Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1303.6208 · Scientific Reports

Impurities as a quantum thermometer for a Bose-Einstein condensate

Carlos Sabín, Angela White, Lucia Hackermüller, Ivette Fuentes

Published Sep 22, 2014• 89 citations
arXivHTMLPDF

Abstract

We introduce a primary thermometer which measures the temperature of a Bose-Einstein Condensate in the sub-nK regime. We show, using quantum Fisher information, that the precision of our technique improves the state-of-the-art in thermometry in the sub-nK regime. The temperature of the condensate is mapped onto the quantum phase of an atomic dot that interacts with the system for short times. We show that the highest precision is achieved when the phase is dynamical rather than geometric and when it is detected through Ramsey interferometry. Standard techniques to determine the temperature of a condensate involve an indirect estimation through mean particle velocities made after releasing the condensate. In contrast to these destructive measurements, our method involves a negligible disturbance of the system.

DOI
10.1038/srep06436

Related papers

Using Polarons for sub-nK Quantum Nondemolition Thermometry in a Bose-Einstein Condensate

Mohammad Mehboudi, Aniello Lampo, Christos Charalambous +3 more

We introduce a novel minimally disturbing method for sub-nK thermometry in a Bose-Einstein condensate (BEC). Our technique is based on the Bose polaron model; namely, an impurity embedded in the BEC acts as the thermometer. We propose to detect temperature fluctuations from measurements of the position and momentum of the impurity. Crucially, these cause minimal backaction on the BEC and hence, realize a nondemolition temperature measurement. Following the paradigm of the emerging field of quantum thermometry, we combine tools from quantum parameter estimation and the theory of open quantum systems to solve the problem in full generality. We thus avoid any simplification, such as demanding thermalization of the impurity atoms, or imposing weak dissipative interactions with the BEC. Our method is illustrated with realistic experimental parameters common in many labs, thus showing that it can compete with state-of-the-art destructive techniques, even when the estimates are built from the outcomes of accessible (suboptimal) quadrature measurements.

arXiv:1806.07198•Physical Review Letters•Jan 24, 2019•113 citations

Thermometry by correlated dephasing of impurities in a one-dimensional Fermi gas

Sindre Brattegard, Mark T. Mitchison

We theoretically investigate the pure dephasing dynamics of two static impurity qubits embedded within a common environment of ultracold fermionic atoms, which are confined to one spatial dimension. Our goal is to understand how bath-mediated interactions between impurities affect their performance as nonequilibrium quantum thermometers. By solving the dynamics exactly using a functional determinant approach, we show that the impurities become correlated via retarded interactions of the Ruderman-Kittel-Kasuya-Yosida type. Moreover, we demonstrate that these correlations can provide a metrological advantage, enhancing the sensitivity of the two-qubit thermometer beyond that of two independent impurities. This enhancement is most prominent in the limit of low temperature and weak collisional coupling between the impurities and the gas. We show that this precision advantage can be exploited using standard Ramsey interferometry, with no need to prepare correlated initial states or to individually manipulate or measure the impurities. We also quantitatively assess the impact of ignoring these correlations when constructing a temperature estimate, finding that acceptable precision can still be achieved in some parameter regimes using a simplified model of independent impurities. Our results demonstrate the rich nonequilibrium physics of impurities dephasing in a common Fermi gas, and may help to provide better temperature estimates at ultralow temperatures.

arXiv:2307.10132•Physical Review A•Feb 6, 2024•18 citations

Towards enhanced precision in thermometry with nonlinear qubits

Sebastian Deffner

Abstract Quantum thermometry refers to the study of measuring ultra-low temperatures in quantum systems. The precision of such a quantum thermometer is limited by the degree to which temperature can be estimated by quantum measurements. More precisely, the maximal precision is given by the inverse of the quantum Fisher information. In the present analysis, we show that quantum thermometers that are described by nonlinear Schrödinger equations allow for a significantly enhanced precision, that means larger quantum Fisher information. This is demonstrated for a variety of pedagogical scenarios consisting of single and two-qubits systems. The enhancement in precision is indicated by non-vanishing quantum speed limits, which originate in the fact that the thermal, Gibbs state is typically not invariant under the nonlinear equations of motion.

arXiv:2408.16664•Quantum Science and Technology•Jan 20, 2025•9 citations

Direct temperature readout in nonequilibrium quantum thermometry

Yan Xie, Junjie Liu

Quantum thermometry aims to measure temperature in nanoscale quantum systems, paralleling classical thermometry. However, temperature is not a quantum observable, and most theoretical studies have therefore concentrated on analyzing fundamental precision limits set by the quantum Fisher information through the quantum Cramer-Rao bound. In contrast, whether a direct temperature readout can be achieved in quantum thermometry remains largely unexplored, particularly under the nonequilibrium conditions prevalent in real-world applications. To address this, we develop a direct temperature readout scheme based on a thermodynamic inference strategy. The scheme integrates two conceptual developments: (i) By applying the maximum entropy principle with the thermometer's mean energy as a constraint, we assign a reference temperature to the nonequilibrium thermometer. We demonstrate that this reference temperature outperforms a commonly used effective temperature defined through equilibrium analogy. (ii) We obtain positive semi-definite error functions that lower-bound the deviation of the reference temperature from the true temperature-in analogy to the quantum Cramer-Rao bound for the mean squared error-and vanish upon thermalization with the sample. Combining the reference temperature with these error functions, we introduce a notion of corrected dynamical temperature which furnishes a postprocessed temperature readout under nonequilibrium conditions. This corrected dynamical temperature can be evaluated adaptively without prior knowledge of the actual temperature. We validate the corrected dynamical temperature in a qubit-based thermometer under a range of nonequilibrium initial states, confirming its capability to estimate the true temperature. Importantly, we find that increasing quantum coherence can enhance the precision of this readout.

