identify anomalous weak values and, equivalently, negative quasiprobability distributions, which reflect the nonclassical behavior of the quantum system. The approach relies uniquely on intensity measurements at the output ports of the interferometer combined with controlled relative phase shifts between the paths. The absence of meter states enables considerable simplification of the setup and shorter measurement times, while preserving full access to weak values with comparable or increased accuracy. The scheme is directly applicable to a broad class of experiments involving two-level quantum systems.

quant-pharXiv:2606.24798•npj Quantum Information•Jun 24, 2026•0 citations

How to extract weak values from a mesoscopic electronic system

Iliya Esin, Alessandro Romito, Yuval Gefen

Weak value (WV) protocols may lead to extreme expectation values that are larger than the corresponding orthodox expectation values. Recent works have proposed to implement this concept in nano-scale electronic systems. Here we address the issue of how one calibrates the setup in question, maximizes the measurement's sensitivity, and extracts distinctly large WVs. Our concrete setup consists of two Mach-Zehnder interferometers (MZIs): the "system" and the "detector". Such setups have already been implemented in experiment.

•Sep 1, 2016•2 citations

Simultaneous path weak-measurements in neutron interferometry

Armin Danner, Ismaele Vincent Masiello, Andreas Dvorak +4 more

The statistical properties of the detection events constituting the interference fringes at the output of an interferometer are well-known. Nevertheless, there is still no unified view of what is happening to a quantum system inside an interferometer. Strong measurements of path operators destroy the interference effect. In weak measurements, an observable is weakly coupled to a pointer system and the resulting weak values quantify the observable by minimally disturbing the system. Previous which-way experiments with weak measurements could extract either the real or imaginary part of a single weak value with each ensemble. Here, we present the simultaneous full complex quantification of two path weak values with a single ensemble in a Mach-Zehnder neutron interferometer. Magnetic fields, oscillating with different frequencies, change the energy state in each interferometer path. The time-dependent phase between the energy states distinctly marks each path. The resulting beating intensity modulation at the interferometer output gives both path weak values. For the present experiment, the weak values' absolute value and phase directly describe the observed amplitude and phase of the intensity modulation.

Scientific Reports•Oct 29, 2024•3 citations

Weak-to-Strong Measurement Transition with Thermal Instabilities: From Anomalous Amplification to Metrological Sensitivity

Marcos V. S. Lima, Carlos H. S. Vieira, Irismar G. da Paz +2 more

Quantum measurement is physically realized through a finite dynamical interaction between a system and a measuring apparatus, giving rise to a continuous transition from weak to strong regimes. While this crossover is well understood under ideal conditions, the combined role of thermal instabilities and pre- and post-selection open dynamics has not been systematically addressed. Here, we develop a generalized open-system framework to analyze the weak-to-strong measurement transition in the simultaneous presence of environmental decoherence and thermal noise. We model the probe as a thermal Gaussian state, explicitly incorporating temperature-dependent fluctuations in the measuring device, and include open-system evolution of the measured system prior to post-selection. By deriving the apparatus's final state, we show that the measurement statistics are modified in a nontrivial, highly sensitive manner by the temperature regime of the system's thermal instabilities, the probe's thermal properties, and the particular choice of pre- and post-selection. This approach allows us to characterize how thermal effects reshape the weak-value condition, the anomalous amplification, and the resulting metrological sensitivity, demonstrating the protocol's practical utility for precision measurements across the full measurement crossover.

quant-pharXiv:2604.28137•May 1, 2026•0 citations

Measuring which-path information with coupled electronic Mach-Zehnder interferometers

Justin Dressel, Yunjin Choi, Andrew N. Jordan

We theoretically investigate a generalized ``which-path'' measurement on an electronic Mach-Zehnder Interferometer (MZI) implemented via Coulomb coupling to a second electronic MZI acting as a detector. The use of contextual values, or generalized eigenvalues, enables the precise construction of which-path operator averages that are valid for any measurement strength from the available drain currents. The form of the contextual values provides direct physical insight about the measurement being performed, providing information about the correlation strength between system and detector, the measurement inefficiency, and the proper background removal. We find that the detector interferometer must display maximal wavelike behavior to optimally measure the particle-like which-path information in the system interferometer, demonstrating wave-particle complementarity between the system and detector. We also find that the degree of quantum erasure that can be achieved by conditioning on a specific detector drain is directly related to the ambiguity of the measurement. Finally, conditioning the which-path averages on a particular system drain using the zero-frequency cross correlations produces conditioned averages that can become anomalously large due to quantum interference; the weak-coupling limit of these conditioned averages can produce both weak and detector-dependent semiweak values.

