Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1305.6769 · Physical Review A

Optimizing the use of detector arrays for measuring intensity correlations of photon pairs

D. S. Tasca, M. Edgar, Frauke Izdebski, Gerald S. Buller, Miles J. Padgett

Published Jul 11, 2013• 26 citations
arXivHTMLPDF

Abstract

Intensity correlation measurements form the basis of many experiments based on spontaneous parametric down-conversion. In the most common situation, two single-photon avalanche diodes and coincidence electronics are used in the detection of the photon pairs, and the coincidence count distributions are measured by making use of some scanning procedure. Here we analyze the measurement of intensity correlations using multielement detector arrays. By considering the detector parameters such as the detection and noise probabilities, we found that the mean number of detected photons that maximizes the visibility of the two-photon correlations is approximately equal to the mean number of noise events in the detector array. We provide expressions predicting the strength of the measured intensity correlations as a function of the detector parameters and on the mean number of detected photons. We experimentally test our predictions by measuring far-field intensity correlations of spontaneous parametric down-conversion with an electron multiplying charge-coupled device camera, finding excellent agreement with the theoretical analysis.

DOI
10.1103/physreva.88.013816

Related papers

Quantum correlations measured with multi-pixel detectors

Frauke Izdebski

use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-

•Aug 1, 2013•0 citations

Photon-number distributions of twin beams generated in spontaneous parametric down-conversion and measured by an intensified CCD camera

Jan Peřina, Martin Hamar, Václav Michálek +1 more

The measurement of photon-number statistics of fields composed of photon pairs, generated in spontaneous parametric down-conversion and detected by an intensified charge-coupled device (iCCD) camera, is described. Final quantum detection efficiencies, electronic noises, finite numbers of detector pixels, transverse intensity spatial profiles of the detected beams, as well as losses of single photons from a pair are taken into account in a developed general theory of photon-number detection. The measured data provided by an iCCD camera with single-photon detection sensitivity are analyzed along the developed theory. Joint signal-idler photon-number distributions are recovered using the reconstruction method based on the principle of maximum likelihood. The range of applicability of the method is discussed. The reconstructed joint signal-idler photon-number distribution is compared with that obtained by a method that uses superposition of signal and noise and minimizes photoelectron entropy. Statistics of the reconstructed fields are identified to be multimode Gaussian. Elements of the measured as well as the reconstructed joint signal-idler photon-number distributions violate classical inequalities. Sub-shot-noise correlations in the difference of the signal and idler photon numbers as well as partial suppression of odd elements in the distribution of the sum of signal and idler photon numbers are observed.

arXiv:1202.1437•Physical Review A•Feb 14, 2012•70 citations

Full field measurement of spatial correlated photon pairs with an EMCCD camera

M. Edgar, D. S. Tasca, Frauke Izdebski +5 more

The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.

•Jan 1, 2012•0 citations

Optimizing the signal-to-noise ratio in the measurement of photon pairs with detector arrays

Éric Lantz, Paul‐Antoine Moreau, F. Devaux

To evidence multimode spatial entanglement of spontaneous down-conversion, detector arrays allow a full-field measurement, without any a priori selection of the paired photons. We show by comparing results of the recent literature that electron-multiplying CCD cameras allow, in the present state of technology, the detection of quantum correlations with the best signal-to-noise ratio (SNR), while intensified CCD cameras allow at best the identification of pairs. The SNR appears to be proportional to the square root of the number of coherence cells in each image, or Schmidt number. Then corrected estimates are derived for extended coherence cells and not-very-low and non-space-stationary photon fluxes. Finally, experimental measurements of the SNR confirm our model.

arXiv:1407.2455•Physical Review A•Dec 9, 2014•20 citations

General Model of Photon-Pair Detection with an Image Sensor

Hugo Defienne, Matthew C. Reichert, Jason W. Fleischer

We develop an analytic model that relates intensity correlation measurements performed by an image sensor to the properties of photon pairs illuminating it. Experiments using an effective single-photon counting camera, a linear electron-multiplying charge-coupled device camera, and a standard CCD camera confirm the model. The results open the field of quantum optical sensing using conventional detectors.

arXiv:1801.09019•Physical Review Letters•May 17, 2018•83 citations

Coincidence detection of spatially correlated photon pairs with a monolithic time-resolving detector array

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.

arXiv:1609.03419•Optics Express•Dec 5, 2016•34 citations
Intensity correlation measurements form the basis of many experiments based on spontaneous parametric down-conversion. In the most common situation, two single-photon avalanche diodes and coincidence electronics are used in the detection of the photon pairs, and the coincidence count distributions are measured by making use of some scanning procedure. Here we analyze the measurement of intensity correlations using multielement detector arrays. By considering the detector parameters such as the detection and noise probabilities, we found that the mean number of detected photons that maximizes the visibility of the two-photon correlations is approximately equal to the mean number of noise events in the detector array. We provide expressions predicting the strength of the measured intensity correlations as a function of the detector parameters and on the mean number of detected photons. We experimentally test our predictions by measuring far-field intensity correlations of spontaneous parametric down-conversion with an electron multiplying charge-coupled device camera, finding excellent agreement with the theoretical analysis.
use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-
The measurement of photon-number statistics of fields composed of photon pairs, generated in spontaneous parametric down-conversion and detected by an intensified charge-coupled device (iCCD) camera, is described. Final quantum detection efficiencies, electronic noises, finite numbers of detector pixels, transverse intensity spatial profiles of the detected beams, as well as losses of single photons from a pair are taken into account in a developed general theory of photon-number detection. The measured data provided by an iCCD camera with single-photon detection sensitivity are analyzed along the developed theory. Joint signal-idler photon-number distributions are recovered using the reconstruction method based on the principle of maximum likelihood. The range of applicability of the method is discussed. The reconstructed joint signal-idler photon-number distribution is compared with that obtained by a method that uses superposition of signal and noise and minimizes photoelectron entropy. Statistics of the reconstructed fields are identified to be multimode Gaussian. Elements of the measured as well as the reconstructed joint signal-idler photon-number distributions violate classical inequalities. Sub-shot-noise correlations in the difference of the signal and idler photon numbers as well as partial suppression of odd elements in the distribution of the sum of signal and idler photon numbers are observed.
The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.
To evidence multimode spatial entanglement of spontaneous down-conversion, detector arrays allow a full-field measurement, without any a priori selection of the paired photons. We show by comparing results of the recent literature that electron-multiplying CCD cameras allow, in the present state of technology, the detection of quantum correlations with the best signal-to-noise ratio (SNR), while intensified CCD cameras allow at best the identification of pairs. The SNR appears to be proportional to the square root of the number of coherence cells in each image, or Schmidt number. Then corrected estimates are derived for extended coherence cells and not-very-low and non-space-stationary photon fluxes. Finally, experimental measurements of the SNR confirm our model.
We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.