quant-pharXiv:2601.07198•Physical Review A•Jan 13, 2026•1 citation

High precision multi-temperature quantum thermometry via dynamical control

Victor Mukherjee, Analía Zwick, Arnab Ghosh +1 more

We consider a thermometer modelled by a dynamically-controlled multilevel quantum system in contact with a bath. Periodic modulation of the energy level spacings of our quantum thermometer enables us to dramatically increase the accuracy of temperature estimation. As opposed to the diverging relative error near the absolute zero obtained in conventional thermometers, our control scheme enables high precision temperature estimation arbitrarily close to the absolute zero, by maximizing its quantum Fisher information. Alternatively, dynamical control may allow for high-precision measurement of multiple temperatures.

•Nov 27, 2017•4 citations

The Bose polaron as thermometer of a trapped Bose gas: a quantum Monte Carlo study

Tomasz Wasak, Gerard Pascual, Gregory E. Astrakharchik +2 more

Quantum impurities interacting with quantum environments offer unique insights into many-body systems. Here, we explore the thermometric potential of a neutral impurity immersed in a harmonically trapped bosonic quantum gas below the Bose-Einstein condensation critical temperature $T_c$. Using ab-initio Path Integral Monte Carlo simulations at finite temperatures, we analyze the impurity's sensitivity to temperature changes by exploiting experimentally accessible observables such as its spatial distribution. Our results, covering a temperature range of $-1.1 \leqslant T/T_c \leqslant 0.9$, reveal that the impurity outperforms estimations based on a one-species bath at lower temperatures, achieving relative precision of 3-4\% for 1000 measurement repetitions. While non-zero boson-impurity interaction strength $g_{BI}$ slightly reduces the accuracy, the impurity's performance remains robust, especially in the low-temperature regime $T/T_c \lesssim 0.45$ withing the analyzed interaction strengths $0 \leqslant g_{BI}/g \leqslant 5$, where $g$ is the boson-boson coupling. We confirm that quantum optical models can capture rather well the dependence of the temperature sensor on the impurity-gas interaction. Although our findings are in qualitative agreement with previous studies, our Monte Carlo simulations offer improved precision. We find that the maximum likelihood estimation protocol approaches the precision comparable to the limit set by the Quantum Fisher Information bound. Finally, using the Hellinger distance method, we directly extract the Fisher information and find that, by exploiting the extremum order statistics, impurities far from the trap center are more sensitive to thermal effects than those close to the trap center.

