Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1105.2587 · Physical Review B

Measuring which-path information with coupled electronic Mach-Zehnder interferometers

Justin Dressel, Yunjin Choi, Andrew N. Jordan

Published Jan 23, 2012• 29 citations
arXivHTMLPDF

Abstract

We theoretically investigate a generalized ``which-path'' measurement on an electronic Mach-Zehnder Interferometer (MZI) implemented via Coulomb coupling to a second electronic MZI acting as a detector. The use of contextual values, or generalized eigenvalues, enables the precise construction of which-path operator averages that are valid for any measurement strength from the available drain currents. The form of the contextual values provides direct physical insight about the measurement being performed, providing information about the correlation strength between system and detector, the measurement inefficiency, and the proper background removal. We find that the detector interferometer must display maximal wavelike behavior to optimally measure the particle-like which-path information in the system interferometer, demonstrating wave-particle complementarity between the system and detector. We also find that the degree of quantum erasure that can be achieved by conditioning on a specific detector drain is directly related to the ambiguity of the measurement. Finally, conditioning the which-path averages on a particular system drain using the zero-frequency cross correlations produces conditioned averages that can become anomalously large due to quantum interference; the weak-coupling limit of these conditioned averages can produce both weak and detector-dependent semiweak values.

DOI
10.1103/physrevb.85.045320

Related papers

Detection of Quantum Interference without an Interference Pattern

Iliya Esin, Alessandro Romito, Yuval Gefen

Quantum interference is typically detected through the dependence of the interference signal on certain parameters (path length, Aharonov-Bohm flux, etc.), which can be varied in a controlled manner. The destruction of interference by a which-path measurement is a paradigmatic manifestation of quantum effects. Here we report on a novel measurement protocol that realizes two objectives: (i) certifying that a measured signal is the result of interference avoiding the need to vary parameters of the underlying interferometer, and (ii) certifying that the interference signal at hand is of quantum nature. In particular, it yields a null outcome in the case of classical interference. Our protocol comprises measurements of cross-correlations between the readings of which-path weakly coupled detectors positioned at the respective interferometer's arms and the current in one of the interferometer's drains. We discuss its implementation with an experimentally available platform: an electronic Mach-Zehnder interferometer (MZI) coupled electrostatically to "detectors" (quantum point contacts).

arXiv:1910.13705•Physical Review Letters•Jul 10, 2020•6 citations

Anomalous weak values in a generalized Mach-Zehnder interferometer extracted directly from intensity measurements

Ismaele V. Masiello, Hartmut Lemmel, Andreas Dvorak +2 more

Weak values provide a powerful framework for characterizing quantum systems. Their experimental extraction conventionally relies on weak conditioned von Neumann measurements, involving weak interactions and meter states that increase experimental complexity and often limit measurement efficiency. Here we introduce a method to fully characterize path weak-values in a generalized Mach-Zehnder interferometer employing neither meter states nor weak interactions. We experimentally demonstrate the technique in matter-wave interferometry. We identify anomalous weak values and, equivalently, negative quasiprobability distributions, which reflect the nonclassical behavior of the quantum system. The approach relies uniquely on intensity measurements at the output ports of the interferometer combined with controlled relative phase shifts between the paths. The absence of meter states enables considerable simplification of the setup and shorter measurement times, while preserving full access to weak values with comparable or increased accuracy. The scheme is directly applicable to a broad class of experiments involving two-level quantum systems.

quant-pharXiv:2606.24798•npj Quantum Information•Jun 24, 2026•0 citations

Entanglement, Dephasing, and Phase Recovery via Cross-Correlation Measurements of Electrons

Izhar Neder, Moty Heiblum, D. Mahalu +1 more

Determination of the path taken by a quantum particle leads to a suppression of interference and to a classical behavior. We employ here a quantum "which path" detector to perform accurate path determination in a two-path Mach-Zehnder electron interferometer, leading to full suppression of the interference. Following the dephasing process we recover the interference by measuring the cross correlation between the interferometer and detector currents. Under our measurement conditions every interfering electron is dephased by approximately a single electron in the detector-leading to mutual entanglement of approximately single pairs of electrons.

arXiv:cond-mat/0607346•Physical Review Letters•Jan 16, 2007•122 citations

Complementarity via error-free measurement in a two-path interferometer

Yanjun Liu, Jing Lu, Lan Zhou

Abstract We study both wave-like behavior and particle-like behavior in a general Mach–Zehnder interferometer with an asymmetric beam splitter. An error-free measurement in the detector is used to extract the which-path information. The fringe visibility V and the which-path information I path are derived, their complementary relation V + I p a t h ⩽ 1 is found, and the condition for the equality is also presented.

arXiv:1611.00124•Laser Physics Letters•Mar 28, 2017•7 citations

Non-Gaussian Dephasing of an Electronic Mach-Zehnder Interferometer Coupled to "Which Path" Detector

Izhar Neder

A theoretical non-pertubative treatment is developed to explain the dephasing of electrons in the electronic Mach-Zehnder interferometer via interaction with a near-by partitioned electronic channel, which acts as a "which path" detector. The resulting formula reproduces the recant experimental behavior of the MZI interference visibility. By fitting the model to the experimental results, it is shown that the visibility is strongly influenced by merely ~3 detecting electrons, hence it reflects the Non-Gaussian properties behavior of the detector shot-noise.

