Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1308.0763 · AIP Advances

Jitter analysis of a superconducting nanowire single photon detector

Lixing You, Xiaoyan Yang, Yuhao He, Wenxing Zhang, Dengkuan Liu, Weijun Zhang, Lu Zhang, Ling Zhang, Xiaoyu Liu, Sijing Chen, Zhen Wang, Xiaoming Xie

Published Jul 1, 2013• 135 citations
arXivHTMLPDF

Abstract

Jitter is one of the key parameters for a superconducting nanowire single photon detector (SNSPD). Using an optimized time-correlated single photon counting system for jitter measurement, we extensively studied the dependence of system jitter on the bias current and working temperature. The signal-to-noise ratio of the single-photon-response pulse was proven to be an important factor in system jitter. The final system jitter was reduced to 18 ps by using a high-critical-current SNSPD, which showed an intrinsic SNSPD jitter of 15 ps. A laser ranging experiment using a 15-ps SNSPD achieved a record depth resolution of 3 mm at a wavelength of 1550 nm.

DOI
10.1063/1.4817581

Related papers

Improving the timing jitter of a superconducting nanowire single-photon detection system

Junjie Wu, Lixing You, Sijing Chen +5 more

Low timing jitter is a unique merit of superconducting nanowire single-photon detectors (SNSPDs) for time-correlated applications. Quantitative analysis was performed for the SNSPD system. Aided by an oscilloscope with an optimal signal amplitude, we were able to measure a full width at half-maximum system timing jitter as low as 14.2 ps for a high-switching-current SNSPD using a room-temperature low-noise amplifier. When using a time-correlated single-photon counting module, the system timing jitter was 17.3 ps. The detector's intrinsic timing jitter was estimated at ∼12.0 ps.

Applied Optics•Mar 6, 2017•96 citations

Intrinsically-limited timing jitter in molybdenum silicide superconducting nanowire single-photon detectors

Misael Caloz, Boris A. Korzh, Edward Ramirez +5 more

Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) has delivered excellent performance and has had a great impact on a range of research fields. The timing jitter, which denotes the temporal resolution of the detection, is a crucial parameter for many applications. Despite extensive work since their apparition, the lowest jitter achievable with SNSPDs is still not clear, and the origin of the intrinsic limits is not fully understood. Understanding its intrinsic behavior and limits is a mandatory step toward improvements. Here, we report our experimental study on the intrinsically-limited timing jitter in molybdenum silicide SNSPDs. We show that to reach intrinsic jitter, crucial properties such as the latching current and the kinetic inductance of the devices have to be understood. The dependence on the nanowire thickness and the energy dependence of the intrinsic jitter are quantified, and the origin of the limits is exhibited. System timing jitter of 6.0 ps at 532 nm and 10.6 ps at 1550 nm photon wavelength has been obtained.

•Jan 1, 2019•21 citations

Intrinsically-limited timing jitter in molybdenum silicide superconducting nanowire single-photon detectors

Misael Caloz, Boris A. Korzh, Edward Ramirez +5 more

Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) has delivered excellent performance and has had a great impact on a range of research fields. The timing jitter, which denotes the temporal resolution of the detection, is a crucial parameter for many applications. Despite extensive work since their apparition, the lowest jitter achievable with SNSPDs is still not clear, and the origin of the intrinsic limits is not fully understood. Understanding its intrinsic behavior and limits is a mandatory step toward improvements. Here, we report our experimental study on the intrinsically-limited timing jitter in molybdenum silicide SNSPDs. We show that to reach intrinsic jitter, crucial properties such as the latching current and the kinetic inductance of the devices have to be understood. The dependence on the nanowire thickness and the energy dependence of the intrinsic jitter are quantified, and the origin of the limits is exhibited. System timing jitter of 6.0 ps at 532 nm and 10.6 ps at 1550 nm photon wavelength has been obtained.

arXiv:1906.02073•Journal of Applied Physics•Oct 22, 2019•26 citations

50 µm diameter superconducting nanowire single-photon detector with sub-17 ps timing jitter and high efficiency for visible wavelengths (Conference Presentation)

