Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1401.1288 · New Journal of Physics

Accelerating the averaging rate of atomic ensemble clock stability using atomic phase lock

Nobuyasu Shiga, Michiaki Mizuno, Kohta Kido, Piyaphat Phoonthong, K. Okada

Published Jul 22, 2014• 8 citations
arXivHTMLPDF

Abstract

We experimentally demonstrated that the stability of an atomic clock improves at its fastest rate τ −1 (where τ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms in a single trap (an atomic phase lock). For this demonstration, we developed a simple method that repeatedly monitors the atomic phase while retaining its coherence by observing only a portion of the whole ion cloud. Using this new method, we measured the continuous phase over three measurement cycles, and thereby improved the stability scaling from to τ −1 during the three measurement cycles. This simple method provides a path by which atomic clocks can approach a quantum projection noise limit, even when the measurement noise is dominated by the technical noise.

DOI
10.1088/1367-2630/16/7/073029

Related papers

Phase Locking a Clock Oscillator to a Coherent Atomic Ensemble

Ralf Kohlhaas, Andréa D Bertoldi, Etienne Cantin +3 more

Time measurements and navigation rely on atomic interferometers and atomic clocks. A new technique can improve the stability of such clocks by coupling a classical oscillator to an ensemble of atoms in a superposition state using repeated, coherence-preserving measurements.

arXiv:1501.03709•Physical Review X•Apr 27, 2015•57 citations

Overcoming the quantum projection noise (QPN) limit without preparation of the spin-squeezed state

Nobuyasu Shiga, Makoto Takeuchi

Atomic clocks have reached the Quantum Projection Noise (QPN) limit of stability and it has been proposed to use the entangled atomic ensemble in order to overcome the QPN limit. We have proposed a new method to lock the phase of the Local Oscillator (LO) to the atomic phase and call, "atomic phase lock (APL)." This APL could possibly overcome the QPN limit without need of preparing the entangled atomic ensemble. Traditional Ramsey method destroys the coherence of the atomic spin due to the projection measurement at each cycle. This destruction and initialization of the phase at each cycle introduce additional noise and the performance of the atomic clock is limited at the white frequency noise level. APL employs dispersion measurements, i.e. Faraday rotation, in order to measure the phase difference without destroying the atomic phase. By repeating the measurement cycle with sufficiently small dead time, one can suppress the LO noise down to white phase noise level, achieving the τ-1 dependence of the Allan variance that can eventually overcome the QPN limit in long term. We are preparing a proof-of-principle experiment using the ensemble of trapped 171Yb+ ions with hyperfine splitting (12.6 GHz) as a clock transition and report the current status of the experiment as well.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations

Efficient Atomic Clocks Operated with Several Atomic Ensembles

Johannes Borregaard, Anders Søndberg Sørensen

Atomic clocks are typically operated by locking a local oscillator (LO) to a single atomic ensemble. In this Letter, we propose a scheme where the LO is locked to several atomic ensembles instead of one. This results in an exponential improvement compared to the conventional method and provides a stability of the clock scaling as (αN)(-m/2) with N being the number of atoms in each of the m ensembles and α a constant depending on the protocol being used to lock the LO.

arXiv:1304.5944•Physical Review Letters•Aug 27, 2013•67 citations

Stability of Atomic Clocks Based on Entangled Atoms

Axel André, Anders Søndberg Sørensen, Mikhail D. Lukin

We analyze the effect of realistic noise sources for an atomic clock consisting of a local oscillator that is actively locked to a spin-squeezed (entangled) ensemble of N atoms. We show that the use of entangled states can lead to an improvement of the long-term stability of the clock when the measurement is limited by decoherence associated with instability of the local oscillator combined with fluctuations in the atomic ensemble's Bloch vector. Atomic states with a moderate degree of entanglement yield the maximal clock stability, resulting in an improvement that scales as N(1/6) compared to the atomic shot noise level.

arXiv:quant-ph/0401130•Physical Review Letters•Jun 7, 2004•157 citations

Locking the local oscillator phase to the atomic phase via weak measurement

Nobuyasu Shiga, Makoto Takeuchi

We propose a new method to reduce the frequency noise of a Local Oscillator (LO) to the level of white phase noise by maintaining (not destroying by projective measurement) the coherence of the ensemble pseudo-spin of atoms over many measurement cycles. This scheme uses weak measurement to monitor the phase in Ramsey method and repeat the cycle without initialization of phase and we call, "atomic phase lock (APL)" in this paper. APL will achieve white phase noise as long as the noise accumulated during dead time and the decoherence are smaller than the measurement noise. A numerical simulation confirms that with APL, Allan deviation is averaged down at a maximum rate that is proportional to the inverse of total measurement time, tau^-1. In contrast, the current atomic clocks that use projection measurement suppress the noise only down to the level of white frequency, in which case Allan deviation scales as tau^-1/2. Faraday rotation is one of the possible ways to realize weak measurement for APL. We evaluate the strength of Faraday rotation with 171Yb+ ions trapped in a linear rf-trap and discuss the performance of APL. The main source of the decoherence is a spontaneous emission induced by the probe beam for Faraday rotation measurement. One can repeat the Faraday rotation measurement until the decoherence become comparable to the SNR of measurement. We estimate this number of cycles to be ~100 cycles for a realistic experimental parameter.

