Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1405.6480

Single particle microscopy with nanometer resolution

Jacob, Georg, Karin Groot-Berning, Wolf, Sebastian, Stefan Ulm, Luc Couturier, Ulrich Poschinger, Ferdinand Schmidt‐Kaler, Kilian Singer

Published May 26, 2014• 7 citations
arXivHTMLPDF

Abstract

We experimentally demonstrate nanoscopic transmission microscopy relying on a deterministic single particle source. This increases the signal-to-noise ratio with respect to conventional microscopy methods, which employ Poissonian particle sources. We use laser-cooled ions extracted from a Paul trap, and demonstrate remote imaging of transmissive objects with a resolution of 8.6 $\pm$ 2.0nm and a minimum two-sample deviation of the beam position of 1.5nm. Detector dark counts can be suppressed by 6 orders of magnitudes through gating by the extraction event. The deterministic nature of our source enables an information-gain driven approach to imaging. We demonstrate this by performing efficient beam characterization based on a Bayes experiment design method.

DOI
10.48550/arxiv.1405.6480

Related papers

Transmission Microscopy with Nanometer Resolution Using a Deterministic Single Ion Source

Georg Jacob, Karin Groot-Berning, Sebastian Wolf +6 more

We realize a single particle microscope by using deterministically extracted laser-cooled ^{40}Ca^{+} ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions to a spot size of 5.8±1.0 nm and a minimum two-sample deviation of the beam position of 1.5 nm in the focal plane. The deterministic source, even when used in combination with an imperfect detector, gives rise to a fivefold increase in the signal-to-noise ratio as compared with conventional Poissonian sources. Gating of the detector signal by the extraction event suppresses dark counts by 6 orders of magnitude. We implement a Bayes experimental design approach to microscopy in order to maximize the gain in spatial information. We demonstrate this method by determining the position of a 1 μm circular hole structure to a precision of 2.7 nm using only 579 probe particles.

arXiv:1512.00347•Physical Review Letters•Jul 20, 2016•58 citations

Maximizing the Information Gain of a Single Ion Microscope using Bayes Experimental Design

Georg Jacob, Karin Groot-Berning, G Poschinger Ulrich +2 more

We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 1, 2016•1 citation

Maximizing the information gain of a single ion microscope using bayes experimental design

Georg Jacob, Karin Groot-Berning, Ulrich G. Poschinger +2 more

We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.

arXiv:1605.05071•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•1 citation

Optimised focusing ion optics for an ultracold deterministic single ion source targeting nm resolution

Robert Fickler, Wolfgang Schnitzler, Norbert M. Linke +2 more

Using a segmented ion trap with mK laser-cooled ions we have realised a novel single ion source which can deterministically deliver a wide range of ion species, isotopes or ionic molecules [Schnitzler et al. Phys. Rev. Lett. 2009, 102, 070501]. Experimental data is discussed in detail and compared with numerical simulations of ion trajectories. For the novel ion source we numerically investigate the influence of various extraction parameters on fluctuations in velocity and position of the beam. We present specialised ion optics and show from numerical simulations that a nm spatial resolution is achievable. The Paul trap, which is used as a single ion source, together with the presented ion optics, constitutes a promising candidate for a deterministic ion implantation method for applications in solid state quantum computing or classical nano-electronic devices.

arXiv:0903.3425•Journal of Modern Optics•Aug 19, 2009•5 citations

Deterministic Ultracold Ion Source Targeting the Heisenberg Limit

Wolfgang Schnitzler, Norbert M. Linke, Robert Fickler +3 more

The major challenges to fabricate quantum processors and future nano-solid-state devices are material modification techniques with nanometer resolution and suppression of statistical fluctuations of dopants or qubit carriers. Based on a segmented ion trap with mK laser-cooled ions we have realized a deterministic single-ion source which could operate with a huge range of sympathetically cooled ion species, isotopes or ionic molecules. We have deterministically extracted a predetermined number of ions on demand and have measured a longitudinal velocity uncertainty of 6.3 m/s and a spatial beam divergence of 600 microrad. We show in numerical simulations that if the ions are cooled to the motional ground state (Heisenberg limit) nanometer spatial resolution can be achieved.