Jin Chang, Iman Esmaeil Zadeh

Superconducting nanowire single photon detectors (SNSPDs) have demonstrated advantages over traditional detectors in many fields [1]. Most fiber-coupled SNSPDs are coupled to single mode fibers, limiting their usability for applications where large surface area detectors are needed, for example fluorescence detection and satellite-based quantum communication [2][3]. Other important requirements for many applications are broadband detection efficiency, and low timing jitter [4]. So far, the increased meander length of multimode detectors, and the therefore increased kinetic inductance and number of imperfections due to film inhomogeneities have limited the timing jitter [5]. Moreover, combining low timing jitter with high detection efficiency and low dark count rate in one device is challenging due to the tradeoffs between different properties of SNSPDs [6]. In this paper, we achieved high efficiency and strong saturation over a broad wavelength range with a low timing jitter of 16.99 ps while maintaining a low dark count rate of < 0.2 Hz for an SNSPD coupled to a 50 µm core multimode fiber. To enhance the broadband absorption from 405 nm to 830 nm, detectors were fabricated on an optimized SiO2 cavity and Aluminum mirror. The geometry of the nanowire was also tuned to reach a good internal saturation of efficiency over the visible/NIR range but also to carry high current to get a large signal. Furthermore, a cryogenic readout amplifier was optimized to improve the signal to noise ratio and thus lead to high time resolution. Our devices can be readily used to enable higher resolution and faster quantum optics, bio-imaging, laser ranging and other optical experiments.

Quantum Optics and Photon Counting•May 13, 2019•0 citations

A superconducting nanowire single-photon detector system for single-photon source characterization

Catherine R. M. Fitzpatrick, Chandra M. Natarajan, Ryan E. Warburton +8 more

Single-photon sources and detectors are key enabling technologies for photonics in quantum information science and technology (QIST). QIST applications place high-level demands on the performance of sources and detectors; it is therefore essential that their properties can be characterized accurately. Superconducting nanowire single-photon detectors (SNSPDs) have spectral sensitivity from visible to beyond 2 μm in wavelength, picosecond timing resolution (Jitter <100 ps FWHM) and the capacity to operate ungated with low dark counts (<1 kHz). This facilitates data acquisition at high rates with an excellent signal-to-noise ratio. We report on the construction and characterization of a two-channel SNSPD system. The detectors are mounted in a closed-cycle refrigerator, which eliminates reliance on liquid cryogens. Our specification was to deliver a system with 1% efficiency in both channels at a wavelength of 1310 nm with 1 kHz dark count rate. A full width at half maximum timing jitter of less than 90 ps is achieved in both channels. The system will be used to detect individual photons generated by quantum-optical sources at telecom wavelengths. Examples include single-photon sources based on quantum dots (emitting at 1310 nm). The SNSPD system's spectral sensitivity and timing resolution make it suited to characterization of such sources, and to wider QIST applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 20, 2010•0 citations

Minimal Timing Jitter in Superconducting Nanowire Single-Photon Detectors

Denis Yu. Vodolazov

The results of this theoretical study are important for applications dealing with superconducting nanowire single-photon detectors (SNSPDs), which include quantum information processing. The author shows that the variation in delay time ${\ensuremath{\tau}}_{d}$ (timing jitter) of the voltage response after absorption of a single photon, connected to either position-dependent response or variation in the energy deposited to electrons, could be as small as 1 ps when the current in the superconducting strip approaches the depairing current. Reducing this jitter is a main topic of SNSPD research, and understanding the origins of these variations is necessary to that end.