•Jan 1, 2012•32 citations

Locking the local oscillator phase to the atomic phase via weak measurement

N Shiga, M Takeuchi

A new method is proposed to reduce the frequency noise of a local oscillator to the level of white phase noise by maintaining (not destroying by projective measurement) the coherence of the ensemble pseudo-spin of atoms over many measurement cycles. This method, which we call 'atomic phase lock (APL)', uses weak measurement to monitor the phase in the Ramsey method and repeat the cycle without initialization of the phase. APL will achieve white phase noise as long as the noise accumulated during dead time and the decoherence are smaller than the measurement noise. A numerical simulation confirmed that with APL, the Allan deviation is averaged down at a maximum rate that is proportional to the inverse of the total measurement time, τ −1 . In contrast, current atomic clocks that use projection measurement suppress the noise only to the white frequency noise level, in which case the Allan deviation scales as τ −1/2 . Faraday rotation is one way to achieve weak measurement for APL. The strength of Faraday rotation with 171 Yb + ions trapped in a linear rf-trap is evaluated, and the performance of APL is discussed. The main source of decoherence is a spontaneous emission, induced by the probe beam for Faraday rotation measurement. The Faraday rotation measurement can be repeated until the decoherence becomes comparable to the signal-to-noise ratio of the measurement. The number of cycles for a realistic experimental parameter is estimated to be ∼100.

arXiv:1107.5176•New Journal of Physics•Feb 15, 2012•34 citations
We experimentally demonstrated that the stability of an atomic clock improves at its fastest rate τ −1 (where τ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms in a single trap (an atomic phase lock). For this demonstration, we developed a simple method that repeatedly monitors the atomic phase while retaining its coherence by observing only a portion of the whole ion cloud. Using this new method, we measured the continuous phase over three measurement cycles, and thereby improved the stability scaling from to τ −1 during the three measurement cycles. This simple method provides a path by which atomic clocks can approach a quantum projection noise limit, even when the measurement noise is dominated by the technical noise.
Atomic clocks have reached the Quantum Projection Noise (QPN) limit of stability and it has been proposed to use the entangled atomic ensemble in order to overcome the QPN limit. We have proposed a new method to lock the phase of the Local Oscillator (LO) to the atomic phase and call, "atomic phase lock (APL)." This APL could possibly overcome the QPN limit without need of preparing the entangled atomic ensemble. Traditional Ramsey method destroys the coherence of the atomic spin due to the projection measurement at each cycle. This destruction and initialization of the phase at each cycle introduce additional noise and the performance of the atomic clock is limited at the white frequency noise level. APL employs dispersion measurements, i.e. Faraday rotation, in order to measure the phase difference without destroying the atomic phase. By repeating the measurement cycle with sufficiently small dead time, one can suppress the LO noise down to white phase noise level, achieving the τ-1 dependence of the Allan variance that can eventually overcome the QPN limit in long term. We are preparing a proof-of-principle experiment using the ensemble of trapped 171Yb+ ions with hyperfine splitting (12.6 GHz) as a clock transition and report the current status of the experiment as well.
We analyze the effect of realistic noise sources for an atomic clock consisting of a local oscillator that is actively locked to a spin-squeezed (entangled) ensemble of N atoms. We show that the use of entangled states can lead to an improvement of the long-term stability of the clock when the measurement is limited by decoherence associated with instability of the local oscillator combined with fluctuations in the atomic ensemble's Bloch vector. Atomic states with a moderate degree of entanglement yield the maximal clock stability, resulting in an improvement that scales as N(1/6) compared to the atomic shot noise level.
We propose a new method to reduce the frequency noise of a Local Oscillator (LO) to the level of white phase noise by maintaining (not destroying by projective measurement) the coherence of the ensemble pseudo-spin of atoms over many measurement cycles. This scheme uses weak measurement to monitor the phase in Ramsey method and repeat the cycle without initialization of phase and we call, "atomic phase lock (APL)" in this paper. APL will achieve white phase noise as long as the noise accumulated during dead time and the decoherence are smaller than the measurement noise. A numerical simulation confirms that with APL, Allan deviation is averaged down at a maximum rate that is proportional to the inverse of total measurement time, tau^-1. In contrast, the current atomic clocks that use projection measurement suppress the noise only down to the level of white frequency, in which case Allan deviation scales as tau^-1/2. Faraday rotation is one of the possible ways to realize weak measurement for APL. We evaluate the strength of Faraday rotation with 171Yb+ ions trapped in a linear rf-trap and discuss the performance of APL. The main source of the decoherence is a spontaneous emission induced by the probe beam for Faraday rotation measurement. One can repeat the Faraday rotation measurement until the decoherence become comparable to the SNR of measurement. We estimate this number of cycles to be ~100 cycles for a realistic experimental parameter.
A new method is proposed to reduce the frequency noise of a local oscillator to the level of white phase noise by maintaining (not destroying by projective measurement) the coherence of the ensemble pseudo-spin of atoms over many measurement cycles. This method, which we call 'atomic phase lock (APL)', uses weak measurement to monitor the phase in the Ramsey method and repeat the cycle without initialization of the phase. APL will achieve white phase noise as long as the noise accumulated during dead time and the decoherence are smaller than the measurement noise. A numerical simulation confirmed that with APL, the Allan deviation is averaged down at a maximum rate that is proportional to the inverse of the total measurement time, τ −1 . In contrast, current atomic clocks that use projection measurement suppress the noise only to the white frequency noise level, in which case the Allan deviation scales as τ −1/2 . Faraday rotation is one way to achieve weak measurement for APL. The strength of Faraday rotation with 171 Yb + ions trapped in a linear rf-trap is evaluated, and the performance of APL is discussed. The main source of decoherence is a spontaneous emission, induced by the probe beam for Faraday rotation measurement. The Faraday rotation measurement can be repeated until the decoherence becomes comparable to the signal-to-noise ratio of the measurement. The number of cycles for a realistic experimental parameter is estimated to be ∼100.