arXiv:2503.04553•Mar 6, 2025•0 citations
We introduce a primary thermometer which measures the temperature of a Bose-Einstein Condensate in the sub-nK regime. We show, using quantum Fisher information, that the precision of our technique improves the state-of-the-art in thermometry in the sub-nK regime. The temperature of the condensate is mapped onto the quantum phase of an atomic dot that interacts with the system for short times. We show that the highest precision is achieved when the phase is dynamical rather than geometric and when it is detected through Ramsey interferometry. Standard techniques to determine the temperature of a condensate involve an indirect estimation through mean particle velocities made after releasing the condensate. In contrast to these destructive measurements, our method involves a negligible disturbance of the system.
We introduce a novel minimally disturbing method for sub-nK thermometry in a Bose-Einstein condensate (BEC). Our technique is based on the Bose polaron model; namely, an impurity embedded in the BEC acts as the thermometer. We propose to detect temperature fluctuations from measurements of the position and momentum of the impurity. Crucially, these cause minimal backaction on the BEC and hence, realize a nondemolition temperature measurement. Following the paradigm of the emerging field of quantum thermometry, we combine tools from quantum parameter estimation and the theory of open quantum systems to solve the problem in full generality. We thus avoid any simplification, such as demanding thermalization of the impurity atoms, or imposing weak dissipative interactions with the BEC. Our method is illustrated with realistic experimental parameters common in many labs, thus showing that it can compete with state-of-the-art destructive techniques, even when the estimates are built from the outcomes of accessible (suboptimal) quadrature measurements.
We theoretically investigate the pure dephasing dynamics of two static impurity qubits embedded within a common environment of ultracold fermionic atoms, which are confined to one spatial dimension. Our goal is to understand how bath-mediated interactions between impurities affect their performance as nonequilibrium quantum thermometers. By solving the dynamics exactly using a functional determinant approach, we show that the impurities become correlated via retarded interactions of the Ruderman-Kittel-Kasuya-Yosida type. Moreover, we demonstrate that these correlations can provide a metrological advantage, enhancing the sensitivity of the two-qubit thermometer beyond that of two independent impurities. This enhancement is most prominent in the limit of low temperature and weak collisional coupling between the impurities and the gas. We show that this precision advantage can be exploited using standard Ramsey interferometry, with no need to prepare correlated initial states or to individually manipulate or measure the impurities. We also quantitatively assess the impact of ignoring these correlations when constructing a temperature estimate, finding that acceptable precision can still be achieved in some parameter regimes using a simplified model of independent impurities. Our results demonstrate the rich nonequilibrium physics of impurities dephasing in a common Fermi gas, and may help to provide better temperature estimates at ultralow temperatures.
Abstract Quantum thermometry refers to the study of measuring ultra-low temperatures in quantum systems. The precision of such a quantum thermometer is limited by the degree to which temperature can be estimated by quantum measurements. More precisely, the maximal precision is given by the inverse of the quantum Fisher information. In the present analysis, we show that quantum thermometers that are described by nonlinear Schrödinger equations allow for a significantly enhanced precision, that means larger quantum Fisher information. This is demonstrated for a variety of pedagogical scenarios consisting of single and two-qubits systems. The enhancement in precision is indicated by non-vanishing quantum speed limits, which originate in the fact that the thermal, Gibbs state is typically not invariant under the nonlinear equations of motion.
Quantum thermometry aims to measure temperature in nanoscale quantum systems, paralleling classical thermometry. However, temperature is not a quantum observable, and most theoretical studies have therefore concentrated on analyzing fundamental precision limits set by the quantum Fisher information through the quantum Cramer-Rao bound. In contrast, whether a direct temperature readout can be achieved in quantum thermometry remains largely unexplored, particularly under the nonequilibrium conditions prevalent in real-world applications. To address this, we develop a direct temperature readout scheme based on a thermodynamic inference strategy. The scheme integrates two conceptual developments: (i) By applying the maximum entropy principle with the thermometer's mean energy as a constraint, we assign a reference temperature to the nonequilibrium thermometer. We demonstrate that this reference temperature outperforms a commonly used effective temperature defined through equilibrium analogy. (ii) We obtain positive semi-definite error functions that lower-bound the deviation of the reference temperature from the true temperature-in analogy to the quantum Cramer-Rao bound for the mean squared error-and vanish upon thermalization with the sample. Combining the reference temperature with these error functions, we introduce a notion of corrected dynamical temperature which furnishes a postprocessed temperature readout under nonequilibrium conditions. This corrected dynamical temperature can be evaluated adaptively without prior knowledge of the actual temperature. We validate the corrected dynamical temperature in a qubit-based thermometer under a range of nonequilibrium initial states, confirming its capability to estimate the true temperature. Importantly, we find that increasing quantum coherence can enhance the precision of this readout.
We consider a thermometer modelled by a dynamically-controlled multilevel quantum system in contact with a bath. Periodic modulation of the energy level spacings of our quantum thermometer enables us to dramatically increase the accuracy of temperature estimation. As opposed to the diverging relative error near the absolute zero obtained in conventional thermometers, our control scheme enables high precision temperature estimation arbitrarily close to the absolute zero, by maximizing its quantum Fisher information. Alternatively, dynamical control may allow for high-precision measurement of multiple temperatures.
Quantum impurities interacting with quantum environments offer unique insights into many-body systems. Here, we explore the thermometric potential of a neutral impurity immersed in a harmonically trapped bosonic quantum gas below the Bose-Einstein condensation critical temperature TcT_cTc​. Using ab-initio Path Integral Monte Carlo simulations at finite temperatures, we analyze the impurity's sensitivity to temperature changes by exploiting experimentally accessible observables such as its spatial distribution. Our results, covering a temperature range of −1.1⩽T/Tc⩽0.9-1.1 \leqslant T/T_c \leqslant 0.9−1.1⩽T/Tc​⩽0.9, reveal that the impurity outperforms estimations based on a one-species bath at lower temperatures, achieving relative precision of 3-4\% for 1000 measurement repetitions. While non-zero boson-impurity interaction strength gBIg_{BI}gBI​ slightly reduces the accuracy, the impurity's performance remains robust, especially in the low-temperature regime T/Tc≲0.45T/T_c \lesssim 0.45T/Tc​≲0.45 withing the analyzed interaction strengths 0⩽gBI/g⩽50 \leqslant g_{BI}/g \leqslant 50⩽gBI​/g⩽5, where ggg is the boson-boson coupling. We confirm that quantum optical models can capture rather well the dependence of the temperature sensor on the impurity-gas interaction. Although our findings are in qualitative agreement with previous studies, our Monte Carlo simulations offer improved precision. We find that the maximum likelihood estimation protocol approaches the precision comparable to the limit set by the Quantum Fisher Information bound. Finally, using the Hellinger distance method, we directly extract the Fisher information and find that, by exploiting the extremum order statistics, impurities far from the trap center are more sensitive to thermal effects than those close to the trap center.