arXiv:1807.07709•Physical Review Applied•Jan 9, 2019•32 citations
Jitter is one of the key parameters for a superconducting nanowire single photon detector (SNSPD). Using an optimized time-correlated single photon counting system for jitter measurement, we extensively studied the dependence of system jitter on the bias current and working temperature. The signal-to-noise ratio of the single-photon-response pulse was proven to be an important factor in system jitter. The final system jitter was reduced to 18 ps by using a high-critical-current SNSPD, which showed an intrinsic SNSPD jitter of 15 ps. A laser ranging experiment using a 15-ps SNSPD achieved a record depth resolution of 3 mm at a wavelength of 1550 nm.
Low timing jitter is a unique merit of superconducting nanowire single-photon detectors (SNSPDs) for time-correlated applications. Quantitative analysis was performed for the SNSPD system. Aided by an oscilloscope with an optimal signal amplitude, we were able to measure a full width at half-maximum system timing jitter as low as 14.2 ps for a high-switching-current SNSPD using a room-temperature low-noise amplifier. When using a time-correlated single-photon counting module, the system timing jitter was 17.3 ps. The detector's intrinsic timing jitter was estimated at ∼12.0 ps.
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) has delivered excellent performance and has had a great impact on a range of research fields. The timing jitter, which denotes the temporal resolution of the detection, is a crucial parameter for many applications. Despite extensive work since their apparition, the lowest jitter achievable with SNSPDs is still not clear, and the origin of the intrinsic limits is not fully understood. Understanding its intrinsic behavior and limits is a mandatory step toward improvements. Here, we report our experimental study on the intrinsically-limited timing jitter in molybdenum silicide SNSPDs. We show that to reach intrinsic jitter, crucial properties such as the latching current and the kinetic inductance of the devices have to be understood. The dependence on the nanowire thickness and the energy dependence of the intrinsic jitter are quantified, and the origin of the limits is exhibited. System timing jitter of 6.0 ps at 532 nm and 10.6 ps at 1550 nm photon wavelength has been obtained.
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) has delivered excellent performance and has had a great impact on a range of research fields. The timing jitter, which denotes the temporal resolution of the detection, is a crucial parameter for many applications. Despite extensive work since their apparition, the lowest jitter achievable with SNSPDs is still not clear, and the origin of the intrinsic limits is not fully understood. Understanding its intrinsic behavior and limits is a mandatory step toward improvements. Here, we report our experimental study on the intrinsically-limited timing jitter in molybdenum silicide SNSPDs. We show that to reach intrinsic jitter, crucial properties such as the latching current and the kinetic inductance of the devices have to be understood. The dependence on the nanowire thickness and the energy dependence of the intrinsic jitter are quantified, and the origin of the limits is exhibited. System timing jitter of 6.0 ps at 532 nm and 10.6 ps at 1550 nm photon wavelength has been obtained.
Superconducting nanowire single photon detectors (SNSPDs) have demonstrated advantages over traditional detectors in many fields [1]. Most fiber-coupled SNSPDs are coupled to single mode fibers, limiting their usability for applications where large surface area detectors are needed, for example fluorescence detection and satellite-based quantum communication [2][3]. Other important requirements for many applications are broadband detection efficiency, and low timing jitter [4]. So far, the increased meander length of multimode detectors, and the therefore increased kinetic inductance and number of imperfections due to film inhomogeneities have limited the timing jitter [5]. Moreover, combining low timing jitter with high detection efficiency and low dark count rate in one device is challenging due to the tradeoffs between different properties of SNSPDs [6]. In this paper, we achieved high efficiency and strong saturation over a broad wavelength range with a low timing jitter of 16.99 ps while maintaining a low dark count rate of < 0.2 Hz for an SNSPD coupled to a 50 µm core multimode fiber. To enhance the broadband absorption from 405 nm to 830 nm, detectors were fabricated on an optimized SiO2 cavity and Aluminum mirror. The geometry of the nanowire was also tuned to reach a good internal saturation of efficiency over the visible/NIR range but also to carry high current to get a large signal. Furthermore, a cryogenic readout amplifier was optimized to improve the signal to noise ratio and thus lead to high time resolution. Our devices can be readily used to enable higher resolution and faster quantum optics, bio-imaging, laser ranging and other optical experiments.
Single-photon sources and detectors are key enabling technologies for photonics in quantum information science and technology (QIST). QIST applications place high-level demands on the performance of sources and detectors; it is therefore essential that their properties can be characterized accurately. Superconducting nanowire single-photon detectors (SNSPDs) have spectral sensitivity from visible to beyond 2 μm in wavelength, picosecond timing resolution (Jitter <100 ps FWHM) and the capacity to operate ungated with low dark counts (<1 kHz). This facilitates data acquisition at high rates with an excellent signal-to-noise ratio. We report on the construction and characterization of a two-channel SNSPD system. The detectors are mounted in a closed-cycle refrigerator, which eliminates reliance on liquid cryogens. Our specification was to deliver a system with 1% efficiency in both channels at a wavelength of 1310 nm with 1 kHz dark count rate. A full width at half maximum timing jitter of less than 90 ps is achieved in both channels. The system will be used to detect individual photons generated by quantum-optical sources at telecom wavelengths. Examples include single-photon sources based on quantum dots (emitting at 1310 nm). The SNSPD system's spectral sensitivity and timing resolution make it suited to characterization of such sources, and to wider QIST applications.
The results of this theoretical study are important for applications dealing with superconducting nanowire single-photon detectors (SNSPDs), which include quantum information processing. The author shows that the variation in delay time ${\ensuremath{\tau}}_{d}$ (timing jitter) of the voltage response after absorption of a single photon, connected to either position-dependent response or variation in the energy deposited to electrons, could be as small as 1 ps when the current in the superconducting strip approaches the depairing current. Reducing this jitter is a main topic of SNSPD research, and understanding the origins of these variations is necessary to that end.