arXiv:1105.2587•Physical Review B•Jan 23, 2012•29 citations
Measurements with variable system–detector interaction strength, ranging from weak to strong, have been recently reported in a number of electronic nanosystems. In several such instances many-body effects play a significant role. Here we consider the weak-to-strong crossover for a setup consisting of an electronic Mach–Zehnder interferometer, where a second interferometer is employed as a detector. In the context of a conditional which-path protocol, we define a generalized conditional value (GCV), and determine its full crossover between the regimes of weak and strong (projective) measurement. We find that the GCV has an oscillatory dependence on the system–detector interaction strength. These oscillations are a genuine many-body effect, and can be experimentally observed through the voltage dependence of cross current correlations.
Weak values provide a powerful framework for characterizing quantum systems. Their experimental extraction conventionally relies on weak conditioned von Neumann measurements, involving weak interactions and meter states that increase experimental complexity and often limit measurement efficiency. Here we introduce a method to fully characterize path weak-values in a generalized Mach-Zehnder interferometer employing neither meter states nor weak interactions. We experimentally demonstrate the technique in matter-wave interferometry. We identify anomalous weak values and, equivalently, negative quasiprobability distributions, which reflect the nonclassical behavior of the quantum system. The approach relies uniquely on intensity measurements at the output ports of the interferometer combined with controlled relative phase shifts between the paths. The absence of meter states enables considerable simplification of the setup and shorter measurement times, while preserving full access to weak values with comparable or increased accuracy. The scheme is directly applicable to a broad class of experiments involving two-level quantum systems.
Weak value (WV) protocols may lead to extreme expectation values that are larger than the corresponding orthodox expectation values. Recent works have proposed to implement this concept in nano-scale electronic systems. Here we address the issue of how one calibrates the setup in question, maximizes the measurement's sensitivity, and extracts distinctly large WVs. Our concrete setup consists of two Mach-Zehnder interferometers (MZIs): the "system" and the "detector". Such setups have already been implemented in experiment.
The statistical properties of the detection events constituting the interference fringes at the output of an interferometer are well-known. Nevertheless, there is still no unified view of what is happening to a quantum system inside an interferometer. Strong measurements of path operators destroy the interference effect. In weak measurements, an observable is weakly coupled to a pointer system and the resulting weak values quantify the observable by minimally disturbing the system. Previous which-way experiments with weak measurements could extract either the real or imaginary part of a single weak value with each ensemble. Here, we present the simultaneous full complex quantification of two path weak values with a single ensemble in a Mach-Zehnder neutron interferometer. Magnetic fields, oscillating with different frequencies, change the energy state in each interferometer path. The time-dependent phase between the energy states distinctly marks each path. The resulting beating intensity modulation at the interferometer output gives both path weak values. For the present experiment, the weak values' absolute value and phase directly describe the observed amplitude and phase of the intensity modulation.
Quantum measurement is physically realized through a finite dynamical interaction between a system and a measuring apparatus, giving rise to a continuous transition from weak to strong regimes. While this crossover is well understood under ideal conditions, the combined role of thermal instabilities and pre- and post-selection open dynamics has not been systematically addressed. Here, we develop a generalized open-system framework to analyze the weak-to-strong measurement transition in the simultaneous presence of environmental decoherence and thermal noise. We model the probe as a thermal Gaussian state, explicitly incorporating temperature-dependent fluctuations in the measuring device, and include open-system evolution of the measured system prior to post-selection. By deriving the apparatus's final state, we show that the measurement statistics are modified in a nontrivial, highly sensitive manner by the temperature regime of the system's thermal instabilities, the probe's thermal properties, and the particular choice of pre- and post-selection. This approach allows us to characterize how thermal effects reshape the weak-value condition, the anomalous amplification, and the resulting metrological sensitivity, demonstrating the protocol's practical utility for precision measurements across the full measurement crossover.
We theoretically investigate a generalized ``which-path'' measurement on an electronic Mach-Zehnder Interferometer (MZI) implemented via Coulomb coupling to a second electronic MZI acting as a detector. The use of contextual values, or generalized eigenvalues, enables the precise construction of which-path operator averages that are valid for any measurement strength from the available drain currents. The form of the contextual values provides direct physical insight about the measurement being performed, providing information about the correlation strength between system and detector, the measurement inefficiency, and the proper background removal. We find that the detector interferometer must display maximal wavelike behavior to optimally measure the particle-like which-path information in the system interferometer, demonstrating wave-particle complementarity between the system and detector. We also find that the degree of quantum erasure that can be achieved by conditioning on a specific detector drain is directly related to the ambiguity of the measurement. Finally, conditioning the which-path averages on a particular system drain using the zero-frequency cross correlations produces conditioned averages that can become anomalously large due to quantum interference; the weak-coupling limit of these conditioned averages can produce both weak and detector-dependent semiweak values.