arXiv:cond-mat/0610636•Oct 23, 2006•0 citations

Crossover between strong and weak measurement in interacting many-body systems

Iliya Esin, Alessandro Romito, Yaroslav M. Blanter +1 more

Measurements with variable system–detector interaction strength, ranging from weak to strong, have been recently reported in a number of electronic nanosystems. In several such instances many-body effects play a significant role. Here we consider the weak-to-strong crossover for a setup consisting of an electronic Mach–Zehnder interferometer, where a second interferometer is employed as a detector. In the context of a conditional which-path protocol, we define a generalized conditional value (GCV), and determine its full crossover between the regimes of weak and strong (projective) measurement. We find that the GCV has an oscillatory dependence on the system–detector interaction strength. These oscillations are a genuine many-body effect, and can be experimentally observed through the voltage dependence of cross current correlations.

arXiv:1409.4094•New Journal of Physics•Jan 8, 2016•3 citations
We theoretically investigate a generalized ``which-path'' measurement on an electronic Mach-Zehnder Interferometer (MZI) implemented via Coulomb coupling to a second electronic MZI acting as a detector. The use of contextual values, or generalized eigenvalues, enables the precise construction of which-path operator averages that are valid for any measurement strength from the available drain currents. The form of the contextual values provides direct physical insight about the measurement being performed, providing information about the correlation strength between system and detector, the measurement inefficiency, and the proper background removal. We find that the detector interferometer must display maximal wavelike behavior to optimally measure the particle-like which-path information in the system interferometer, demonstrating wave-particle complementarity between the system and detector. We also find that the degree of quantum erasure that can be achieved by conditioning on a specific detector drain is directly related to the ambiguity of the measurement. Finally, conditioning the which-path averages on a particular system drain using the zero-frequency cross correlations produces conditioned averages that can become anomalously large due to quantum interference; the weak-coupling limit of these conditioned averages can produce both weak and detector-dependent semiweak values.
Quantum interference is typically detected through the dependence of the interference signal on certain parameters (path length, Aharonov-Bohm flux, etc.), which can be varied in a controlled manner. The destruction of interference by a which-path measurement is a paradigmatic manifestation of quantum effects. Here we report on a novel measurement protocol that realizes two objectives: (i) certifying that a measured signal is the result of interference avoiding the need to vary parameters of the underlying interferometer, and (ii) certifying that the interference signal at hand is of quantum nature. In particular, it yields a null outcome in the case of classical interference. Our protocol comprises measurements of cross-correlations between the readings of which-path weakly coupled detectors positioned at the respective interferometer's arms and the current in one of the interferometer's drains. We discuss its implementation with an experimentally available platform: an electronic Mach-Zehnder interferometer (MZI) coupled electrostatically to "detectors" (quantum point contacts).
Weak values provide a powerful framework for characterizing quantum systems. Their experimental extraction conventionally relies on weak conditioned von Neumann measurements, involving weak interactions and meter states that increase experimental complexity and often limit measurement efficiency. Here we introduce a method to fully characterize path weak-values in a generalized Mach-Zehnder interferometer employing neither meter states nor weak interactions. We experimentally demonstrate the technique in matter-wave interferometry. We identify anomalous weak values and, equivalently, negative quasiprobability distributions, which reflect the nonclassical behavior of the quantum system. The approach relies uniquely on intensity measurements at the output ports of the interferometer combined with controlled relative phase shifts between the paths. The absence of meter states enables considerable simplification of the setup and shorter measurement times, while preserving full access to weak values with comparable or increased accuracy. The scheme is directly applicable to a broad class of experiments involving two-level quantum systems.
Determination of the path taken by a quantum particle leads to a suppression of interference and to a classical behavior. We employ here a quantum "which path" detector to perform accurate path determination in a two-path Mach-Zehnder electron interferometer, leading to full suppression of the interference. Following the dephasing process we recover the interference by measuring the cross correlation between the interferometer and detector currents. Under our measurement conditions every interfering electron is dephased by approximately a single electron in the detector-leading to mutual entanglement of approximately single pairs of electrons.
A theoretical non-pertubative treatment is developed to explain the dephasing of electrons in the electronic Mach-Zehnder interferometer via interaction with a near-by partitioned electronic channel, which acts as a "which path" detector. The resulting formula reproduces the recant experimental behavior of the MZI interference visibility. By fitting the model to the experimental results, it is shown that the visibility is strongly influenced by merely ~3 detecting electrons, hence it reflects the Non-Gaussian properties behavior of the detector shot-noise.
Measurements with variable system–detector interaction strength, ranging from weak to strong, have been recently reported in a number of electronic nanosystems. In several such instances many-body effects play a significant role. Here we consider the weak-to-strong crossover for a setup consisting of an electronic Mach–Zehnder interferometer, where a second interferometer is employed as a detector. In the context of a conditional which-path protocol, we define a generalized conditional value (GCV), and determine its full crossover between the regimes of weak and strong (projective) measurement. We find that the GCV has an oscillatory dependence on the system–detector interaction strength. These oscillations are a genuine many-body effect, and can be experimentally observed through the voltage dependence of cross current correlations.