arXiv:0902.0456•Physical Review Letters•Feb 19, 2009•75 citations

Super-resolution microscopy of single atoms in optical lattices

Andrea Alberti, Carsten Robens, Wolfgang Alt +5 more

We report on image processing techniques and experimental procedures to determine the lattice-site positions of single atoms in an optical lattice with high reliability, even for limited acquisition time or optical resolution. Determining the positions of atoms beyond the diffraction limit relies on parametric deconvolution in close analogy to methods employed in super-resolution microscopy. We develop a deconvolution method that makes effective use of the prior knowledge of the optical transfer function, noise properties, and discreteness of the optical lattice. We show that accurate knowledge of the image formation process enables a dramatic improvement on the localization reliability. This allows us to demonstrate super-resolution of the atoms' position in closely packed ensembles where the separation between particles cannot be directly optically resolved. Furthermore, we demonstrate experimental methods to precisely reconstruct the point spread function with sub-pixel resolution from fluorescence images of single atoms, and we give a mathematical foundation thereof. We also discuss discretized image sampling in pixel detectors and provide a quantitative model of noise sources in electron multiplying CCD cameras. The techniques developed here are not only beneficial to neutral atom experiments, but could also be employed to improve the localization precision of trapped ions for ultra precise force sensing.

arXiv:1512.07329•New Journal of Physics•May 6, 2016•69 citations
We experimentally demonstrate nanoscopic transmission microscopy relying on a deterministic single particle source. This increases the signal-to-noise ratio with respect to conventional microscopy methods, which employ Poissonian particle sources. We use laser-cooled ions extracted from a Paul trap, and demonstrate remote imaging of transmissive objects with a resolution of 8.6 ±\pm± 2.0nm and a minimum two-sample deviation of the beam position of 1.5nm. Detector dark counts can be suppressed by 6 orders of magnitudes through gating by the extraction event. The deterministic nature of our source enables an information-gain driven approach to imaging. We demonstrate this by performing efficient beam characterization based on a Bayes experiment design method.
We realize a single particle microscope by using deterministically extracted laser-cooled ^{40}Ca^{+} ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions to a spot size of 5.8±1.0 nm and a minimum two-sample deviation of the beam position of 1.5 nm in the focal plane. The deterministic source, even when used in combination with an imperfect detector, gives rise to a fivefold increase in the signal-to-noise ratio as compared with conventional Poissonian sources. Gating of the detector signal by the extraction event suppresses dark counts by 6 orders of magnitude. We implement a Bayes experimental design approach to microscopy in order to maximize the gain in spatial information. We demonstrate this method by determining the position of a 1 μm circular hole structure to a precision of 2.7 nm using only 579 probe particles.
We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.
We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.
Using a segmented ion trap with mK laser-cooled ions we have realised a novel single ion source which can deterministically deliver a wide range of ion species, isotopes or ionic molecules [Schnitzler et al. Phys. Rev. Lett. 2009, 102, 070501]. Experimental data is discussed in detail and compared with numerical simulations of ion trajectories. For the novel ion source we numerically investigate the influence of various extraction parameters on fluctuations in velocity and position of the beam. We present specialised ion optics and show from numerical simulations that a nm spatial resolution is achievable. The Paul trap, which is used as a single ion source, together with the presented ion optics, constitutes a promising candidate for a deterministic ion implantation method for applications in solid state quantum computing or classical nano-electronic devices.
The major challenges to fabricate quantum processors and future nano-solid-state devices are material modification techniques with nanometer resolution and suppression of statistical fluctuations of dopants or qubit carriers. Based on a segmented ion trap with mK laser-cooled ions we have realized a deterministic single-ion source which could operate with a huge range of sympathetically cooled ion species, isotopes or ionic molecules. We have deterministically extracted a predetermined number of ions on demand and have measured a longitudinal velocity uncertainty of 6.3 m/s and a spatial beam divergence of 600 microrad. We show in numerical simulations that if the ions are cooled to the motional ground state (Heisenberg limit) nanometer spatial resolution can be achieved.
We report on image processing techniques and experimental procedures to determine the lattice-site positions of single atoms in an optical lattice with high reliability, even for limited acquisition time or optical resolution. Determining the positions of atoms beyond the diffraction limit relies on parametric deconvolution in close analogy to methods employed in super-resolution microscopy. We develop a deconvolution method that makes effective use of the prior knowledge of the optical transfer function, noise properties, and discreteness of the optical lattice. We show that accurate knowledge of the image formation process enables a dramatic improvement on the localization reliability. This allows us to demonstrate super-resolution of the atoms' position in closely packed ensembles where the separation between particles cannot be directly optically resolved. Furthermore, we demonstrate experimental methods to precisely reconstruct the point spread function with sub-pixel resolution from fluorescence images of single atoms, and we give a mathematical foundation thereof. We also discuss discretized image sampling in pixel detectors and provide a quantitative model of noise sources in electron multiplying CCD cameras. The techniques developed here are not only beneficial to neutral atom experiments, but could also be employed to improve the localization precision of trapped ions for ultra precise force sensing.